Development of a novel automated algorithm for patient dosimetry in computed tomography: a step towards the facilitation of size-specific dose estimates and organs dosimetry estimations in a busy clinical workflow

被引:2
|
作者
Sekkat, Hamza [1 ]
Khallouqi, Abdellah [1 ,2 ]
Madkouri, Youssef [3 ]
El Atifi, Wiam [1 ,4 ]
Rhouch, Imane [1 ]
El Rhazouani, Omar [1 ]
Tahiri, Zakaria [5 ]
Talbi, Mohammed [6 ,7 ]
Halimi, Abdellah [1 ]
机构
[1] Hassan 1st Univ, Higher Inst Hlth Sci, Lab Hlth Sci & Technol, Settat, Morocco
[2] Publ Hosp Mediouna, Dept radiol, Casablanca, Morocco
[3] Ibn Tofail Kenitra Univ, Fac Sci, Lab Elect Syst Informat Proc Mech & Energet, Kenitra, Morocco
[4] Hassan II Univ, Hosp Ctr Ibn Rochd, Fac Med & Pharm, Dept Radiotherapy, Casablanca, Morocco
[5] Abdelmalek Essaadi Univ, Fac Med & Pharm Tangier, Biophys Lab, Life & Hlth Sci Res Lab, Tetouan, Morocco
[6] Minist Hlth & Social Protect, Higher Inst Nursing Profess & Hlth Tech, Rabat, Morocco
[7] Ibn Tofail Univ, Fac Sci, Lab Mat & Subatom Phys, Kenitra, Morocco
关键词
computed tomography; automated algorithm; dosimetry; size-specific dose estimate; organ dose estimation;
D O I
10.1088/1402-4896/ad8b86
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Accurate dosimetry in computed tomography ( CT ) is essential for patient safety and effective radiation management. This study presents the development of an automated algorithm designed to enhance patient dosimetry by facilitating size-specific dose estimates ( SSDE ) and organ dose estimations. Utilizing a Python-based script, the proposed method integrates advanced image preprocessing, contour detection, and mathematical calculations to quantify key metrics from CT images. This automated approach addresses the limitations of manual measurement techniques. A retrospective analysis was conducted on CT axial images from examinations acquired with an 80-detector scanner. The algorithm processes DICOM images, converts pixel values to Hounsfield Units, applies Gaussian smoothing, windowing, and thresholding, followed by morphological operations to refine segmentation. It measures the water equivalent diameter ( Dw ) and estimates both region SSDE and organ doses, incorporating tissue attenuation. Validation was performed using an adult anthropomorphic ATOM phantom, with organ doses measured by optically stimulated luminescence dosimeters. The results demonstrated the algorithm's potential in estimating SSDE and organ doses. Validation of the automated method revealed strong correlations for Dw and SSDE between the proposed method and manual measurements of fi ve expert reviewers ranging from 0.86 to 0.99 for determination coefficient. Comparative analysis of organ doses showed close agreement between results from experimental setup against the proposed algorithm. The automated algorithm estimated brain dose with a mean of 21.8 mGy, while measurements from the ATOM phantom and CT Expo indicated 19.74 mGy and 23.05 mGy, respectively. For lung doses, the automated algorithm estimated 12.5 mGy compared to 11.0 mGy from the ATOM phantom and 13.1 mGy from CT Expo. Liver doses were measured at 12.7 mGy by the automated method, versus 12.1 mGy from the ATOM phantom and 11.1 mGy from CT Expo. This study shows the potential of automated image analysis techniques in enhancing dosimetry accuracy in CT examinations.
引用
收藏
页数:17
相关论文
共 6 条
  • [1] Development of size-specific dose estimates for common computed tomography examinations: a study in Ghana
    Ohene-Botwe, Benard
    Anim-Sampong, Samuel
    Nkansah, Josephine
    JOURNAL OF RADIOLOGICAL PROTECTION, 2023, 43 (01)
  • [2] A Segmentation-based Automated Calculation of Patient Size and Size-specific Dose Estimates in Pediatric Computed Tomography Scans
    Abdulkadir, Muhammad Kabir
    Osman, Noor Diyana
    Achuthan, Anusha
    Nasirudin, Radin A.
    Ahmad, Muhammad Zabidi
    Zain, Noor Hasyima Mat
    Shuaib, Ibrahim Lutfi
    JOURNAL OF MEDICAL PHYSICS, 2024, 49 (03) : 456 - 463
  • [3] Relationship between size-specific dose estimates and image quality in computed tomography depending on patient size
    Kawashima, Hiroki
    Ichikawa, Katsuhiro
    Hanaoka, Shinsuke
    Matsubara, Kosuke
    Takata, Tadanori
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (04): : 246 - 251
  • [4] Effect of table height displacement and patient center deviation on size-specific dose estimates calculated from computed tomography localizer radiographs
    Kazuki Kuriyama
    Kosuke Matsubara
    Shu Hisahara
    Yukie Nagata
    Rumiko Nosaka
    Rika Goto
    Nobutaka Yanano
    Kanichiro Shimizu
    Tomokazu Shoji
    Physical and Engineering Sciences in Medicine, 2020, 43 : 665 - 672
  • [5] Effect of table height displacement and patient center deviation on size-specific dose estimates calculated from computed tomography localizer radiographs
    Kuriyama, Kazuki
    Matsubara, Kosuke
    Hisahara, Shu
    Nagata, Yukie
    Nosaka, Rumiko
    Goto, Rika
    Yanano, Nobutaka
    Shimizu, Kanichiro
    Shoji, Tomokazu
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2020, 43 (02) : 665 - 672
  • [6] Size-specific dose estimates calculated using patient size measurements from scanned projection radiograph in high-resolution chest computed tomography
    Brindhaban, Ajit
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2025, 72 (01) : 85 - 92