A computational workflow for modeling complex patient-specific coronary stenting cases

被引:0
|
作者
Antonini, Luca [1 ,2 ]
Poletti, Gianluca [1 ]
Karanasiou, Georgia S. [3 ,4 ]
Sakellarios, Antonis [3 ,4 ]
Fotiadis, Dimitrios I. [3 ,4 ]
Petrini, Lorenza [5 ]
Pennati, Giancarlo [1 ]
Berti, Francesca [1 ]
机构
[1] Politecn Milan, Lab Biol Struct Mech LaBS, Dept Chem Mat & Chem Engn Giulio Natta, Piazza Leonardo da Vinci 32, I-20133 Milan, Italy
[2] Parametr Design Suisse Sagl, Chiasso, CH, Switzerland
[3] Dept Biomed Res Inst FORTH, Univ Campus Ioannina, Ioannina 45110, Greece
[4] Univ Hosp Ioannina, Dept Cardiol 2, Ioannina 45110, Greece
[5] Politecn Milan, Dept Civil & Environm Engn, Piazza Leonardo da Vinci 32, I-20133 Milan, Italy
关键词
Finite element analysis; Overstretching; Arterial softening; OCT; In silico trial; LEVEL COLLAGEN DAMAGE; MECHANICAL-PROPERTIES; BIFURCATIONS;
D O I
10.1016/j.cmpb.2024.108527
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and objectives: In the era of in silico clinical trials, it is of paramount importance to guarantee simulation reliability. In the field of coronary stenting, there is a need to couple validated stent models with credible digital twins of the arteries, whose mechanical behavior is commonly simplified to guarantee a balance between simulation complexity and computational time, namely usability. To this aim, the current work proposed a phenomenological approach suitable for the mechanical description of patient-specific coronary arteries undergoing coronary stenting in complex cases, e.g. bifurcations, exhibiting overstretching due to procedural choices. Methods: Pre- and post-operative images were used to prepare four vessel models and validate the outcome of multi-step structural stenting simulations in terms of recovered lumen area. Arteries were modeled improving a previous strategy by the authors, namely accounting for different mechanical properties in the media and adventitia layer, with an assigned hyperelastic response with a softening at higher strains to simulate the damage due to overstretching. Plaque components, which were identified from patient images, were classified into lipidic, calcified, and generic, and associated with different properties. Results: The simulation results demonstrated a good match with the clinical outcome of all the stenting procedures, with errors lower than 15 % in terms of recovered lumen area. This proved the reliability of the proposed simulation framework improving the performances of the previous model, making it usable for interpreting also situations where the artery underwent overstretching. Conclusions: The proposed approach allowed to account for the in vivo conditions and have good performance when aiming at describing quantities such as lumen reopening and the presence of malapposed struts following stent deployment.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Towards a Digital Twin of Coronary Stenting: A Suitable and Validated Image-Based Approach for Mimicking Patient-Specific Coronary Arteries
    Poletti, Gianluca
    Antonini, Luca
    Mandelli, Lorenzo
    Tsompou, Panagiota
    Karanasiou, Georgia S.
    Papafaklis, Michail, I
    Michalis, Lampros K.
    Fotiadis, Dimitrios, I
    Petrini, Lorenza
    Pennati, Giancarlo
    ELECTRONICS, 2022, 11 (03)
  • [2] Computational Modelling of Multi-folded Balloon Delivery Systems for Coronary Artery Stenting: Insights into Patient-Specific Stent Malapposition
    Georgios E. Ragkousis
    Nick Curzen
    Neil W. Bressloff
    Annals of Biomedical Engineering, 2015, 43 : 1786 - 1802
  • [3] Computational Modelling of Multi-folded Balloon Delivery Systems for Coronary Artery Stenting: Insights into Patient-Specific Stent Malapposition
    Ragkousis, Georgios E.
    Curzen, Nick
    Bressloff, Neil W.
    ANNALS OF BIOMEDICAL ENGINEERING, 2015, 43 (08) : 1786 - 1802
  • [4] Computational replication of the patient-specific stenting procedure for coronary artery bifurcations: From OCT and CT imaging to structural and hemodynamics analyses
    Chiastra, Claudio
    Wu, Wei
    Dickerhoff, Benjamin
    Aleiou, Ali
    Dubini, Gabriele
    Otake, Hiromasa
    Migliavacca, Francesco
    LaDisa, John F., Jr.
    JOURNAL OF BIOMECHANICS, 2016, 49 (11) : 2102 - 2111
  • [5] Advancements and Opportunities in Characterizing Patient-Specific Wall Shear Stress Imposed by Coronary Artery Stenting
    LaDisa, John F., Jr.
    Ghorbannia, Arash
    Marks, David S.
    Mason, Peter
    Otake, Hiromasa
    FLUIDS, 2022, 7 (10)
  • [6] Comparison of Patient-Specific Computational Modeling Predictions and Clinical Outcomes of LASIK for Myopia
    Seven, Ibrahim
    Vahdati, Ali
    De Stefano, Vinicius Silbiger
    Krueger, Ronald R.
    Dupps, William J., Jr.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (14) : 6287 - 6297
  • [7] A patient-specific numerical modeling of the spontaneous coronary artery dissection in relation to atherosclerosis
    Karimi, Alireza
    Razaghi, Reza
    Koyama, Motomichi
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2019, 182
  • [8] Patient-Specific Three-Dimensional Ultrasound Derived Computational Modeling of the Mitral Valve
    Gediminas Gaidulis
    Kirthana Sreerangathama Suresh
    Dongyang Xu
    Muralidhar Padala
    Annals of Biomedical Engineering, 2022, 50 : 847 - 859
  • [9] Patient-Specific Three-Dimensional Ultrasound Derived Computational Modeling of the Mitral Valve
    Gaidulis, Gediminas
    Suresh, Kirthana Sreerangathama
    Xu, Dongyang
    Padala, Muralidhar
    ANNALS OF BIOMEDICAL ENGINEERING, 2022, 50 (07) : 847 - 859
  • [10] Patient-specific computational modeling of endovascular aneurysm repair: State of the art and future directions
    Avril, Stephane
    Gee, Michael W.
    Hemmler, Andre
    Rugonyi, Sandra
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2021, 37 (12)