Seismic analysis of benchmark building installed with friction dampers

被引:13
作者
Raut, Bhiva R. [1 ]
Jangid, R.S. [1 ]
机构
[1] Department of Civil Engineering, Indian Institute of Technology Bombay, Powai
关键词
benchmark building; earthquake excitation; friction dampers; optimal locations; passive dampers; seismic response; slip force; vibration control;
D O I
10.1080/19373260.2013.840956
中图分类号
学科分类号
摘要
The 20-storey steel building has been declared as seismically excited benchmark building by structural control community to compare various control strategy, such as active, passive, semi-active and combination thereof. In this study, dynamic behaviour of the benchmark building installed with friction damper is investigated. For evaluation of structural responses, the seismic excitations considered are El Cento, Hachinohe, Northridge and Kobe. The friction damper with numerical rectangular ideal elasto-plastic hysteretic model is proposed to be used for the analysis. The effectiveness of friction dampers for reduction of responses namely, displacement, acceleration, base shear and performance criteria stipulated in the benchmark problem is investigated. Since, the activation of friction damper depends on slip force, a parametric study is also conducted to investigate the optimum slip force of the dampers, which yield the minimum responses. Further, optimal placement of dampers, rather than providing the dampers at all the floor levels is also studied, to minimise the cost of the dampers. Numerical study is also carried out by varying the slip force of dampers along the height of the benchmark building. Results show that for appropriate slip force and optimum location number, friction dampers installed in benchmark building can effectively reduce earthquake-induced responses. © 2013 The Institution of Engineers, Singapore.
引用
收藏
页码:20 / 37
页数:17
相关论文
共 19 条
[1]  
Aiken I.D., Kelly J.M., Earthquake Simulator Testing and Analytical Studies of Two Energy-Absorbing Systems for Multi-Storey Structures, Technical Report, UCB, (1990)
[2]  
Battaini M., Casciati F., Faravelli L., Control Algorithm and Sensor Location, Proceedings of the Second World Conference on Structural Control (2WCSC), 2, pp. 1391-1398, (1998)
[3]  
Bhaskarrao A.V., Jangid R.S., Seismic Analysis of Structures Connected with Friction Dampers, Engineering Structures, 28, 5, pp. 690-703, (2006)
[4]  
Bhaskarrao A.V., Jangid R.S., Harmonic Response of Adjacent Structures Connected with Friction Dampers, Journal of Sound and Vibration, 292, 3-5, pp. 710-725, (2006)
[5]  
Constantinou M., Mokha A., Reinhorn A.M., Teflon Bearing in Base Isolation, Part II: Modelling, Journal of Structural Engineering, ASCE, 116, pp. 455-474, (1990)
[6]  
Constantinou M.C., Reinhorn A.M., Mokha A., Watson R., Displacement Control Device for Base Isolation of Bridges, Earthquake Spectra, 7, pp. 179-200, (1991)
[7]  
Dyke S.J., Seismic Protection of a Benchmark Building Using Magneto-Rheological Dampers, Proceedings of the Second World Conference on Structural Control (2WCSC), 2, pp. 1455-1462, (1998)
[8]  
Fukukita A., Saito T., Shiba K., Control Effect for 20-Story Benchmark Building Using Passive or Semi-Active Device, Journal of Engineering Mechanics, 130, 4, pp. 430-436, (2004)
[9]  
Gavin H., Passive Control of the SAC 20 Story Building with Viscous Dampers, Proceedings of the Second World Conference on Structural Control (2WCSC), (1998)
[10]  
Hanson R.D., Soong T.T., Seismic Design with Supplemental Energy Dissipation Devices, Monograph No. 8), (2001)