Study on the high-accuracy fluid refractive-index sensor based on an arrayed-waveguide grating

被引:0
作者
Wang, Youbin [1 ]
Huang, Xuguang [1 ]
机构
[1] Laboratory of Photonic Information Technology, South China Normal University, Guangzhou
来源
Guangxue Xuebao/Acta Optica Sinica | 2009年 / 29卷 / 09期
关键词
Arrayed-wavegaide grating (AWG); Fourier optics; Refractive-index; Sensor;
D O I
10.3788/AOS20092909.2378
中图分类号
学科分类号
摘要
A high-accuracy fluid refractive-index sensor based on an arrayed-waveguide grating (AWG) is designed. This system measures the refractive-index of a fluid in the groove using the characteristic of the sensibility of the phase shift of arrayed-waveguides. The phase shifts of the arrayed waveguides (AWs) lead to the position change of the maximum of the light intensity in the image plane of the output slab. The high accuracy real-time refractive-index of the fluid can be obtained from the power rate between two output waveguides via a narrow band source. A mathematical model based on the theory of Fourier optics and wave optics is established with reasonable parameters and the consideration of every factor. The analytic expression of the relationship between the refractive-index of the fluid and the power rate is obtained via fitting. The method can eliminate the instability, the inner loss of the instrument and the measurement error caused by the environment to improve the measurement accuracy of refractive index.
引用
收藏
页码:2378 / 2384
页数:6
相关论文
共 26 条
  • [11] Cho C.H., Urquidi J., Gellene G.I., Et al., Mixture model description of the T-, P dependence of the refractive index of water, J. Chem. Phys., 114, 7, pp. 3157-3162, (2001)
  • [12] Hao D., Wu F., Kong W., Measurement of refractive index of crystals with interferometry, Laser Technology, 27, 5, pp. 407-408, (2003)
  • [13] Uribe M., de Oliveira C.E.M., Clerice J.H., Et al., Measurement of refractive index of GaSb (1.8 to 2.56 μm) using a prism, Electron. Lett., 32, 3, pp. 262-264, (1996)
  • [14] Zhu T., Zhang D., Yang H., Et al., Measurement of refractive index of the crystal with angle of minimum deviation method, J. Synthetic Crystals, 26, 3-4, (1997)
  • [15] Huang Z., He Z., The optical methods for measuring the thickness and refractive index of thin films, Modern Scientific Instrument, 4, 1, pp. 42-44, (2003)
  • [16] Li M., Zhang M., Refractive index measurement by optical fiber Michelson interferometer, Acta Optica Sinica, 20, 9, pp. 1294-1296, (2000)
  • [17] Chu F., Han X., Pang F., Et al., Research development of integrated-optical waveguide sensors, Laser & Optoelectronics Progress, 43, 3, pp. 21-27, (2006)
  • [18] Yoon K.H., Shuler M.L., Kim S.J., Design optimization of nano-grating surface plasmon resonance sensors, Optics Express, 14, 1, pp. 4842-4849, (2006)
  • [19] Qiu H., Liang D., Zhang H., Et al., Research on the surface plasmon resonance fiber optic sensor for cure monitoring, Chinese J. Lasers., A29, 6, pp. 545-549, (2002)
  • [20] Rao Y., Mo Q., Zhu T., A novel-high sensitivity refractive index sensor with temperature self-compensating, Acta Optica Sinica, 26, 2, pp. 264-268, (2006)