Fiber optic chemical sensors for water testing by using fiber loop ringdown spectroscopy technique

被引:0
作者
Kaya M. [1 ]
机构
[1] Eskişehir Osmangazi University, Vocational School of Health Service, Eskişehir
来源
Kaya, Malik (malikkaya@ogu.edu.tr) | 1600年 / Turkiye Klinikleri卷 / 28期
关键词
Chemical trace; Evanescent field; Fiber optic; Fiber optic chemical sensors; Fiber optic sensors; FLRD spectroscopy technique;
D O I
10.3906/ELK-2005-39
中图分类号
学科分类号
摘要
Real-time response, low cost, sensitive and easy setup fiber optic chemical sensors were fabricated by etching a part of single mode fiber in hydrofluoric (HF) acid solution and tested in different water samples such as tap water, DI water, salty and sugar water with different concentrations to record ringdown time (RDT) differences between media due to refractive index differences by employing the fiber loop ringdown (FLRD) spectroscopy technique. Baseline stability of 0.63% and the minimum detectable RDT of 5.05 µs for this kind of fiber optic chemical sensors were obtained. Fabricated sensors were coated with N,N-Diethyl-p-phenylenediamine for the first time and tested in several water solutions. Afterwards, the sensors were immersed into salty and sugar water solutions in different concentrations. The results showed that this kind of FLRDS fiber optic chemical sensors can be applicable to trace chemicals in water solutions. Moreover, fiber optic sensors can be specially modified to trace specifically any target chemicals in solutions for the special purpose and the early detection. © TÜBİTAK
引用
收藏
页码:2375 / 23984
相关论文
共 34 条
  • [1] Ni N, Chan CC, Xia L, Shum P., Fiber cavity ring-down refractive index sensor, IEEE Photonics Technology Letters, 20, pp. 1351-1353, (2008)
  • [2] Wang C, Herath C., High-sensitivity fiber-loop ringdown refractive index sensors using single-mode fiber, Optics Letters, 35, pp. 1629-1631, (2010)
  • [3] Yolalmaz A, Danisman MF, Esenturk O., Discrimination of chemicals via refractive index by EF-FLRD, Applied Physics B, 125, pp. 156-165, (2019)
  • [4] Wang C, Scherrer S., Fiber ringdown pressure sensors, Optics Letters, 29, pp. 352-354, (2004)
  • [5] Wang C, Scherrer S., Fiber loop ringdown for physical sensors development: Pressure sensor, Applied Optics, 43, pp. 6458-6464, (2005)
  • [6] Qiu H, Qiu Y, Chen Z, Fu B, Chen X, Et al., Multimode fiber ring-down pressure sensor, Microwave Optical Technology Letters, 49, pp. 1698-1700, (2007)
  • [7] Zhou W, Wong WC, Chan CC, Shao LY, Dong X., Highly sensitive fiber loop ringdown strain sensor using photonic crystal fiber interferometer, Applied Optics, 50, pp. 3087-3092, (2011)
  • [8] Ghimire M, Wang C., Highly sensitive fiber loop ringdown strain sensor with low temperature sensitivity, Measurement Science Technology, 28, pp. 1051011-10, (2017)
  • [9] Kaya M, Esenturk O., Study of strain measurement by fiber optic sensors with a sensitive fiber loop ringdown spectrometer, Optical Fiber Technology, 54, pp. 1020701-1020707, (2020)
  • [10] Sun B, Shen T, Feng T., Fiber-loop ring-down magnetic field and temperature sensing, Optik, 147, pp. 170-179, (2017)