Properties of rigid-pile composite foundation based on FDM-PFM coupling method

被引:0
作者
机构
[1] School of Civil Engineering and Transportation, South China University of Technology, Guangzhou 510640, Guangdong
[2] State Key Laboratory of Subtropical Building Science, South China University of Technology, Guangzhou 510640, Guangdong
来源
Han, X.-L. (xlhan@scut.edu.cn) | 1600年 / South China University of Technology卷 / 42期
关键词
Cushion; FDM-PFM coupling method; Negative pile shaft friction; Penetration; Pile-to-soil stress ratio; Rigid-pile composite foundation;
D O I
10.3969/j.issn.1000-565X.2014.06.014
中图分类号
学科分类号
摘要
In order to reveal the mechanical nature of granular cushion and deeply investigate the effect of granular cushion on the performance of rigid-pile composite foundation, a finite differential-particle flow (FDM-PFM) coupling method is proposed, and a coupling model for the static loading test of a single rigid-pile composite foundation is set up. Then, the calculation results are compared with the in-situ test results of a composite foundation of a high-rise building, with good accordance being found, which means that the proposed coupling method is effective, and that the macro and micro parameters are properly selected. Finally, further simulations are performed to analyze the effects of different cushion materials on the properties of rigid-pile composite foundation. The results show that (1) with the increase of cushion stiffness, the settlement decreases, the pile-to-soil stress ratio increases, and the penetration of the pile top into the cushion decreases; (2) the range of negative skin friction area of the pile is determined as follows: 0.30 L of medium and coarse sand, 0.25 L of crushed stone, and 0.20 L of graded sand and stone; and (3) with the increase of cushion stiffness, the negative skin friction decreases, while the axial force of the pile increases.
引用
收藏
页码:88 / 95
页数:7
相关论文
共 20 条
[1]  
Li N., Han X., Study on mechanism of cushion in composite pile foundation, China Civil Engineering Journal, 34, 2, pp. 68-73, (2001)
[2]  
Qi K.-J., Zai J.-M., Mei G.-X., Et al., Numerical analysis on effects of cushion of composite foundation with pile group, Chinese Journal of Rock Mechanics and Engineering, 23, 1, pp. 4590-4592, (2004)
[3]  
Huang S.-G., Test study and finite element analysis of CFG composite foundation, Rock and Soil Mechanics, 29, 5, pp. 1275-1279, (2008)
[4]  
Zhou A.-J., Li B., Experimental study and finite element analysis of cushion in CFG pile composite foundation, Rock and Soil Mechanics, 31, 6, pp. 1803-1808, (2010)
[5]  
Zheng J.-J., Chen J., Luo H.-B., Et al., Analyzing failure modes and appropriate thickness of the cushion on rigid pile composite ground, Journal of Huazhong University of Science and Technology: Nature Science Edition, 36, 7, pp. 120-123, (2008)
[6]  
Qi L., Shi J.-Y., Cao Q., Method for calculating rational thickness of cushion in rigid pile composite ground, Rock and Soil Mechanics, 30, 11, pp. 3423-3428, (2009)
[7]  
Qi L., Shi J.-Y., Hou Q., Research on pile penetration into cushion of composite ground, Rock and Soil Mechanics, 32, 3, pp. 815-819, (2011)
[8]  
Ren P., Deng R.-G., Yu Z.-Q., Experimental research on composite foundations with CFG piles, Rock and Soil Mechanics, 29, 1, pp. 81-86, (2008)
[9]  
Zheng G., Liu S.-J., Wu Z.-C., Study on behavior of rigid pile composite ground with different cushion thicknesses, Rock and Soil Mechanics, 27, 8, pp. 1357-1360, (2006)
[10]  
Qi L., Wang Q.-S., Qu N., Model test on the depth of pile penetration into the cushion of composite foundation, Journal of Yangtze River Scientific Research Institute, 29, 8, pp. 125-128, (2012)