摘要
±800 kV smoothing reactors are necessary in ±800 kV high voltage direct current (HVDC) transmission. Before manufacturing the reactor, the lightning overvoltage withstand ability of the reactor should be evaluated to ensure that the voltage between each pair of coils is less than the critical value. The voltage distribution in such a reactor was analyzed with PSCAD/EMTDC. The results show that the external coils' over-voltage between the two first coils is larger than between the internal coils with higher voltages during cut-off lightning than with the full lightning.
引用
收藏
页码:23 / 26
相关论文
共 50 条
  • [21] Research on Lightning Overvoltage and Comprehensive lightning proof measures of 10kV Overhead Insulated Distribution Lines
    Han Xuemin
    Mao Minghua
    Wu Jianbin
    Zhou Wenjun
    Yu Jianhui
    Tu jun
    Wang Xiaofeng
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 4035 - +
  • [22] Overvoltage Simulation Analysis and Suppression of Breaking in a 35 kV Shunt Reactor
    Chen, Jing
    Chen, Xiaoyue
    Feng, Siying
    Liu, Xinmeng
    Liu, Qin
    ENERGIES, 2025, 18 (05)
  • [23] TRANSIENT LIGHTNING OVERVOLTAGE PROTECTION REQUIREMENTS FOR A 500 KV GAS-INSULATED SUBSTATION
    CRONIN, JC
    COLCLASER, RG
    LEHMAN, RF
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1978, 97 (01): : 68 - 78
  • [24] Transient identification of lightning strokes on ±800 kV UHVDC transmission lines
    Liu, Kezhen
    Shu, Hongchun
    Yu, Jilai
    Tian, Xincui
    Wu, Weimin
    Dianwang Jishu/Power System Technology, 2013, 37 (11): : 3007 - 3014
  • [25] Protection against lightning and overvoltage
    Schamber, Andreas
    Konstruktion, 2015, 67 (04): : 34 - 35
  • [26] Overvoltage withstand test of wires of low voltage facility
    Zhu, Wenbing
    Wang, Jianguo
    Wu, Zhiyong
    Ren, Hairong
    Gaodianya Jishu/High Voltage Engineering, 2002, 28 (07):
  • [27] Calculation and Analysis of Internal Overvoltage of 500 kV High Coupled Split Reactor
    Mo, Wenxiong
    Wu, Kaijian
    Yuan, Zhao
    Chen, Lixue
    Liu, Junxiang
    Zhu, Lu
    Gaodianya Jishu/High Voltage Engineering, 2021, 47 (02): : 495 - 503
  • [28] Comparison and Analysis on Very Fast Transient Overvoltage Based on 550kV GIS and 800kV GIS
    Tian Chi
    Lin Xin
    Xu Jianyuan
    Geng Zhen-xin
    ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION, 2008, : 288 - 291
  • [29] LIGHTNING OVERVOLTAGE PROTECTION OF THE PADDOCK 362-145 KV GAS-INSULATED SUBSTATION
    ELAHI, H
    SUBLICH, M
    ANDERSON, ME
    NELSON, BD
    IEEE TRANSACTIONS ON POWER DELIVERY, 1990, 5 (01) : 144 - 150
  • [30] Lightning Impulse Corona Characteristic of 1000-kV UHV Transmission Lines and Its Influences on Lightning Overvoltage Analysis Results
    Yang, Pengcheng
    Chen, Shuiming
    He, Jinliang
    IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (04) : 2518 - 2525