Assessment of the lightning performance of compact overhead distribution lines

被引:0
|
作者
机构
[1] University of Bologna, 40122 Bologna
[2] Federal University of Itajubá, Itajubá, 37500-903 Minas Gerais
[3] AES Sul, 93010-060 São Leopoldo, RS, Rua Presidente Roosevelt 68, Centro
来源
Napolitano, F. (fabio.napolitano@unibo.it) | 1600年 / Institute of Electrical Engineers of Japan卷 / 133期
关键词
Electromagnetic transients; Induced overvoltages; Lightning protection; Overhead distribution lines;
D O I
10.1541/ieejpes.133.987
中图分类号
学科分类号
摘要
The assessment of the lightning performance of a compact configuration of MV overhead lines that is expected to be adopted in the near future by an electricity distribution company in a Brazilian region characterized by high keraunic levels is presented. The compact configuration is characterized by the presence of an unenergized wire that has the main function to sustain the spacers of the phase conductors. As the wire could be periodically grounded, the paper analyses its effectiveness in reducing the overvoltages due to indirect lightning. The results are compared with those relevant to a conventional configuration of MV overhead lines now adopted by the same distribution company. The effects of the presence of surge arresters along the line are also analysed. © 2013 The Institute of Electrical Engineers of Japan.
引用
收藏
页码:987 / 993
页数:6
相关论文
共 50 条
  • [1] Statistical Method for the Evaluation of the Lightning Performance of Overhead Distribution Lines
    Mikropoulos, P. N.
    Tsovilis, T. E.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (01) : 202 - 211
  • [2] Comprehensive Assessment of Lightning Protection Schemes for 10 kV Overhead Distribution Lines
    Cao, Jinxin
    Du, Yaping
    Ding, Yuxuan
    Qi, Ruihan
    Li, Binghao
    Chen, Mingli
    Li, Zhe
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (03) : 2326 - 2336
  • [3] Lightning Performance of Overhead Distribution Lines with Underbuilt Ground Wires
    Araneo, R.
    Celozzi, S.
    Brandao Faria, J.
    Andreotti, A.
    Verolino, L.
    2019 INTERNATIONAL APPLIED COMPUTATIONAL ELECTROMAGNETICS SOCIETY SYMPOSIUM (ACES), 2019,
  • [4] Lightning Performance of Overhead Power Distribution Lines in Urban Areas
    Tossani, Fabio
    Borghetti, Alberto
    Napolitano, Fabio
    Piantini, Alexandre
    Nucci, Carlo Alberto
    IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (02) : 581 - 588
  • [5] Lightning Performance of Non-Homogeneus Overhead Distribution Lines
    Soto, E.
    Perez, E.
    2018 34TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP 2018), 2018,
  • [6] Corona Effect Influence on the Lightning Performance of Overhead Distribution Lines
    Mestriner, Daniele
    Brignone, Massimo
    APPLIED SCIENCES-BASEL, 2020, 10 (14):
  • [7] Evaluation of Lightning Attachment and Coupling Models for the Estimation of the Lightning Performance of Overhead Distribution Lines
    Mikropoulos, Pantelis N.
    Tsovilis, Thomas E.
    Pori, Aikaterini S.
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 1212 - 1216
  • [8] Estimation of the Influence of Direct strokes on the Lightning Performance of Overhead Distribution Lines
    Tossani, F.
    Napolitano, F.
    Borghetti, A.
    Nucci, C. A.
    Lopes, G. P.
    Martinez, M. L. B.
    dos Santos, G. J. G.
    2015 IEEE EINDHOVEN POWERTECH, 2015,
  • [9] Statistical Safety Factor in Lightning Performance Analysis of Overhead Distribution Lines
    Sarajcev, Petar
    Lovric, Dino
    Garma, Tonko
    ENERGIES, 2022, 15 (21)
  • [10] Lightning protection of overhead power distribution lines
    Yokoyama, Shigeru
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2007, 2 (05) : 491 - 496