Simulation calculation and analysis of lightning induced overvoltage on power distribution lines

被引:9
|
作者
Yu, Zhanqing [1 ]
Zeng, Rong [1 ]
Wang, Shao'an [1 ]
Lu, Guojun [2 ]
Xiong, Jun [2 ]
Liu, Yu [2 ]
机构
[1] State Key Laboratory of Power Systems, Department of Electrical Engineering, Tsinghua University, Beijing 100084, China
[2] Guangzhou Power Supply Bureau, China Southern Power Grid Co. Ltd., Guangzhou 510400, China
来源
关键词
22;
D O I
10.3969/j.issn.1003-6520.2013.02.023
中图分类号
学科分类号
摘要
引用
收藏
页码:415 / 422
相关论文
共 50 条
  • [1] Calculation of lightning induced overvoltage on overhead distribution lines
    Beijing Key Laboratory of High Voltage and EMC , Changping District, Beijing 102206, China
    不详
    不详
    Zhongguo Dianji Gongcheng Xuebao, 2012, 31 (191-199):
  • [2] Calculation and experiment of induced lightning overvoltage on power distribution line
    Yu, Zhanqing
    Zhu, Tong
    Wang, Zezhong
    Lu, Guojun
    Zeng, Rong
    Liu, Yu
    Luo, Jianbin
    Wang, Yunchao
    He, Jinliang
    Zhuang, Chijie
    ELECTRIC POWER SYSTEMS RESEARCH, 2016, 139 : 52 - 59
  • [3] Calculation of Lightning-induced Voltages for Power Distribution Lines
    Fu, Jingwei
    An, Jianwei
    Liu, Gang
    Li, Te
    Xie, Shijun
    Deng, Jun
    Zhuang, Chijie
    He, Jinliang
    2018 34TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP 2018), 2018,
  • [4] Calculation model of lightning induced overvoltage using PSCAD/EMTDC program for overhead distribution lines
    College of Information and Control Engineering in China University of Petroleum, Qingdao
    266580, China
    Zhongguo Shiyou Daxue Xuebao (Ziran Kexue Ban), 4 (192-199):
  • [5] Overvoltage induced in overhead power lines by nearby lightning stroke
    Maslowski, Grzegorz
    Ziemba, Robert
    Kossowski, Tomasz
    PRZEGLAD ELEKTROTECHNICZNY, 2018, 94 (02): : 41 - 44
  • [6] Hazard of Induced Overvoltage to Power Distribution Lines
    Jiang Jun
    Zhao Rui
    Chen Jingyang
    Tian Hua
    Han Lin
    PROCEEDINGS OF THE 2016 4TH INTERNATIONAL CONFERENCE ON MACHINERY, MATERIALS AND COMPUTING TECHNOLOGY, 2016, 60 : 1334 - 1338
  • [7] Study on lightning overvoltage generated on power distribution lines with telecommunication cables
    Ishimoto, Kazuyuki
    Kawazoe, Takao
    Hidaka, Tetsuya
    Asakawa, Akira
    IEEJ Transactions on Power and Energy, 2013, 133 (12) : 967 - 973
  • [8] Calculation and analysis of lightning induced overvoltage with stratified ground structure
    Key Laboratory for Aerosol-Cloud-Precipitation of China Meteorological Administration, Collaborative Innovation Center on Forecast and Evaluation of Meteorological Disasters, Nanjing University of Information Science and Technology, Nanjing
    210044, China
    不详
    210019, China
    不详
    210044, China
    不详
    100089, China
    Gaodianya Jishu, 1 (84-93):
  • [9] Measurement of Lightning-Induced Overvoltage in Power Distribution Lines Using Ceramic-Capacitor Insulator
    Yang, Qing
    Yin, Lu
    Liu, Hongwen
    Wang, Ke
    Huang, Jisheng
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2019, 61 (03) : 788 - 795
  • [10] CALCULATION AND ANALYSIS OF LIGHTNING TRIP RATE BASED ON NUMERICAL CALCULATION OF INDUCED OVERVOLTAGE
    Xie, Rongbin
    Zhu, Jun
    Li, Jiangtao
    Wang, Yifeng
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES C-ELECTRICAL ENGINEERING AND COMPUTER SCIENCE, 2020, 82 (02): : 255 - 264