Development of diffuser/nozzle based valve-less micro-pump

被引:0
作者
Tanaka, Seiichi [1 ]
Tsukamoto, Hiroshi [1 ]
Miyazaki, Koji [1 ]
机构
[1] Graduate School of Life Science and Systems Engineering, Kyushu Institute of Technology, Wakamatsu, Kitakyushu-shi, Fukuoka, 808-0196
来源
Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B | 2008年 / 74卷 / 02期
关键词
Micro-fluidics; Micro-pump; Oscillatory flow; Valve-less micro-pump;
D O I
10.1299/kikaib.74.323
中图分类号
学科分类号
摘要
In this study we have developed a valve-less micro-pump with one diffuser shaped element and a chamber with a diaphragm, the vibration of which produces an oscillating flow. The pressure-loss in a nozzle is lower than that in a diffuser, therefore one-way flow is realized in the nozzle direction. The frequency characteristics and the pump characteristics are measured. The measured maximum total pump head and volumetric flow rate are 0.8 kPa and 2.4 ml/min, respectively. The effect of working-fluid viscosity on pump characteristics is also discussed using water and glycerin-water solutions. As the result, the pump performances were found to be decreased with increasing fluid viscosity and the pump performances depended on the Reynolds number of oscillating flow.
引用
收藏
页码:323 / 328
页数:5
相关论文
empty
未找到相关数据