Dynamic analysis for ultra-supercritical boiler water wall considering uneven heat flux distribution and combustion instability

被引:6
作者
Wang, Chao [1 ,2 ]
Chen, Xiangru [1 ]
Liu, Bin [1 ]
Liu, Kairui [1 ]
Han, Yuan [2 ]
Wang, Limin [1 ]
Che, Defu [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, State Key Lab Multiphase Flow Power Engn, Xian, Peoples R China
[2] Inner Mongolia Power Res Inst Co Ltd, Hohhot 010000, Peoples R China
关键词
Coal-fired boiler; Water-cooled wall; Dynamic characteristics; Combustion instability; Steam temperature; Low-load condition; COAL-FIRED POWER; FLOW INSTABILITY; SIMULATION;
D O I
10.1016/j.ijheatmasstransfer.2024.126269
中图分类号
O414.1 [热力学];
学科分类号
摘要
The dynamic characteristics of water-cooled wall are of great significance to the evaluation of the safety and flexibility for the boiler during peak shaving process. However, few dynamic studies considered the uneven heat flux distribution on the water-cooled wall, let alone the variable heat load caused by the combustion instability. In this paper, a segmented dynamic model is developed for the water-cooled wall of a 660 MW ultra supercritical boiler. The model is validated under steady and dynamic working conditions, respectively. Then, the step responses of the steam temperature in different flow loops under different load conditions are comparatively studied under the disturbances of single-parameter changes. In the cases of 10 % step decrease of either the feedwater temperature, the heat load or the feedwater mass flowrate, the outlet steam temperature is influenced greatly by the step decreased feedwater temperature under 100 % BMCR condition, while it is impacted most by the step decreased feedwater mass flow under 50 % THA condition. Under these disturbances, the outlet steam temperature of the tube with higher heat loads has larger variation and longer response time. In addition, the simulated combustion instability by the sinusoidal fluctuating heat load on the water wall is employed to explore the influences of the flame fluctuation amplitude and frequency to the water wall. The maximum steam temperature rises with the increase in amplitude but drops with the frequency of flame fluctuation. The thresholds for the flame fluctuation amplitude and frequency are obtained under different load conditions.
引用
收藏
页数:13
相关论文
共 28 条
[1]  
BERGMAN TL., 2010, Fundamentals of heat and mass transfer, V6th
[2]   Study on the effect of flame offset on water wall tube temperature in 600°C and 700°C ultra-supercritical boiler [J].
Dong, Jiancong ;
Fan, Haojie ;
Wu, Xiaojiang ;
Zhou, Tuo ;
Zhang, Jian ;
Zhang, Zhongxiao .
COMBUSTION SCIENCE AND TECHNOLOGY, 2019, 191 (03) :472-490
[3]   Overall review of peak shaving for coal-fired power units in China [J].
Gu, Yujiong ;
Xu, Jing ;
Chen, Dongchao ;
Wang, Zhong ;
Li, Qianqian .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 54 :723-731
[4]   Prediction of combustion state through a semi-supervised learning model and flame imaging [J].
Han, Zhezhe ;
Li, Jian ;
Zhang, Biao ;
Hossain, Md Moinul ;
Xu, Chuanlong .
FUEL, 2021, 289
[5]   Optimization of operating conditions to achieve combustion stability and reduce NOx emission at half-load for a 550-MW tangentially fired pulverized coal boiler [J].
Jiang, Yu ;
Lee, Byoung-Hwa ;
Oh, Dong-Hun ;
Jeon, Chung-Hwan .
FUEL, 2021, 306
[6]   Dynamic simulation of the water-steam flow in a supercritical once-through boiler [J].
Kim, Seongil ;
Choi, Sangmin .
JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2017, 31 (10) :4965-4975
[7]  
Lee H, 2023, Contribution of Working Groups I, II and III to the Sixth Assessment Report of the Intergovernmental Panel on Climate Change', P5
[8]   Effects of the air-staging degree on performances of a supercritical down-fired boiler at low loads: Air/particle flow, combustion, water wall temperature, energy conversion and NOx emissions [J].
Li, Xiaoguang ;
Zeng, Lingyan ;
Zhang, Ning ;
Chen, Zhichao ;
Li, Zhengqi ;
Qin, Yukun .
FUEL, 2022, 308
[9]   Coupled combustion and hydrodynamics simulation of a 1000MW double-reheat boiler with different FGR positions [J].
Liu, Hu ;
Zhang, Wei ;
Wang, Huan ;
Zhang, Yuanhang ;
Deng, Lei ;
Che, Defu .
FUEL, 2020, 261
[10]   Dynamic performance analysis and control strategy optimization for supercritical coal-fired boiler: A dynamic simulation [J].
Liu, Kairui ;
Wang, Chao ;
Wang, Limin ;
Liu, Bin ;
Ye, Maojing ;
Guo, Yalong ;
Che, Defu .
ENERGY, 2023, 282