Distributed data exchange method in condition monitoring system for power transmission and transformation equipment

被引:0
|
作者
Wang, Dewen [1 ]
Yan, Chunyu [2 ]
Bi, Jiangang [2 ]
Yuan, Shuai [2 ]
机构
[1] School of Control and Computer Engineering, North China Electric Power University
[2] China Electric Power Research Institute
来源
Dianli Xitong Zidonghua/Automation of Electric Power Systems | 2012年 / 36卷 / 22期
关键词
Condition acquisition controller; Condition acquisition gateway; Condition monitoring; Simple object access protocol; Web services descriptive language;
D O I
10.3969/j.issn.1000-1026.2012.22.015
中图分类号
学科分类号
摘要
The condition monitoring data exchange between the condition acquisition controller (CAC) and condition acquisition gateway (CAG) is the basis of vertical interconnection of condition information in the condition monitoring system with hierarchical and distributed structure for power transmission and transformation equipment. Based on an analysis of the remote communication protocol for power systems and distributed component technology, the implementation method based on the simple object access protocol (SOAP) of distributed data exchange, the modeling method and process based on Web services descriptive language (WSDL) of data exchange services for condition monitoring are given. A testing system for condition monitoring data exchange based on the above method and model has been developed, and put through performance and load test with the cycle upload service of condition monitoring data for CAC of power transformation equipment as an example. The validity and feasibility of the proposed models and methods have been proved. © 2012 State Grid Electric Power Research Institute Press.
引用
收藏
页码:83 / 88
页数:5
相关论文
共 20 条
  • [1] (2010)
  • [2] Zhang H., Zhu S., Zhang Y., Et al., Research and implementation of condition-based maintenance technology system for power transmission and distribution equipments, Power System Technology, 33, 13, pp. 70-73, (2009)
  • [3] Lin D., Fuchs E.F., Real-time monitoring of iron-core and copper losses of transformers under (non) sinusoidal operation, IEEE Trans on Power Delivery, 21, 2, pp. 1333-1341, (2006)
  • [4] Du L., Wang C., Li X., Et al., A novel power supply of online monitoring systems for power transmission lines, IEEE Trans on Industrial Electronics, 57, 8, pp. 2889-2895, (2010)
  • [5] Xing Y., Zeng Y., Sheng G., Et al., On-line monitoring system of overhead transmission line icing based on mechanical measurement, Automation of Electric Power Systems, 32, 23, pp. 81-85, (2008)
  • [6] Huang X., Zhang Y., Li J., Design of an online monitoring system of dielectric loss in capacitive equipment of substation, High Voltage Engineering, 34, 8, pp. 1594-1598, (2008)
  • [7] Wang D., Zhu Y., Wang Y., Condition monitoring and integrating platform for power transmission and transformation equipment based on IEC 61850, Automation of Electric Power Systems, 34, 13, pp. 43-47, (2010)
  • [8] Zhang J., Guo C., Chao Y., Et al., Substation equipment condition monitoring system and IEC model coordination, Automation of Electric Power Systems, 33, 20, pp. 67-72, (2009)
  • [9] Li X., Liu J., Qin S., Et al., Key technology for power transmission and transformation equipments' online monitoring system based on IEC 61850, High Voltage Engineering, 36, 12, pp. 3041-3046, (2010)
  • [10] (2010)