Stimulated echo acquisition mode (STEAM) diffusion tensor imaging with different diffusion encoding times in the supraspinatus muscle: Test-retest reliability and comparison to spin echo diffusion tensor imaging

被引:0
|
作者
Marth, Adrian Alexander [1 ,2 ]
Sommer, Stefan [1 ,3 ]
Feiweier, Thorsten [4 ]
Sutter, Reto [2 ,5 ]
Nanz, Daniel [1 ,5 ]
von Deuster, Constantin [1 ,3 ]
机构
[1] Balgrist Campus AG, Swiss Ctr Musculoskeletal Imaging SCMI, Zurich, Switzerland
[2] Balgrist Univ Hosp, Dept Radiol, Zurich, Switzerland
[3] Siemens Healthineers Int AG, Adv Clin Imaging Technol, Zurich, Switzerland
[4] Siemens Healthineers AG, Erlangen, Germany
[5] Univ Zurich UZH, Med Fac, Zurich, Switzerland
关键词
diffusion tensor imaging; muscle; stimulated Echo; EXERTIONAL COMPARTMENT SYNDROME; HUMAN SKELETAL-MUSCLE; 3.0; T; RELAXATION; CALF; REPEATABILITY; TRACKING; MRI; T-2; DTI;
D O I
10.1002/nbm.5279
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Diffusion tensor imaging (DTI) provides insight into the skeletal muscle microstructure and can be acquired using a stimulated echo acquisition mode (STEAM)-based approach to quantify time-dependent tissue diffusion. This study examined diffusion metrics and signal-to-noise ratio (SNR) in the supraspinatus muscle obtained with a STEAM-DTI sequence with different diffusion encoding times (Delta) and compared them to measures from a spin echo (SE) sequence. Ten healthy subjects (mean age 31.5 +/- 4.7 years; five females) underwent 3-Tesla STEAM and SE-DTI of the shoulder in three sessions. STEAM was acquired with Delta of 100/200/400/600 ms. The diffusion encoding time in SE scans was 19 ms (b = 500 s/mm(2)). Region of interest-based measurement of fractional anisotropy (FA), mean diffusivity (MD), and SNR was performed. Intraclass correlation coefficients (ICCs) were computed to assess test-retest reliability. ANOVA with post-hoc pairwise tests was used to compare measures between different Delta of STEAM as well as STEAM and SE, respectively. FA was significantly higher (FA(STEAM): 0.38-0.46 vs. FA(SE): 0.26) and MD significantly lower (MDSTEAM: 1.20-1.33 vs. MDSE: 1.62 x 10(-3) mm(2)/s) in STEAM compared to SE (p < 0.001, respectively). SNR was significantly higher for SE (72.3 +/- 8.7) than for STEAM (p < 0.001). ICCs were excellent for FA in STEAM (>= 0.911) and SE (0.960). For MD, ICCs were good for STEAM(100ms-600ms) (>= 0.759) and SE (0.752). STEAM and SE exhibited excellent reliability for FA and good reliability for MD in the supraspinatus muscle. SNR was significantly higher in SE compared to STEAM.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Peripheral Nerve Diffusion Tensor ImagingInterreader and Test-retest Reliability as Quantified by the Standard Error of Measurement
    Fabian Preisner
    Philipp Bäumer
    Michaela Wehrstein
    Birgit Friedmann-Bette
    Matthes Hackbusch
    Sabine Heiland
    Martin Bendszus
    Moritz Kronlage
    Clinical Neuroradiology, 2020, 30 : 679 - 689
  • [42] Feasibility of Diffusion Tensor Imaging at 1.5T Using Multi-Band Echo Planar Acquisition
    Mitsuda, Minoru
    Suzuki, Yuichi
    Kunimatsu, Akira
    Kasahara, Akihiro
    Watanabe, Yasushi
    Ino, Kenji
    Yano, Keiichi
    Ohtomo, Kuni
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2017, 16 (02) : 169 - 175
  • [43] Direct comparison of in-vivo and post-mortem spin-echo based diffusion tensor imaging in the porcine heart
    Christian T Stoeck
    Constantin von Deuster
    Nikola Cesarovic
    Martin Genet
    Maximilian Y Emmert
    Sebastian Kozerke
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [44] Diffusion tensor imaging of the human optic nerve using a non-CPMG fast spin echo sequence
    Chabert, S
    Molko, N
    Cointepas, Y
    Le Roux, P
    Le Bihan, D
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (02) : 307 - 310
  • [45] Diffusion tensor imaging of human Achilles tendon by stimulated echo readout-segmented EPI (ste-RS-EPI)
    Wengler, Kenneth
    Tank, Dharmesh
    Fukuda, Takeshi
    Paci, James M.
    Huang, Mingqian
    Schweitzer, Mark E.
    He, Xiang
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (06) : 2464 - 2474
  • [46] Determining skeletal muscle architecture with Laplacian simulations: a comparison with diffusion tensor imaging
    Geoffrey G. Handsfield
    Bart Bolsterlee
    Joshua M. Inouye
    Robert D. Herbert
    Thor F. Besier
    Justin W. Fernandez
    Biomechanics and Modeling in Mechanobiology, 2017, 16 : 1845 - 1855
  • [47] Diffusion-weighted imaging in the prostate: an apparent diffusion coefficient comparison of half-Fourier acquisition single-shot turbo spin-echo and echo planar imaging
    Babourina-Brooks, Ben
    Cowin, Gary J.
    Wang, Deming
    MAGNETIC RESONANCE IMAGING, 2012, 30 (02) : 189 - 194
  • [48] Determining skeletal muscle architecture with Laplacian simulations: a comparison with diffusion tensor imaging
    Handsfield, Geoffrey G.
    Bolsterlee, Bart
    Inouye, Joshua M.
    Herbert, Robert D.
    Besier, Thor F.
    Fernandez, Justin W.
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2017, 16 (06) : 1845 - 1855
  • [49] Diffusion time dependency along the human corpus callosum and exploration of age and sex differences as assessed by oscillating gradient spin-echo diffusion tensor imaging
    Tetreault, Pascal
    Harkins, Kevin D.
    Baron, Corey A.
    Stobbe, Rob
    Does, Mark D.
    Beaulieu, Christian
    NEUROIMAGE, 2020, 210
  • [50] Microscopic imaging of slow flow and diffusion: A pulsed field gradient stimulated echo sequence combined with turbo spin echo imaging
    Scheenen, TWJ
    Vergeldt, FJ
    Windt, CW
    de Jager, PA
    Van As, H
    JOURNAL OF MAGNETIC RESONANCE, 2001, 151 (01) : 94 - 100