Study on the refrigeration performance of a miniature pulse tube cryocooler driven by a gas bearing compressor

被引:4
作者
Zhi, Xiaoqin [1 ]
He, Yijing [1 ]
Yang, Zhixiang [1 ]
Zhu, Haifeng [2 ]
Ying, Kongkuai [3 ]
Qiu, Limin [1 ]
机构
[1] Zhejiang Univ, Inst Refrigerat & Cryogen, Hangzhou 310027, Peoples R China
[2] Zilang Sci & Technol City, Nantong Yangtze Delta Acad Intelligent Sensing, Nantong 226000, Peoples R China
[3] Chinese Acad Sci, Shanghai Inst Tech Phys, 500 Yu Tian Rd, Shanghai 200083, Peoples R China
基金
中国国家自然科学基金;
关键词
Miniature pulse tube cryocooler; Gas bearing compressor; Hot end temperature; Intertance tube;
D O I
10.1016/j.applthermaleng.2024.124508
中图分类号
O414.1 [热力学];
学科分类号
摘要
Recent advancements in long-term space exploration, maintenance-free miniature-satellites and drone infrared detections have created a large demand for highly reliable and miniaturized cryocoolers working at 77-150 K. The pulse tube cryocooler (PTC) has no moving part at the cold end, and if driven by a gas bearing linear compressor which has no mechanical fatigue risk, a refrigeration system with high reliability and compactness will be generated. However, very few researches on the cooling performance of PTC driven by gas bearing linear compressor have been reported. In this study, a miniature PTC and gas bearing compressor are developed, with a weight of the whole refrigeration system about 0.97 kg. The maximum cooling capacity reaches 1.73 W at 77 K with input electric power of 66 W. The cooling capacity per unit weight for this cryocooler is 1.78 W/kg at 77 K, which is the highest compared to those of the existing typical miniature cryocoolers, showing its remarkable lower mass for refrigeration. In addition, the influence of the hot end heat dissipation temperature on the cooling performance is studied. It is found that the heat dissipation temperature of the hot end has a significant effect on the cooling performance. For every 10 K decrease in the hot end temperature, the maximum cooling capacity at 77 K increases by 3.45 % to 13.28 %, the relative Carnot efficiency rises by 4.38 % to 12.59 %. Besides, in the miniature PTC, the cooling performance is very sensitive to the length of the inertance tube, even a small change of 10-20 mm on the length of the inertance tube will lead to obvious effect on the optimum frequency and cooling performance of the system. These results will be helpful for the further research and development of the miniature pulse tube cryocoolers.
引用
收藏
页数:6
相关论文
共 22 条
[1]  
Almtireen N., 2022, Diss
[2]  
Filis Avishai, 2009, SPIE, V7298
[3]  
Gedeon D., 2009, Gedeon Associates, V16922
[4]  
Kuo DT, 2006, AIP CONF PROC, V823, P687
[5]   A review of linear compressors for refrigeration [J].
Liang, Kun .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 84 :253-273
[6]  
McKinley I.M., 2016, Cryocoolers, V19, P75
[7]  
Nast TC, 2001, CRYOCOOLERS 11, P145
[8]  
Nguyen T, 2011, Cryocoolers, V16, P97
[9]  
Ouyang Y., 2018, Study on Parameter Matching Between Linear Compressor and Load in High Frequency Pulse Tube Cooler
[10]  
Petach M., 2009, CRYOCOOLERS, V15, P97