Numerical research on geothermal energy extraction in backfilled mines by using the excellent heat transfer performance of loop heat pipe

被引:0
|
作者
Wang, Xueli [1 ]
Zhang, Pengju [2 ]
Dong, Xuquan [1 ]
Wang, Jingyu [1 ]
Fang, Jiabin [3 ]
Zhang, Xiaoyan [1 ]
Liu, Lang [1 ,4 ]
机构
[1] Xian Univ Sci & Technol, Sch Energy Engn, Xian 710054, Shaanxi, Peoples R China
[2] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Xian 710049, Shaanxi, Peoples R China
[3] Xi An Jiao Tong Univ, Sch Chem Engn & Technol, Xian 710049, Shaanxi, Peoples R China
[4] Minist Educ China, Key Lab Western Mines & Hazards Prevent, Xian 710054, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Backfill mining; Loop heat pipe; Orthogonal test; Vapor-liquid two phase flow; Heat storage/heat release; MASS-TRANSFER; CYLINDRICAL EVAPORATOR; FLAT EVAPORATOR; SIMULATION;
D O I
10.1016/j.icheatmasstransfer.2024.108385
中图分类号
O414.1 [热力学];
学科分类号
摘要
Deep mine harbor substantial geothermal energy. Integrating a heat exchanger within the backfill body mitigates thermal hazards and facilitates the concurrent extraction of mineral and geothermal resources. Inspired by the capabilities of superior thermal conductivity, high heat transfer limit without additional energy consumption of loop heat pipe (LHP), a novel cemented paste backfill system coupled with an LHP heat exchanger (LHPHE-CPB) was developed to effectively improve the thermal conductivity of backfill body and enhance the extraction performance of geothermal energy in backfilled mines. The temperature evolutions of LHPHE-CPB system and the mechanisms of vapor-liquid phase transition and two-phase flow within LHP were numerically analyzed during the stages of heat storage and simultaneous heat storage/heat release. Orthogonal tests meticulously examined the effects of surrounding rock temperature, and the inlet temperature and flow rate of cooling water on the system's heat transfer performance. Optimal operating conditions for the system, in terms of reducing backfill body temperature, achieving favorable temperature differentials between the inlet and outlet cooling water, and enhancing the heat extraction capacity of system, were determined through range and variance analyses. This research establishes a theoretical foundation for the application of LHP in efficiently extracting geothermal energy from backfilled mines.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Numerical and experimental study of geothermal heat extraction from backfilled mine stopes
    Ghoreishi-Madiseh, S. A.
    Hassani, F.
    Abbasy, F.
    APPLIED THERMAL ENGINEERING, 2015, 90 : 1119 - 1130
  • [2] Test and analysis on heat transfer performance of the loop heat pipe
    Jiang, F.-M. (jiangfm@ms.giec.ac.c), 1688, Board of Optronics Lasers, No. 47 Yang-Liu-Qing Ying-Jian Road, Tian-Jin City, 300380, China (24):
  • [3] Experimental study on the heat transfer performance of a loop heat pipe
    Wang, Yi-Wei
    Cen, Ji-Wen
    Zhu, Xiong
    Jiang, Fang-Ming
    Liu, Pei
    Guangdianzi Jiguang/Journal of Optoelectronics Laser, 2012, 23 (08): : 1458 - 1462
  • [4] Numerical and experimental study of transient conjugate heat transfer in helical closed-loop geothermal heat exchangers for application of thermal energy storage in backfilled mine stopes
    Templeton, Jeffrey D.
    Ghoreishi-Madiseh, Seyed Ali
    Hassani, Ferri P.
    Sasmito, Agus P.
    Kurnia, Jundika C.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2020, 44 (12) : 9609 - 9616
  • [5] Heat leak effects on the heat transfer performance of a flat loop heat pipe
    Mo, Dong-Chuan
    Ding, Nan
    Lü, Shu-Shen
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2010, 31 (09): : 1513 - 1515
  • [6] Numerical investigation on heat extraction performance of an open loop geothermal system in a single well
    Wang, Gaosheng
    Song, Xianzhi
    Shi, Yu
    Sun, Baojiang
    Zheng, Rui
    Li, Jiacheng
    Pei, Zhijun
    Song, Hengyu
    GEOTHERMICS, 2019, 80 : 170 - 184
  • [7] Experimental Study on Heat Transfer Performance of Elliptical Loop Heat Pipe
    Wu, Guoqiang
    Gou, Xiang
    Li, Bo
    PROCEEDINGS OF 2019 IEEE 3RD INTERNATIONAL ELECTRICAL AND ENERGY CONFERENCE (CIEEC), 2019, : 1591 - 1596
  • [8] IMPROVEMENT OF HEAT TRANSFER PERFORMANCE OF LOOP HEAT PIPE FOR ELECTRONIC DEVICES
    Takamatsu, Tomonao
    Hisano, Katsumi
    Iwasaki, Hideo
    PROCEEDINGS OF THE ASME PACIFIC RIM TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC SYSTEMS, MEMS AND NEMS 2011, VOL 2, 2012, : 165 - +
  • [9] STUDY OF THE HEAT TRANSFER PERFORMANCE OF A LOOP HEAT PIPE WITH ALUMINUM WICK
    Lin, Bingyao
    Xie, Rongjian
    Tao, Leren
    THERMAL SCIENCE, 2022, 26 (02): : 1379 - 1390
  • [10] Effect of secondary wick on heat transfer performance of a loop heat pipe
    Liu, Le
    Jiang, Zhenhua
    Lin, Binyao
    shao, Bo
    Li, Nanxi
    Dong, Deping
    Wu, Yinong
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2025, 208