Calibration of absolute spectral responsivity at 1 064 nm of transfer detector against cryogenic radiometer

被引:0
|
作者
Pang, Weiwei [1 ]
Zheng, Xiaobing [1 ]
Li, Jianjun [1 ]
Shi, Xueshun [2 ]
Wu, Haoyu [1 ]
Xia, Maopeng [1 ]
Gao, Dongyang [1 ]
Shi, Jianmin [1 ]
Qi, Tao [1 ]
Kang, Qing [1 ]
机构
[1] Key Laboratory of Optical Calibration and Characterization, Chinese Academy of Sciences, Hefei,230031, China
[2] The 41st Institute of China Electronics Technology Group Corporation, Qingdao,266555, China
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:3812 / 3818
相关论文
共 50 条
  • [1] Absolute spectral responsivity of silicon trap detector based on absolute cryogenic radiometer
    Shi, Xueshun
    Liu, Changming
    Liu, Yulong
    Yang, Lechen
    Zhao, Kun
    Chen, Haidong
    INTERNATIONAL CONFERENCE ON PHOTONICS AND OPTICAL ENGINEERING (ICPOE 2014), 2015, 9449
  • [2] The technique of measuring absolute spectral responsivity of InGaAs detector based on cryogenic radiometer
    Fan, JH
    Yang, ZJ
    Hou, XQ
    Qin, Y
    Li, ZQ
    2ND INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTICAL TEST AND MEASUREMENT TECHNOLOGY AND EQUIPMENT, PTS 1 AND 2, 2006, 6150
  • [3] Realization of the spectral responsivity scale based on an absolute cryogenic radiometer
    Kee-Suk Hong
    Seongchong Park
    Seung-Kwan Kim
    Seung-Nam Park
    Dong-Hoon Lee
    Journal of the Korean Physical Society, 2015, 67 : 2045 - 2058
  • [4] Realization of the spectral responsivity scale based on an absolute cryogenic radiometer
    Hong, Kee-Suk
    Park, Seongchong
    Kim, Seung-Kwan
    Park, Seung-Nam
    Lee, Dong-Hoon
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (12) : 2045 - 2058
  • [5] Calibration of a trap detector against a cryogenic radiometer
    Nield, KM
    Clare, JF
    Hamlin, JD
    Bittar, A
    METROLOGIA, 1998, 35 (04) : 581 - 586
  • [6] Calibration of a trap detector against a cryogenic radiometer
    Nield, K.M.
    Clare, J.F.
    Hamlin, J.D.
    Bittar, A.
    Metrologia, 35 (04): : 581 - 586
  • [7] Prototype of Cryogenic Solar Absolute Radiometer and Transfer Radiometer for On-Board Calibration of Spectral Earth Imager
    Zajiczek, L.
    Winkler, R.
    Hobson, T.
    Green, P.
    Fox, N.
    13TH INTERNATIONAL CONFERENCE ON NEW DEVELOPMENTS AND APPLICATIONS IN OPTICAL RADIOMETRY, 2018, 972
  • [8] Calibration of photo-detector's absolute spectral responsivity in the wavelength range 300 nm to 1000 nm
    Meng, Haifeng
    Xiong, Limin
    Xu, Nan
    He, Yingwei
    Zhang, Junchao
    Zhang, Bifeng
    2017 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY - OPTOELECTRONIC MEASUREMENT TECHNOLOGY AND SYSTEMS, 2017, 10621
  • [9] Long-Wave Infrared Absolute Spectral Responsivity Scale by Using an Absolute Cryogenic Radiometer
    Liu Hong-bo
    Shi Xue-shun
    Xu Wen-bin
    Liu Chang-ming
    Liu Hong-yuani
    Wang Heng-fei
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40 (12) : 3680 - 3685
  • [10] Measurement of the absolute spectral responsivity in the mid-infrared based on the cryogenic electrical substitution radiometer and an optimized thermopile detector
    Pohl, Tobias
    Meindl, Peter
    Johannsen, Uwe
    Taubert, Dieter
    Werner, Lutz
    JOURNAL OF SENSORS AND SENSOR SYSTEMS, 2019, 8 (01) : 195 - 205