Three phase short circuit fault transient analysis of wind farm installed with DFIG wind turbine system

被引:0
|
作者
Department of Thermal Engineering, Tsinghua University, Beijing 100084, China [1 ]
不详 [2 ]
机构
关键词
Dynamic models - MATLAB - Transient analysis;
D O I
暂无
中图分类号
学科分类号
摘要
Three phase short circuit fault transient analysis of wind farm installed with DFIG wind turbine system deals with the impact between the wind farm and electrical network. First, based on theoretical analysis, a dynamic model of wind turbine system and power grid were built. Then, applying Matlab/Simulink to parameters of the system, the simulation model of wind farm was programmed. Finally, with the digital simulation and analysis, the transient characteristics of key parameters of the wind farm and wind turbine unit were discussed. The built model and simulation results provided the theoretical basis of research of the impact between the wind farm and the electrical network.
引用
收藏
页码:141 / 144
相关论文
共 50 条
  • [1] An Equivalent Method for the Fault Circuit Current Analysis of DFIG Wind Farm
    Xu, Hua
    Zhao, Ping
    Zhao, Yutong
    Wei, Xuhui
    Liu, Jinjie
    Wang, Tongtong
    Zheng, Tao
    PROCEEDINGS OF 2017 CHINA INTERNATIONAL ELECTRICAL AND ENERGY CONFERENCE (CIEEC 2017), 2017, : 343 - 350
  • [2] Transient stability of DFIG wind turbines at an external short-circuit fault
    Sun, T
    Chen, Z
    Blaabjerg, F
    WIND ENERGY, 2005, 8 (03) : 345 - 360
  • [3] Transient analysis of grid short circuit fault of megawatt doubly fed wind turbine
    Lü, Zhi-Qiang
    Xu, Guo-Dong
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (23): : 112 - 116
  • [4] Three-phase symmetrical short-circuit current characteristics analysis of wind turbine driven DFIG with crowbar protection
    Zhai, Jiajun
    Zhang, Buhan
    Xie, Guanglong
    Mao, Chengxiong
    Wang, Kui
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2013, 37 (03): : 18 - 23
  • [5] Short-Circuit Current Analysis for DFIG Wind Farm Considering the Action of a Crowbar
    Yuan, Yan Hong
    Wu, Feng
    ENERGIES, 2018, 11 (02)
  • [6] Analysis of Short Circuit Faults in a System Fed by Wind Turbine
    Nayir, Ahmet
    Rosolowski, Eugeniusz
    Jedut, Leszek
    INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA), 2012,
  • [7] Transient Characteristics Analysis of DFIG-based Wind Turbine Under Symmetrical Voltage Fault
    Ling Y.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2022, 42 (18): : 6871 - 6879
  • [8] DFIG-based Wind Farm Equivalent Model for Power System Short Circuit Current Calculation
    Cui Yang
    Yan Gan-gui
    Jiang Da-wei
    Zhou Zhi-qiang
    Wang Xiao-bo
    Li Qiang
    2009 INTERNATIONAL CONFERENCE ON SUSTAINABLE POWER GENERATION AND SUPPLY, VOLS 1-4, 2009, : 1517 - +
  • [9] Evaluation and analysis of transient current of a DFIG wind generation system under grid fault
    Li, Hui
    Zhao, Meng
    Ye, Ren-Jie
    Tang, Xian-Hu
    Liu, Zhi-Xiang
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2010, 14 (08): : 45 - 51
  • [10] Analysis of Short-circuit Characteristics and Calculation of Steady-state Short-circuit Current for DFIG Wind Turbine
    Xiaofu XIONGJinxin OUYANG State Key Laboratory of Power Transmission Equipment and System Security Chongqing UniversityChongqing China
    电力系统自动化, 2012, 36 (08) : 115 - 121