Electrical Bioimpedance-Based Monitoring of Intracochlear Tissue Changes After Cochlear Implantation

被引:0
|
作者
Sijgers, Leanne [1 ]
Geys, Marlies [1 ]
Geissler, Gunnar [2 ]
Boyle, Patrick [2 ]
Huber, Alexander [1 ]
Pfiffner, Flurin [1 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Dept Otorhinolaryngol Head & Neck Surg, CH-8091 Zurich, Switzerland
[2] Adv Bion GmbH, European Res Ctr, D-30625 Hannover, Germany
关键词
digital biomarkers; remote hearing healthcare; cochlear implant; neuroprosthetics; hearing technology; auditory rehabilitation; HEARING PRESERVATION; IMPEDANCE CHANGES; AUDITORY-NERVE; IN-VITRO; STIMULATION; ELECTRODES; MODEL; ELECTROCOCHLEOGRAPHY; OUTCOMES; HEALTH;
D O I
10.3390/s24237570
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: This study examined electrical bioimpedance as a biomarker for intracochlear tissue changes after cochlear implant surgery, comparing monopolar, three-point, and four-point impedance measurements over time and evaluating different measurement systems and approaches. Methods: Impedance measurements were obtained from 21 participants during surgery and at four postoperative stages. Monopolar impedances were recorded using the Bionic Ear Data Collection System (BEDCS) and the Active Insertion Monitoring (AIM) system. Three- and four-point impedances were recorded directly using BEDCS, and indirect three-point impedances were additionally derived from Electrical Field Imaging matrices recorded using BEDCS or AIM. Results: There was an 11% relative error between monopolar measurements from BEDCS and AIM and a 25% discrepancy between direct and indirect three-point measurements. Despite this, direct and indirect measurements from both systems were useful for tracking postoperative impedance shifts. Three- and four-point measurements showed a strong relationship both during and after surgery. Our results suggest that three- and four-point measurements are more specific than monopolar impedances in capturing localized tissue changes. Conclusions: Three- and four-point impedance measurements are potential markers of intracochlear tissue changes over time. While direct three-point impedance measurements offer higher accuracy, indirect measurements provide a feasible alternative for monitoring intracochlear changes in clinical settings lacking the option of direct measurements.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Application of extra- and intracochlear electrocochleography during and after cochlear implantation
    Dalbert, Adrian
    Weder, Stefan
    HNO, 2025, 73 (01) : 14 - 21
  • [2] Does the audiogram shape influence the intracochlear recording of Electrocochleography during and after cochlear implantation?
    Haumann, Sabine
    Timm, Max E.
    Buechner, Andreas
    Lenarz, Thomas
    Salcher, Rolf B.
    FRONTIERS IN NEUROSCIENCE, 2025, 18
  • [3] Correlation between word recognition score and intracochlear new bone and fibrous tissue after cochlear implantation in the human
    Kamakura, Takefumi
    Nadol, Joseph B., Jr.
    HEARING RESEARCH, 2016, 339 : 132 - 141
  • [4] Insertional depth-dependent intracochlear pressure changes in a model of cochlear implantation
    Mittmann, Marlene
    Ernst, Arneborg
    Mittmann, Philipp
    Todt, Ingo
    ACTA OTO-LARYNGOLOGICA, 2017, 137 (02) : 113 - 118
  • [5] Spread of the intracochlear electrical field: Implications for assessing electrode array location in cochlear implantation
    Soderqvist, Samuel
    Sivonen, Ville
    Koivisto, Juha
    Aarnisalo, Antti
    Sinkkonen, Saku T.
    HEARING RESEARCH, 2023, 434
  • [6] Contribution of macrophages to neural survival and intracochlear tissue remodeling responses following cochlear implantation
    Rahman, Muhammad Taifur
    Mostaert, Brian J.
    Hunger, Bryce
    Saha, Utsow
    Claussen, Alexander D.
    Razu, Ibrahim
    Nasrin, Farjana
    Khan, Nashwaan Ali
    Eckard, Peter
    Coleman, Sarah
    Oleson, Jacob
    Kirk, Jonathon R.
    Hirose, Keiko
    Hansen, Marlan R.
    JOURNAL OF NEUROINFLAMMATION, 2023, 20 (01)
  • [7] Pneumolabyrinth, intracochlear and vestibular fluid loss after cochlear implantation
    Moteki, Hideaki
    Fujinaga, Yasunari
    Goto, Tetsuya
    Usami, Shin-ichi
    AURIS NASUS LARYNX, 2018, 45 (05) : 1116 - 1120
  • [8] Cochlear Implantation in Vestibular Schwannoma Surgery: Diagnostic Accuracy Analysis of Intraoperative Monitoring with Intracochlear Electrode
    Zanoletti, Elisabetta
    Concheri, Stefano
    Tealdo, Giulia
    Cazzador, Diego
    Fiasca, Valerio M. Di Pasquale
    Franchella, Sebastiano
    Impala, Giuseppe
    Brotto, Davide
    OTOLOGY & NEUROTOLOGY, 2025, 46 (04) : 437 - 445
  • [9] Quality Control after Intracochlear Intralabyrinthine Schwannoma Resection and Cochlear Implantation
    Sudhoff, Holger
    Scholtz, Lars Uwe
    Gehl, Hans Bjoern
    Todt, Ingo
    BRAIN SCIENCES, 2021, 11 (09)
  • [10] Monitoring Cochlear Health With Intracochlear Electrocochleography During Cochlear Implantation: Findings From an International Clinical Investigation
    O'Leary, S.
    Mylanus, E.
    Venail, F.
    Lenarz, T.
    Birman, C.
    Di Lella, F.
    Roland Jr, J. T.
    Gantz, B.
    Beynon, A.
    Sicard, M.
    Buechner, A.
    Lai, W. K.
    Boccio, C.
    Choudhury, B.
    Tejani, V. D.
    Plant, K.
    English, R.
    Arts, R.
    Bester, C.
    EAR AND HEARING, 2023, 44 (02) : 358 - 370