Stimulated echo acquisition mode (STEAM) diffusion tensor imaging with different diffusion encoding times in the supraspinatus muscle: Test-retest reliability and comparison to spin echo diffusion tensor imaging

被引:0
|
作者
Marth, Adrian Alexander [1 ,2 ]
Sommer, Stefan [1 ,3 ]
Feiweier, Thorsten [4 ]
Sutter, Reto [2 ,5 ]
Nanz, Daniel [1 ,5 ]
von Deuster, Constantin [1 ,3 ]
机构
[1] Balgrist Campus AG, Swiss Ctr Musculoskeletal Imaging SCMI, Zurich, Switzerland
[2] Balgrist Univ Hosp, Dept Radiol, Zurich, Switzerland
[3] Siemens Healthineers Int AG, Adv Clin Imaging Technol, Zurich, Switzerland
[4] Siemens Healthineers AG, Erlangen, Germany
[5] Univ Zurich UZH, Med Fac, Zurich, Switzerland
关键词
diffusion tensor imaging; muscle; stimulated Echo; EXERTIONAL COMPARTMENT SYNDROME; HUMAN SKELETAL-MUSCLE; 3.0; T; RELAXATION; CALF; REPEATABILITY; TRACKING; MRI; T-2; DTI;
D O I
10.1002/nbm.5279
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Diffusion tensor imaging (DTI) provides insight into the skeletal muscle microstructure and can be acquired using a stimulated echo acquisition mode (STEAM)-based approach to quantify time-dependent tissue diffusion. This study examined diffusion metrics and signal-to-noise ratio (SNR) in the supraspinatus muscle obtained with a STEAM-DTI sequence with different diffusion encoding times (Delta) and compared them to measures from a spin echo (SE) sequence. Ten healthy subjects (mean age 31.5 +/- 4.7 years; five females) underwent 3-Tesla STEAM and SE-DTI of the shoulder in three sessions. STEAM was acquired with Delta of 100/200/400/600 ms. The diffusion encoding time in SE scans was 19 ms (b = 500 s/mm(2)). Region of interest-based measurement of fractional anisotropy (FA), mean diffusivity (MD), and SNR was performed. Intraclass correlation coefficients (ICCs) were computed to assess test-retest reliability. ANOVA with post-hoc pairwise tests was used to compare measures between different Delta of STEAM as well as STEAM and SE, respectively. FA was significantly higher (FA(STEAM): 0.38-0.46 vs. FA(SE): 0.26) and MD significantly lower (MDSTEAM: 1.20-1.33 vs. MDSE: 1.62 x 10(-3) mm(2)/s) in STEAM compared to SE (p < 0.001, respectively). SNR was significantly higher for SE (72.3 +/- 8.7) than for STEAM (p < 0.001). ICCs were excellent for FA in STEAM (>= 0.911) and SE (0.960). For MD, ICCs were good for STEAM(100ms-600ms) (>= 0.759) and SE (0.752). STEAM and SE exhibited excellent reliability for FA and good reliability for MD in the supraspinatus muscle. SNR was significantly higher in SE compared to STEAM.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Normal values and test-retest variability of stimulated-echo diffusion tensor imaging and fat fraction measurements in the muscle
    Farrow, Matthew
    Grainger, Andrew J.
    Tan, Ai Lyn
    Buch, Maya H.
    Emery, Paul
    Ridgway, John P.
    Feiweier, Thorsten
    Tanner, Steven F.
    Biglands, John
    BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1101)
  • [2] Comparison of Twice Refocused Spin Echo Versus Stimulated Echo Diffusion Tensor Imaging for Tracking Muscle Fibers
    Noehren, Brian
    Andersen, Anders
    Feiweier, Thorsten
    Damon, Bruce
    Hardy, Peter
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (03) : 624 - 632
  • [3] Fast low-angle shot diffusion tensor imaging with stimulated echo encoding in the muscle of rabbit shank
    Hiepe, Patrick
    Herrmann, Karl-Heinz
    Guellmar, Daniel
    Ros, Christian
    Siebert, Tobias
    Blickhan, Reinhard
    Hahn, Klaus
    Reichenbach, Juergen R.
    NMR IN BIOMEDICINE, 2014, 27 (02) : 146 - 157
  • [4] Stimulated Echo Diffusion Tensor Imaging (STEAM-DTI) with Varying Diffusion Times as a Probe of Breast Tissue
    Teruel, Jose R.
    Cho, Gene Y.
    Moccaldi, Melanie
    Goa, Pal E.
    Bathen, Tone F.
    Feiweier, Thorsten
    Kim, Sungheon G.
    Moy, Linda
    Sigmund, Eric E.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (01) : 84 - 93
  • [5] Test-retest reliability of Diffusion Tensor Imaging metrics in neonates
    Merisaari, Harri
    Tuulari, Jetro J.
    Karlsson, Linnea
    Scheinin, Noora M.
    Parkkola, Riitta
    Saunavaara, Jani
    Lahdesmaki, Tuire
    Lehtola, Satu J.
    Keskinen, Maria
    Lewis, John D.
    Evans, Alan C.
    Karlsson, Hasse
    NEUROIMAGE, 2019, 197 : 598 - 607
  • [6] Test-retest reliability of diffusion tensor imaging of the liver at 3.0 T
    Girometti, Rossano
    Maieron, Marta
    Lissandrello, Giovanni
    Bazzocchi, Massimo
    Zuiani, Chiara
    RADIOLOGIA MEDICA, 2015, 120 (06): : 489 - 497
  • [7] Spin Echo Versus Stimulated Echo Diffusion Tensor Imaging of the In Vivo Human Heart
    von Deuster, Constantin
    Stoeck, Christian T.
    Genet, Martin
    Atkinson, David
    Kozerke, Sebastian
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (03) : 862 - 872
  • [8] Test-retest reliability of high spatial resolution diffusion tensor and diffusion kurtosis imaging
    Shahim, Pashtun
    Holleran, Laurena
    Kim, Joong H.
    Brody, David L.
    SCIENTIFIC REPORTS, 2017, 7
  • [9] Considerations in high-resolution skeletal muscle diffusion tensor imaging using single-shot echo planar imaging with stimulated-echo preparation and sensitivity encoding
    Karampinos, Dimitrios C.
    Banerjee, Suchandrima
    King, Kevin F.
    Link, Thomas M.
    Majumdar, Sharmila
    NMR IN BIOMEDICINE, 2012, 25 (05) : 766 - 778
  • [10] A tractography comparison between turboprop and spin-echo echo-planar diffusion tensor imaging
    Gui, Minzhi
    Peng, Huiling
    Carew, John D.
    Lesniak, Maciej S.
    Arfanakis, Konstantinos
    NEUROIMAGE, 2008, 42 (04) : 1451 - 1462