Electromagnetic compatibility testing of implantable neurostimulators exposed to metal detectors

被引:3
|
作者
Seidman S.J. [1 ]
Kainz W. [1 ]
Casamento J. [1 ]
Witters D. [1 ]
机构
[1] Food and Drug Administration (FDA), Center for Devices and Radiological Health (CDRH), Silver Spring, MD 20910
来源
关键词
EMC; EMI; Implantable neurostimulators; Metal detectors;
D O I
10.2174/1874120701004010063
中图分类号
学科分类号
摘要
This paper presents results of electromagnetic compatibility (EMC) testing of three implantable neurostimulators exposed to the magnetic fields emitted from several walk-through and hand-held metal detectors. The motivation behind this testing comes from numerous adverse event reports involving active implantable medical devices (AIMDs) and security systems that have been received by the Food and Drug Administration (FDA). EMC testing was performed using three neurostimulators exposed to the emissions from 12 walk-through metal detectors (WTMDs) and 32 hand-held metal detectors (HHMDs). Emission measurements were performed on all HHMDs and WTMDs and summary data is presented. Results from the EMC testing indicate possible electromagnetic interference (EMI) between one of the neurostimulators and one WTMD and indicate that EMI between the three neurostimulators and HHMDs is unlikely. The results suggest that worst case situations for EMC testing are hard to predict and testing all major medical device modes and setting parameters are necessary to understand and characterize the EMC of AIMDs. © Seidman et al.; Licensee Bentham Open.
引用
收藏
页码:63 / 70
页数:7
相关论文
共 50 条
  • [1] Electromagnetic compatibility of implantable neurostimulators to RFID emitters
    Pantchenko, Oxana S.
    Seidman, Seth J.
    Guag, Joshua W.
    Witters, Donald M., Jr.
    Sponberg, Curt L.
    BIOMEDICAL ENGINEERING ONLINE, 2011, 10
  • [2] Electromagnetic compatibility of implantable neurostimulators to RFID emitters
    Oxana S Pantchenko
    Seth J Seidman
    Joshua W Guag
    Donald M Witters
    Curt L Sponberg
    BioMedical Engineering OnLine, 10
  • [3] Electromagnetic Compatibility Implantable Pacemaker Testing
    Hajovsky, Radovan
    Penhaker, Marek
    Capek, Ondrej
    Cernohorsky, Jindrich
    Skapa, Jan
    Korpas, David
    KNOWLEDGE IN TELECOMMUNICATION TECHNOLOGIES AND OPTICS 2010 (KTTO 2010), 2010, : 176 - 179
  • [4] Hand-held metal detectors and medical devices: Measurements and testing for electromagnetic compatibility
    Witters, DM
    Buzduga, V
    Seidman, S
    Kainz, W
    Casamento, J
    Ruggera, P
    39TH ANNUAL 2005 INTERNATIONAL CARNAHAN CONFERENCE ON SECURITY TECHNOLOGY, PROCEEDINGS, 2005, : 312 - 314
  • [5] Implantable cardiac pacemaker electromagnetic compatibility testing in a novel security system simulator
    Kainz, W
    Casamento, JP
    Ruggera, PS
    Chan, DD
    Witters, DM
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (03) : 520 - 530
  • [6] Medical implantable devices and electromagnetic compatibility
    Andrivet, P
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 2003, 96 : 57 - 64
  • [7] Adhoc electromagnetic compatibility testing of non-implantable medical devices and radio frequency identification
    Seidman, Seth J.
    Guag, Joshua W.
    BIOMEDICAL ENGINEERING ONLINE, 2013, 12
  • [8] Adhoc electromagnetic compatibility testing of non-implantable medical devices and radio frequency identification
    Seth J Seidman
    Joshua W Guag
    BioMedical Engineering OnLine, 12
  • [9] Electromagnetic Compatibility Analysis of RFID and Implantable Medical Devices
    Spano, Ivan Luigi
    Serpi, Alessandro
    Fanti, Alessandro
    Nissardi, Vincenzo
    Lai, Andrea
    Caredda, Francesco Valentino
    Orru, Pier Francesco
    Mazzarella, Giuseppe
    Marongiu, Ignazio
    Gatto, Gianluca
    2014 22ND TELECOMMUNICATIONS FORUM TELFOR (TELFOR), 2014, : 818 - 821
  • [10] A framework of automatic testing system for electromagnetic compatibility
    Cao Cheng
    Su Donglin
    Dai Fei
    2007 4TH INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY PROCEEDING: EMC 2007, 2007, : 279 - 283