Research implementing unibody clamp anchors and a simple mechanical stressing device to post-tension external, unbonded carbon fiber-reinforced polymer (CFRP) rods is presented. The experiments described in the paper concern three prestressed concrete beams: one was used as the control beam and the other two were damaged. Damage consisted of cracked concrete that was removed and internal steel tendons that were cut to simulate vehicle collision, corrosion, or both. The repair system was then applied to the two damaged concrete beams. The CFRP repair system performed well, increasing the ultimate strength and flexural capacity of the damaged beams to meet or exceed the strength capacity of the control. An analytical model considering the tendon stress at ultimate and the distribution of internal forces was developed to explore design recommendations for the use of the unibody clamp anchors and stressing device for post-tensioning CFRP rods. Copyright © 2014, American Concrete Institute.
引用
收藏
页码:387 / 395
页数:8
相关论文
共 12 条
  • [1] AASHTO LRFD Bridge Design Specifications, (2009)
  • [2] Abdel Aziz M., Abdel-Sayed G., Ghrib F., Grace N., Madugula M., Analysis of concrete beams prestressed and post-tensioned with externally unbonded carbon fiber reinforced polymer tendons, Canadian Journal of Civil Engineering, 31, pp. 1138-1151, (2005)
  • [3] Abdelrahman A.A., Tadros G., Rizkalla S.H., Test model for the first Canadian smart highway bridge, ACI Structural Journal, 92, 4, pp. 451-458, (1995)
  • [4] Prestressing Concrete Structures with FRP Tendons (ACI 440.4R-04) (Reapproved 2011), (2004)
  • [5] Guide Test Methods for Fiber-reinforced Polymer (FRP) Composites for Reinforcing Or Strengthening Concrete and Masonry Structures (ACI 440.3R-12), (2012)
  • [6] Aravinthan T., Mutsuyoshi H., Fujioka A., Hishiki Y., Prediction of the ultimate flexural strength of externally prestressed PC beams, Transactions of the Japan Concrete Institute, 19, pp. 225-230, (1997)
  • [7] Burningham C., Development of a Carbon Fiber Reinforced Polymer Prestressing System for Structural Applications, (2011)
  • [8] El-Hacha R., Elbadry M., Strengthening concrete beams with externally prestressed carbon fiber composite cables: Experimental investigation, PTI Journal, 4, 2, pp. 53-70, (2006)
  • [9] Elrefai A., West J., Soudki K., Strengthening of RC beams with external post-tensioned CFRP tendons, Case Histories and use of FRP for Prestressing Applications, pp. 123-142, (2007)
  • [10] Naaman A., Alkhairi F., Stress at ultimate in unbonded post-tensioning tendons: Part 2-proposed methodology, ACI Structural Journal, 88, 6, pp. 683-692, (1991)