Calibration model of individual optimization in blood glucose measurement using near-infrared spectroscopy

被引:0
作者
Oishi, Keigo [1 ]
Ishizawa, Hiroaki [1 ]
Miyauchi, Yuki [1 ]
Fukuda, Masaya [1 ]
机构
[1] Shinshu University, Japan
来源
Journal of the Illuminating Engineering Institute of Japan (Shomei Gakkai Shi) | 2014年 / 98卷 / 02期
关键词
Blood glucose; Individual; Near-infrared; Non-invasive; Wavelength range;
D O I
10.2150/jieij.98.62
中图分类号
学科分类号
摘要
There has recently been a significant increase in the number of diabetic patients. Self-monitoring of the glucose levels in a patient's blood is essential for treating diabetes. Generally, blood glucose measurement requires an invasive blood sampling. Therefore, patients are always plagued by issues such as pain, stress, and risk of blood-borne infection. The objective of this study is to develop a non-invasive blood glucose measurement device based on NIR spectroscopy. We compared the prediction accuracy of the individual calibration curve and summarized calibration curve, and took the analysis wavelength range into consideration as fundamental experiments for taking a non-invasive blood glucose measurement. As a result, a clinically effective level of accuracy and a high correlation were confirmed in the individual calibration curve, and an analysis using a smaller wavelength range has a good influence on the accuracy.
引用
收藏
页码:62 / 67
页数:5
相关论文
共 12 条
[1]  
Diabetes Programme, (2013)
[2]  
Ferrante Do Amaral C.E., Wolf B., Review Current development in non-invasive glucose monitoring, Medical Engineering & Physics, 30, pp. 541-549, (2008)
[3]  
Kawano S., Fujiwara T., Iwamoto M., Nondestmctive determination of sugar content in satsuma mandarin using near-infrared (N1R) transmittance, Iournal of the Iapanese Society for Horticultural Science, 62, 2, pp. 465-470, (1993)
[4]  
Oliver N.S., Toumazou C., Cass A.E.G., Johnston D.G., Glucose sensors: A review of current and emerging technology, Diabet. Med., 26, 3, pp. 197-210, (2009)
[5]  
Lambert J.L., Morookian J.M., Sirk S.J., Borchert M.S., Measurement of aqueous glucose in a model anterior chamber using Raman spectroscopy, J. Raman Spectrosc., 33, 7, pp. 524-529, (2002)
[6]  
Cameron B.D., Gorde H.W., Satheesan B., Cote G.L., The use of polarized light through the eye for noninvasive glucose monitoring, Diabetes Technol. Therapeut., 1, 2, pp. 135-143, (1999)
[7]  
Heise H.M., Near-Infrared Spectrometry for in Vivo Glucose Sensing in Biosensors in the Body Continuous in Vivo Monitoring, pp. 79-116, (1997)
[8]  
Masuko A., Kusano T., Endo A., Sasagawa Y., Kouno R., Watanabe M., Abe R., Clinical evaluation of improved portable glucose meter Antsense II, Jpn. J. Med. Phann. Sci., 35, pp. 921-928, (1996)
[9]  
Clarke W.L., Cox D., Gondder Frederick L.A., Carter W., Pohl S.L., Evaluating Clinical Accuracy of Systems for Self-Monitoring of Blood Glucose, Diabetes Care, 10, 5, pp. 622-628, (1987)
[10]  
Patterson M.S., Wilson B.C., Wyman D.R., The Propagation of Optical Radiation in Tissue. II: Optical Properties of Tissues and Resulting Fluence Distributions, Laser in Medical Science, 6, pp. 379-390, (1991)