Reliability of trap-filling parameters read from OSL dose-response curves measured by procedures with sensitivity correction

被引:0
作者
Pawlak, Natalia K. [1 ]
Chruscinska, Alicja [1 ]
机构
[1] Nicolaus Copernicus Univ Torun, Inst Phys Astron & Informat, Grudziadzka 5, PL-87100 Torun, Poland
关键词
Dose response; Optically stimulated luminescence; Computer modelling; Double saturating exponential; Single saturating exponential; STIMULATED LUMINESCENCE; QUARTZ;
D O I
10.1016/j.radphyschem.2024.112365
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
As is known from the early stimulated luminescence studies, dose-response curves (DRCs) are not consistent with the curves of the dependence of the electron concentration in the traps on the irradiation dose delivered to a crystal, even for a system consisting of one trap and one recombination centre. However, for the optically stimulated luminescence (OSL) signal originating from more complex trap and recombination centre systems, it is often observed that the DRC can be described by a simple single saturating exponential (SSE) or a double saturating exponential (DSE) function. Using simulations, we show that although good fit compliance can often be achieved, the parameters obtained only in some cases correctly describe the relationship between the occupancy of individual traps and the dose. Simulations performed for the DRC construction procedure included a step allowing for the correction of possible changes in sensitivity. A model of two traps active in the OSL process and two recombination centres was tested. The modelling shows that the results of the DRC analysis using SSE functions strongly depend not only on the relationship of the trapping probability coefficients of traps but also on their concentrations and the concentrations of recombination centres. The shape of the DRC, and therefore the fitting parameters, also change with the annealing temperature used in the DRC measurement protocol.
引用
收藏
页数:13
相关论文
共 16 条
[1]   Towards a general kinetic model for optically and thermally stimulated luminescence of quartz [J].
Bailey, RM .
RADIATION MEASUREMENTS, 2001, 33 (01) :17-45
[2]   Luminescence thermochronometry of feldspar minerals: Optimisation of measurement conditions for the derivation of thermal kinetic parameters using isothermal holding experiments [J].
Bouscary, C. ;
King, G. E. .
QUATERNARY GEOCHRONOLOGY, 2022, 67
[3]   SUPER-LINEAR FILLING OF TRAPS IN CRYSTALS DUE TO COMPETITION DURING IRRADIATION [J].
BOWMAN, SGE ;
CHEN, R .
JOURNAL OF LUMINESCENCE, 1979, 18-9 (JAN) :345-348
[4]   Natural and laboratory TT-OSL dose response curves: Testing the lifetime of the TT-OSL signal in nature [J].
Chapot, M. S. ;
Roberts, H. M. ;
Duller, G. A. T. ;
Lai, Z. P. .
RADIATION MEASUREMENTS, 2016, 85 :41-50
[5]   A comparison of natural- and laboratory-generated dose response curves for quartz optically stimulated luminescence signals from Chinese Loess [J].
Chapot, M. S. ;
Roberts, H. M. ;
Duller, G. A. T. ;
Lai, Z. P. .
RADIATION MEASUREMENTS, 2012, 47 (11-12) :1045-1052
[6]   A new look at the models of the superlinear dose dependence of thermoluminescence [J].
Chen, R ;
Fogel, G ;
Lee, CK .
RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) :63-68
[7]   Northward migration of the eastern Himalayan syntaxis revealed by OSL thermochronometry [J].
King, Georgina E. ;
Herman, Frederic ;
Guralnik, Benny .
SCIENCE, 2016, 353 (6301) :800-804
[8]   Sublinear dose dependence of thermoluminescence and optically stimulated luminescence prior to the approach to saturation level [J].
Lawless, J. L. ;
Chen, R. ;
Pagonis, V. .
RADIATION MEASUREMENTS, 2009, 44 (5-6) :606-610
[9]  
McKeever S.W.S., 2022, A Course in Luminescence Measurements and Analyses for Radiation Dosimetry
[10]   Superlinearity revisited: A new analytical equation for the dose response of defects in solids, using the Lambert W function [J].
Pagonis, Vasilis ;
Kitis, George ;
Chen, Reuven .
JOURNAL OF LUMINESCENCE, 2020, 227