Lightning overvoltage withstand of a ±800 kV smoothing reactor

被引:0
|
作者
Chen, Shuiming [1 ]
Yang, Pengcheng [1 ]
Gen, Yinan [1 ]
Wu, Yukun [2 ]
机构
[1] State Key Lab of Control and Simulation of Power Systems and Generation Equipments, Department of Electrical Engineering, Tsinghua University, Beijing 100084, China
[2] Beijing Power Equipment Group, Beijing 102401, China
关键词
Electrolysis - HVDC power transmission;
D O I
暂无
中图分类号
学科分类号
摘要
±800 kV smoothing reactors are necessary in ±800 kV high voltage direct current (HVDC) transmission. Before manufacturing the reactor, the lightning overvoltage withstand ability of the reactor should be evaluated to ensure that the voltage between each pair of coils is less than the critical value. The voltage distribution in such a reactor was analyzed with PSCAD/EMTDC. The results show that the external coils' over-voltage between the two first coils is larger than between the internal coils with higher voltages during cut-off lightning than with the full lightning.
引用
收藏
页码:23 / 26
相关论文
共 50 条
  • [41] Influence of lightning induced voltage on lightning withstand level of transmission lines
    Hou, Mu-Wu
    Zeng, Rong
    He, Jin-Liang
    Power System Technology, 2004, 28 (12) : 46 - 49
  • [42] Overvoltage and lightning protection components in telecommunications
    Murko, V
    INFORMACIJE MIDEM-JOURNAL OF MICROELECTRONICS ELECTRONIC COMPONENTS AND MATERIALS, 1995, 25 (03): : 218 - 225
  • [43] Risk evaluation in lightning and overvoltage protection
    Tatár, Dénes
    Periodica Polytechnica Electrical Engineering, 2000, 44 (02): : 201 - 212
  • [44] Experimental Observed Lightning Surge Overvoltage at the Secondary Side of the 220 kV Potential Transformer and Current Transformer
    Cao, Jinxin
    Wang, Jianguo
    Cai, Li
    Zhou, Mi
    Fan, Yadong
    Xu, Changfeng
    Chu, Wangxiang
    2024 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATIONS, ICHVE 2024, 2024,
  • [45] LIGHTNING OVERVOLTAGE PROTECTION OF THE DRAKENSBERG 420 KV SF6 GAS-INSULATED SUBSTATION
    ECKLIN, G
    ROBINSON, P
    SCHLICHT, D
    BROWN BOVERI REVIEW, 1982, 69 (06): : 188 - 195
  • [46] Research on lightning surge overvoltage of convertor station with 500 kV hot-standby circuit breakers
    Fan, Youping
    Wu, Lihui
    Qiu, Huimin
    Wen, Wu
    Liu, Songkai
    Qian, Hai
    Chen, Dong
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2015, 9 (07) : 900 - 907
  • [47] Study on transferred lightning overvoltage in microgrid
    Yu, Hongqiao
    Chen, Shuiming
    Yang, Pengcheng
    2010 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY & TECHNICAL EXHIBITION ON EMC RF/MICROWAVE MEASUREMENTS & INSTRUMENTATION, 2010, : 1550 - 1553
  • [48] ELECTRIC STRENGTH OF ARRESTER FOR LIGHTING SHIELDING OF 6-35 KV TRANSMMCSION LINE WITH LIGHTNING OVERVOLTAGE
    Belskiy, R. A.
    Frolov, V. Y.
    Podporkin, G. V.
    JOURNAL OF MINING INSTITUTE, 2018, 232 : 401 - 406
  • [49] Simulation and Analysis of Operating Overvoltage of AC System at ±800 kV Converter Station Based on EMTS/EMTPE
    Ren, Zheng
    Fan, Jiaqi
    Chen, Xiaolu
    Gao, He
    Lu, Jianqiang
    Zheng, Bowen
    ADVANCES IN ARTIFICIAL SYSTEMS FOR MEDICINE AND EDUCATION II, 2020, 902 : 729 - 737
  • [50] Methods for testing the lightning withstand of aircraft equipment
    Borisov, R.K.
    Grigor'ev, O.A.
    Larionov, V.P.
    Elektrichestvo, 1993, (07): : 21 - 27