Analysis of simulation model parameters and transition time based on MATLAB for magnetically-saturated controllable reactor

被引:2
|
作者
Tian, Mingxing [1 ]
Yang, Xuesong [1 ]
Gu, Shengjie [1 ]
Yuan, Dongsheng [1 ]
机构
[1] Lanzhou Jiaotong University
来源
Dianli Zidonghua Shebei/Electric Power Automation Equipment | 2013年 / 33卷 / 06期
关键词
Computer simulation; Controllable reactor; Electric reactors; Magnetic saturation; MATALB; Transition time;
D O I
10.3969/j.issn.1006-6047.2013.06.009
中图分类号
学科分类号
摘要
Modeling method and transition time calculation are two important issues in the research of magnetically-saturated controllable reactor. According to the saturation characteristics of magnetically-saturated controllable reactor and by analyzing the small slope magnetization characteristic curve, the quantitative relationship among its rated capacity, rated voltage, turns ratio and winding resistance is obtained and the way for setting the parameters of simulation model based on MATLAB is presented. The small slope magnetization characteristic curve is piecewise linearized to divide the transition from no-load to full-load into two processes: the DC flux increases linearly with time and the control current varies according to the charge law of a linear RL circuit, based on which, a more accurate formula of transition time calculation is derived. Case simulation confirms the effectiveness of the presented analysis method.
引用
收藏
页码:47 / 51
页数:4
相关论文
共 17 条
  • [1] Golovchan V.D., Dorozhko L.L., Serokin V.M., Comparison of controllable reactor and thyristor devices, Elektrotekhanika, 65, 1, pp. 28-36, (1994)
  • [2] Aleksandrov G.N., Kashina V.A., Lisochina T.V., Economic efficiency of AC power transmission with controlled shunt reactors, Elektrotekhanika, 62, 2, pp. 6-11, (1991)
  • [3] Belyaev A.N., Smolovik S.V., Steady-state and transient stability of 500 kV long-distance AC transmission lines with magnetically controlled shunt reactors, 2005 IEEE Power Tech Conference, pp. 1-6, (2005)
  • [4] Zhou Q., Guo Q., Bu G., Et al., Application of controllable reactors in China's power grid at extra and ultra voltage level, Proceedings of the CSEE, 27, 7, pp. 1-6, (2007)
  • [5] Huang X., Shi H., Tian C., Reactive power and voltage control based on MCR in substations, Electric Power Automation Equipment, 31, 8, pp. 99-102, (2011)
  • [6] Tian M., Li Q., Magnetic saturation type and transformer type controllable shunt reactor, High Voltage Engineering, 29, 7, pp. 26-27, (2003)
  • [7] Zhang L., Xu Y., Application and development of shunt reactors in EHV & UHV transmission lines, Electric Power Automation Equipment, 27, 4, pp. 75-78, (2007)
  • [8] (2005)
  • [9] Deng Z., Wang X., Zhou F., Et al., Modeling of extra-high voltage magnetically controlled shunt reactor, Proceedings of the CSEE, 28, 36, pp. 108-113, (2008)
  • [10] Wang X., Deng Z., Yu K., Et al., Steady-state characteristics of extra-high voltage magnetically controlled shunt reactor, Proceedings of the CSEE, 28, 33, pp. 104-109, (2008)