Implementation of shunt active power filter for dynamically distorted load conditions using Goertzel algorithm

被引:0
作者
机构
[1] Dept. of Electrical Engineering, Walchand College of Engineering, Sangli
来源
| 1600年 / IEEE Computer Society卷
关键词
Goertzel Algorithm; harmonics; nonlinear load; Shunt Active Power filter; Thyristor Controlled Reactor; Total Harmonic Distortion;
D O I
10.1109/ICCPCT.2013.6528918
中图分类号
学科分类号
摘要
In this paper the shunt active power filter (SAPF) under varying harmonic conditions is considered. The control technique used for reference current generation consists of Goertzel algorithm. The Goertzel Algorithm calculates the fundamental component of load current under non sinusoidal conditions with high speed and accuracy of response. The variation in harmonics is realized by changing the firing angle of Thyristor Controlled Reactor (TCR). The SAPF can be used for both single phase and 3 phase loads and can directly be connected to utility. The shunt active power filter controlled by Goertzel Algorithm is realized using MATLAB/Simulink. The simulation results meet the IEEE 519- 1992 recommended harmonic standard limits with minimum computations. © 2013 IEEE.
引用
收藏
页码:6 / 11
页数:5
相关论文
共 11 条
[1]  
IEEE Recommended Practices and Requirements F or Harmonic Control in Electrical Power Systems, (1992)
[2]  
Limits for Harmonic Current Emission, (2001)
[3]  
Dugan R.C., McGranaghan M.F., Beaty H.W., Electrical Power System Quality, (1996)
[4]  
Ozdemir E., Ucar M., Kesler M., Kale M., The design and implementation of a shunt active power filter based on source current measurement, The IEEE International Electric Machines and Drives Conference, IEMDC 2007, pp. 608-613, (2007)
[5]  
Peng F.Z., Ott G.W., Adams D.J., Harmonic and reactive power compensation on the generalized instantaneous reactive power theory for three-phase four-wire systems, IEEE Trans. on Power Elec, 13, 6, pp. 1174-1181, (1998)
[6]  
Akagi H., Fujita H., A new power line conditional for harmonic compensation in power systems, IEEE Trans. on Power Del., 10, 3, pp. 1570-1575, (1995)
[7]  
Akagi H., Kanazawa Y., Nabae A., Generalized theory of instantaneous reactive power and its application, Transaction of the IEE Japan, 103, 7 PART B, pp. 483-490, (1983)
[8]  
Akagi H., Watanabe E.H., Aredes M., Instantaneous Power Theory and Applications to Power Conditioning., (2007)
[9]  
Gonzalez S.A., Garcia-Retegui R., Benedetti M., Harmonic computation technique suitable for active power filters, IEEE Trans. on Indu. Electronics, 54, 5, (2007)
[10]  
Hingorani N.G., Gyugi L., Understanding FACTS, (2000)