220/20 kV power supply scheme in high load density urban areas

被引:0
|
作者
Huang, Lei [1 ]
Cheng, Hao-Zhong [1 ]
Ouyang, Wu [1 ]
Yao, Bai-Sha [2 ]
Wu, Zheng [2 ]
Dong, Zhen-Wei [2 ]
机构
[1] Dept of Electrical Engineering, Shanghai Jiaotong University, Shanghai 200240, China
[2] Wuxi Power Supply Company, Wuxi 214001, China
关键词
Graphic methods - Electric power transmission networks - Urban planning;
D O I
暂无
中图分类号
学科分类号
摘要
Application of 20 kV in MV distribution system has been proved to be feasible and advisable with the rapid growing load density in urban areas. The decreasing of gap between neighboring voltage value in the existing 220/110/20 kV sequence results in overlapping in power supply area and that the capacity of devices in system cannot be in full use subsequently. Assuming the load in the area is uniformly distributed, this paper proposes a mathematical model with a decision-making index based on power supply cost per unit load and makes a Voronoi diagram based 220 kV substation optimal supply area. A case study of a real distribution system in Jiangsu province is employed to make a comparison of the cost per unit load in the horizontal year in both 220/110/20 kV and 220/20 kV system. Preliminary conclusion about reasonable load density of higher than a certain level is appropriate for voltage sequence in power supply system in special conditions is presented. And it also makes a further suggestion that 110kV be eliminated from the existing voltage sequence in urban distribution system with this load density for avoiding overlapping in voltage stepping down and also getting ready for further HV distribution voltage optimization.
引用
收藏
页码:1 / 6
相关论文
共 50 条
  • [1] Total Supply Capability Analysis of Urban 220 kV Area Power System Considering Load Transfer Capability of HV Distribution Network
    Zhang X.
    Liu Y.
    Lü L.
    Jin Y.
    Liu J.
    Liu R.
    Dianwang Jishu/Power System Technology, 2017, 41 (05): : 1612 - 1618
  • [2] Research on the Fault Isolation Scheme for Power Supply Lines of 20 kV Railway Loop Network
    铁路20 kV环网电力供电线路故障隔离方案研究
    Fan, Rui-Dong, 2018, Editorial Department of Journal of Railway Engineering Society, China (35)
  • [3] Security Risk Assessment of Electricity Supply at 220/110/20 kV Sardanesti Power Substation from Romania
    Fita, Nicolae Daniel
    Radu, Sorin Mihai
    Marcu, Marius Daniel
    2023 INTERNATIONAL SYMPOSIUM ON FUNDAMENTALS OF ELECTRICAL ENGINEERING, ISFEE 2023, 2023, : 712 - +
  • [4] Inrush current restraint scheme of power transformer over 220 kV
    Guangxi University, Nanning 530004, China
    不详
    Dianli Zidonghua Shebei Electr. Power Autom. Equip., 2008, 12 (48-51+55):
  • [5] Power Quality Assessment System for a 220 kV/110 kV High Voltage Power Station
    Iacobici-Luca, Nicolae
    Frigura-Iliasa, Flaviu Mihai
    Vatau, Doru
    Andea, Petru
    10TH INTERNATIONAL CONFERENCE 2016 ELECTRIC POWER QUALITY AND SUPPLY RELIABILITY CONFERENCE (PQ), 2016, : 267 - 272
  • [6] Improving power supply capability of 220 kV district grid using 500 kV main transformer with high short circuit impedance
    Jiangsu Electric Power Company, Nanjing 210024, China
    不详
    Dianli Xitong Zidonghue, 2008, 14 (96-98):
  • [7] Electrical Insulation Packaging for a 20 kV High Density Wide Bandgap Power Module
    Tousi, Maryam Mesgarpour
    Ghassemi, Mona
    2019 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2019, : 4162 - 4166
  • [8] Simulation Study of 220kV Power Grid Partition and the Mutual Supply Mode
    Yang, Nan
    Zhou, Bao-yu
    Yuan, Qing-fang
    Ma, Heng-rui
    Sun, Jian
    Li, Ya-dong
    Wang, Hai-yun
    Zhu, Shao-min
    INTERNATIONAL CONFERENCE ON ELECTRICAL, CONTROL AND AUTOMATION ENGINEERING (ECAE 2013), 2013, : 399 - 407
  • [9] Load Modeling for 220kV Power Station Based on Statistical Synthesis Method
    Xu, Jian
    Huang, Lei
    Zhang, Jian
    Sun, Yuanzhang
    POWER AND ENERGY ENGINEERING CONFERENCE 2010, 2010, : 539 - 542
  • [10] Study on 220 kV switchgear scheme for Huizhou and Qianwan Nature Gas Power Plant
    Lin, You-Hui