Adopting line surge arresters to suppress switching overvoltages in 750 kV EHV transmission lines

被引:0
|
作者
State Key Laboratory of Control and Simulation of Power Systems and Generation Equipment, Department of Electrical Engineering, Tsinghua University, Beijing 100084, China [1 ]
不详 [2 ]
机构
来源
Qinghua Daxue Xuebao | 2008年 / 10卷 / 1545-1548期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] Transmission Line Arresters Application for Control of Switching Overvoltages on 500-kV Transmission Line
    Bunov, P.
    Klingbeil, L.
    Schubert, M.
    Gossler, B.
    Biswas, D.
    Hunt, James
    Thallam, R.
    Keri, A. J. F.
    2014 IEEE PES T&D CONFERENCE AND EXPOSITION, 2014,
  • [2] Power frequency and switching overvoltages of 750 kV AC transmission line
    Liu, Qing
    Zhang, Yu-Feng
    Wan, Geng
    Shi, Wei
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (06): : 1338 - 1343
  • [3] Effect of Different Arresters on Switching Overvoltages in UHV Transmission Lines
    杨鹏程
    陈水明
    何金良
    TsinghuaScienceandTechnology, 2010, 15 (03) : 325 - 328
  • [4] Simulation of Line Surge Arresters for Lightning Protection in 10kV Transmission Lines
    Wang Yong
    Xie Pu
    Zhao Jin-cheng
    Zhang Gui-fang
    2008 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION, VOLS 1 AND 2, 2009, : 269 - +
  • [5] Estimation of Switching Surge Flashover Rate of a 1200 kV UHVAC Transmission Line due to Switching Overvoltages
    Ramchandra Reddy Annadi
    Chandra Sekhar Patsa
    INAE Letters, 2018, 3 (3): : 167 - 174
  • [6] Comparison and Analysis on Key Performance of EHV/UHV DC Transmission Line Surge Arresters
    Gu, Shanqiang
    Wang, Jian
    Wan, Shuai
    Cao, Wei
    He, Jinliang
    2018 34TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP 2018), 2018,
  • [7] Use of line surge arresters for the improvement of the lightning performance of 63 kV and 90 kV shielded and unshielded transmission lines
    Sadovic, S
    Joulie, R
    Tartier, S
    Brocard, E
    IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (03) : 1232 - 1240
  • [8] The Research and Design of Parameters for 750kV Transmission Line Metal-Oxide Surge Arresters with Series Gap
    Wang, Jing
    Wang, Sen
    Guo, Jie
    Cui, Hao
    Gao, Feng
    Hu, Panfeng
    2014 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2014,
  • [9] Application of line surge arresters to double-circuit transmission lines
    Institute of Industrial Science, University of Tokyo, Tokyo, Japan
    不详
    Int. Symp. Light. Prot., XI SIPDA, 2011, (312-318):
  • [10] Statistical Switching Overvoltages of 1200 kV UHV AC Transmission Line
    Annadi R.R.
    Patsa C.S.
    Journal of The Institution of Engineers (India): Series B, 2022, 103 (01) : 189 - 195