> 100 m fiber-coupled microchip laser-induced breakdown spectroscopy for remote elemental analysis applications

被引:0
作者
Batsaikhan, Munkhbat [1 ]
Ohba, Hironori [1 ]
Wakaida, Ikuo [1 ]
机构
[1] Japan Atom Energy Agcy, Collaborat Labs Adv Decommissioning Sci, Naka, Ibaraki 3191195, Japan
来源
OPTICS EXPRESS | 2024年 / 32卷 / 25期
关键词
OPTICAL-FIBER; PEAK POWER; FUEL DEBRIS; RADIATION;
D O I
10.1364/OE.541447
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This study aims to develop ultralong fiber-optic cable (FOC) coupled microchip laser - induced breakdown spectroscopy (mLIBS) to reveal the elemental distribution and local composition of nuclear fuel debris in an accident-damaged reactors at Fukushima Daiichi Nuclear Power Station (FDNPS). Currently at FDNPS, the distance between the area where humans can safely work in a sufficient space and the nuclear fuel debris is expected to be > 100 m. Therefore, it becomes crucial to analyze the light transmittance performance of FOC-coupled mLIBS systems over such long distances in a high-radiation environment. Therefore, this study focuses on the influence of gamma radiation dose and FOC length on the transmittance of the visible and near-infrared (NIR) wavelengths through FOCs. Compared with an FOC with low-OH groups, that with high-OH groups exhibits better light transmittance performance in both wavelength regions in a high-radiation environment. Furthermore, the light transmittance performance of the high-OH FOC extended up to 500 m in length is tested in a radiation-free environment. From the measurement results, the maximum FOC length for microchip crystal oscillation is estimated to be > 800 m, although attenuation is observed with the increase in FOC length. Finally, we analyze the ultralong FOC-coupled mLIBS system through the detection of gadolinium (Gd) in mixed oxide samples. The strong emission lines of Gd were only available in the visible wavelength region. Therefore, quantitative analysis of Gd is successfully performed in the visible region using the mLIBS system coupled with up to 300-m-long FOCs, with the limits of detection being between 0.1% and 0.2%. (c) 2024 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement
引用
收藏
页码:45158 / 45170
页数:13
相关论文
共 38 条
[1]   Simultaneous analysis of gadolinium and surface imaging using a fiber-coupled acoustic wave-assisted microchip LIBS system [J].
Batsaikhan, Munkhbat ;
Ohba, Hironori ;
Karino, Takahiro ;
Akaoka, Katsuaki ;
Wakaida, Ikuo .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (02) :423-432
[2]   Effect of Radiation on the Transmission Rate of Emission Intensity of Optical Fiber Cable Used in a Nuclear Material Facility [J].
Choi, Daewoong ;
Han, Bo-Young ;
Park, Se Hwan ;
Kim, Ho-dong ;
Park, Geun-il ;
Ku, Jeong-Hoe .
NUCLEAR TECHNOLOGY, 2017, 197 (03) :320-328
[3]  
Cremers DA, 2013, HANDBOOK OF LASER-INDUCED BREAKDOWN SPECTROSCOPY, 2ND EDITION, P1, DOI 10.1002/9781118567371
[4]   QUANTITATIVE-ANALYSIS USING REMOTE LASER-INDUCED BREAKDOWN SPECTROSCOPY (LIBS) [J].
DAVIES, CM ;
TELLE, HH ;
MONTOGOMERY, DJ ;
CORBETT, RE .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1995, 50 (09) :1059-1075
[5]   Gamma radiation tests of potential optical fiber candidates for fibroscopy [J].
Deparis, O ;
Megret, P ;
Decreton, M ;
Blondel, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (06) :3027-3031
[6]   Laser-induced breakdown spectroscopy system for remote measurement of salt in a narrow gap [J].
Eto, Shuzo ;
Fujii, Takashi .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2016, 116 :51-57
[7]   RADIATION-INDUCED OPTICAL-ABSORPTION BANDS IN LOW-LOSS OPTICAL FIBER WAVE-GUIDES [J].
FRIEBELE, EJ ;
GINGERICH, ME .
JOURNAL OF NON-CRYSTALLINE SOLIDS, 1980, 38-9 (MAY-) :245-250
[8]   Radiation Effects on Silica-Based Optical Fibers: Recent Advances and Future Challenges [J].
Girard, S. ;
Kuhnhenn, J. ;
Gusarov, A. ;
Brichard, B. ;
Van Uffelen, M. ;
Ouerdane, Y. ;
Boukenter, A. ;
Marcandella, C. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (03) :2015-2036
[9]   Laser ablation plasma expansion using microwaves [J].
Ikeda, Yuji ;
Soriano, Joey Kim ;
Ohba, Hironori ;
Wakaida, Ikuo .
SCIENTIFIC REPORTS, 2023, 13 (01)
[10]   Analysis of gadolinium oxide using microwave-enhanced fiber-coupled micro-laser-induced breakdown spectroscopy [J].
Ikeda, Yuji ;
Soriano, Joey Kim ;
Ohba, Hironori ;
Wakaida, Ikuo .
SCIENTIFIC REPORTS, 2023, 13 (01)