Stimulated echo acquisition mode (STEAM) diffusion tensor imaging with different diffusion encoding times in the supraspinatus muscle: Test-retest reliability and comparison to spin echo diffusion tensor imaging

被引:0
|
作者
Marth, Adrian Alexander [1 ,2 ]
Sommer, Stefan [1 ,3 ]
Feiweier, Thorsten [4 ]
Sutter, Reto [2 ,5 ]
Nanz, Daniel [1 ,5 ]
von Deuster, Constantin [1 ,3 ]
机构
[1] Balgrist Campus AG, Swiss Ctr Musculoskeletal Imaging SCMI, Zurich, Switzerland
[2] Balgrist Univ Hosp, Dept Radiol, Zurich, Switzerland
[3] Siemens Healthineers Int AG, Adv Clin Imaging Technol, Zurich, Switzerland
[4] Siemens Healthineers AG, Erlangen, Germany
[5] Univ Zurich UZH, Med Fac, Zurich, Switzerland
关键词
diffusion tensor imaging; muscle; stimulated Echo; EXERTIONAL COMPARTMENT SYNDROME; HUMAN SKELETAL-MUSCLE; 3.0; T; RELAXATION; CALF; REPEATABILITY; TRACKING; MRI; T-2; DTI;
D O I
10.1002/nbm.5279
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Diffusion tensor imaging (DTI) provides insight into the skeletal muscle microstructure and can be acquired using a stimulated echo acquisition mode (STEAM)-based approach to quantify time-dependent tissue diffusion. This study examined diffusion metrics and signal-to-noise ratio (SNR) in the supraspinatus muscle obtained with a STEAM-DTI sequence with different diffusion encoding times (Delta) and compared them to measures from a spin echo (SE) sequence. Ten healthy subjects (mean age 31.5 +/- 4.7 years; five females) underwent 3-Tesla STEAM and SE-DTI of the shoulder in three sessions. STEAM was acquired with Delta of 100/200/400/600 ms. The diffusion encoding time in SE scans was 19 ms (b = 500 s/mm(2)). Region of interest-based measurement of fractional anisotropy (FA), mean diffusivity (MD), and SNR was performed. Intraclass correlation coefficients (ICCs) were computed to assess test-retest reliability. ANOVA with post-hoc pairwise tests was used to compare measures between different Delta of STEAM as well as STEAM and SE, respectively. FA was significantly higher (FA(STEAM): 0.38-0.46 vs. FA(SE): 0.26) and MD significantly lower (MDSTEAM: 1.20-1.33 vs. MDSE: 1.62 x 10(-3) mm(2)/s) in STEAM compared to SE (p < 0.001, respectively). SNR was significantly higher for SE (72.3 +/- 8.7) than for STEAM (p < 0.001). ICCs were excellent for FA in STEAM (>= 0.911) and SE (0.960). For MD, ICCs were good for STEAM(100ms-600ms) (>= 0.759) and SE (0.752). STEAM and SE exhibited excellent reliability for FA and good reliability for MD in the supraspinatus muscle. SNR was significantly higher in SE compared to STEAM.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] The b matrix in diffusion tensor echo-planar imaging
    Mattiello, J
    Basser, PJ
    LeBihan, D
    MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (02) : 292 - 300
  • [22] Second-Order Motion-Compensated Spin Echo Diffusion Tensor Imaging of the Human Heart
    Stoeck, Christian T.
    von Deuster, Constantin
    Genet, Martin
    Atkinson, David
    Kozerke, Sebastian
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (04) : 1669 - 1676
  • [23] Validation of cardiac diffusion tensor imaging sequences: A multicentre test-retest phantom study
    Teh, Irvin
    Romero, William A. R.
    Boyle, Jordan
    Coll-Font, Jaume
    Dall'Armellina, Erica
    Ennis, Daniel B.
    Ferreira, Pedro F.
    Kalra, Prateek
    Kolipaka, Arunark
    Kozerke, Sebastian
    Lohr, David
    Mongeon, Francois-Pierre
    Moulin, Kevin
    Nguyen, Christopher
    Nielles-Vallespin, Sonia
    Raterman, Brian
    Schreiber, Laura M.
    Scott, Andrew D.
    Sosnovik, David E.
    Stoeck, Christian T.
    Tous, Cyril
    Tunnicliffe, Elizabeth M.
    Weng, Andreas M.
    Croisille, Pierre
    Viallon, Magalie
    Schneider, Jurgen E.
    NMR IN BIOMEDICINE, 2022, 35 (06)
  • [24] High resolution diffusion tensor imaging using interleaved echo-planar imaging
    Bammer, R
    Augustin, M
    Seifert, T
    Strasser-Fuchs, S
    Stollberger, R
    Wach, P
    Hartung, HP
    Fazekas, F
    MEDICAL IMAGING 2000: PHYSIOLOGY AND FUNCTION FORM MULTIDIMENSIONAL IMAGES, 2000, 3978 : 2 - 11
  • [25] Evaluation of interrater reliability of different muscle segmentation techniques in diffusion tensor imaging
    Forsting, Johannes
    Rehmann, Robert
    Rohm, Marlena
    Froeling, Martijn
    Schlaffke, Lara
    NMR IN BIOMEDICINE, 2021, 34 (02)
  • [26] Keyhole diffusion tensor imaging - a fast spin-echo based DTI technique
    Chu, W. C.
    Chen, Y. R.
    Chou, K. S.
    Chen Po-Chou
    Sun, S. W.
    2007 JOINT MEETING OF THE 6TH INTERNATIONAL SYMPOSIUM ON NONINVASIVE FUNCTIONAL SOURCE IMAGING OF THE BRAIN AND HEART AND THE INTERNATIONAL CONFERENCE ON FUNCTIONAL BIOMEDICAL IMAGING, 2007, : 43 - +
  • [27] Test-retest reliability and repeatability of renal diffusion tensor MRI in healthy subjects
    Cutajar, Marica
    Clayden, Jonathan D.
    Clark, Christopher A.
    Gordon, Isky
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (03) : E263 - E268
  • [28] Second order motion compensated spin-echo diffusion tensor imaging of the human heart
    Christian T Stoeck
    Constantin von Deuster
    Martin Genet
    David Atkinson
    Sebastian Kozerke
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [29] Diffusion-weighted radial fast spin-echo for high-resolution diffusion tensor imaging at 3T
    Sarlls, Joelle E.
    Pierpaoli, Carlo
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (02) : 270 - 276
  • [30] Improved gradient waveforms for oscillating gradient spin-echo (OGSE) diffusion tensor imaging
    Hennel, Franciszek
    Michael, Eric Seth
    Pruessmann, Klaas P.
    NMR IN BIOMEDICINE, 2021, 34 (02)