A finite element model of the human left ventricular systole

被引:32
作者
Institute for Biomedical Engineering, University and ETH Zurich, Gloriastrasse 35, CH-8092 Zurich, Switzerland [1 ]
不详 [2 ]
机构
[1] Institute for Biomedical Engineering, University and ETH Zurich, CH-8092 Zurich
[2] Experimental Thoracovascular and Cardiac Surgery, University of Munster, D-48149 Munster
来源
Comput. Methods Biomech. Biomed. Eng. | 2006年 / 5卷 / 319-341期
关键词
Contraction; Heart; Myocardium; Systole;
D O I
10.1080/10255840600960546
中图分类号
学科分类号
摘要
Local wall stress is the pivotal determinant of the heart muscle's systolic function. Under in vivo conditions, however, such stresses cannot be measured systematically and quantitatively. In contrast, imaging techniques based on magnetic resonance (MR) allow the determination of the deformation pattern of the left ventricle (LV) in vivo with high accuracy. The question arises to what extent deformation measurements are significant and might provide a possibility for future diagnostic purposes. The contractile forces cause deformation of LV myocardial tissue in terms of wall thickening, longitudinal shortening, twisting rotation and radial constriction. The myocardium is thereby understood to act as a densely interlaced mesh. Yet, whole cycle image sequences display a distribution of wall strains as function of space and time heralding a significant amount of inhomogeneity even under healthy conditions. We made similar observations previously by direct measurement of local contractile activity. The major reasons for these inhomogeneities derive from regional deviations of the ventricular walls from an ideal spheroidal shape along with marked disparities in focal fibre orientation. In response to a lack of diagnostic tools able to measure wall stress in clinical routine, this communication is aimed at an analysis and functional interpretation of the deformation pattern of an exemplary human heart at end-systole. To this end, the finite element (FE) method was used to simulate the three-dimensional deformations of the left ventricular myocardium due to contractile fibre forces at end-systole. The anisotropy associated with the fibre structure of the myocardial tissue was included in the form of a fibre orientation vector field which was reconstructed from the measured fibre trajectories in a post mortem human heart. Contraction was modelled by an additive second Piola-Kirchhoff active stress tensor. As a first conclusion, it became evident that longitudinal fibre forces, cross-fibre forces and shear along with systolic fibre rearrangement have to be taken into account for a useful modelling of systolic deformation. Second, a realistic geometry and fibre architecture lead to typical and substantially inhomogeneous deformation patterns as they are recorded in real hearts. We therefore, expect that the measurement of systolic deformation might provide useful diagnostic information. © 2006 Taylor & Francis Ltd.
引用
收藏
页码:319 / 341
页数:22
相关论文
共 65 条
[1]  
Arts T., Veenstra P.C., Reneman R.S., Epicardial deformation and left ventricular wall mechanics during ejection in the dog, Am. J. Physiol, 243, (1982)
[2]  
Bovendeerd P.H., Arts T., Huyghe J.M., van Campen D.H., Reneman R.S., Dependence of local left ventricular wall mechanics on myocardial fiber orientation: A model study, J. Biomech, 25, pp. 1129-1140, (1992)
[3]  
Bovendeerd P.H., Huyghe J.M., Arts T., van Campen D.H., Reneman R.S., Influence of endocardial-epicardial crossover of muscle fibers on left ventricular wall mechanics, J. Biomech, 27, pp. 941-951, (1994)
[4]  
Bovendeerd P.H., Arts T., Delhaas T., Huyghe J.M., van Campen D.H., Reneman R.S., Regional wall mechanics in the ischemic left ventricle: Numerical modeling and dog experiments, Am. J. Physiol, 270, (1996)
[5]  
Chadwick R.S., Mechanics of the left ventricle, Biophys. J, 39, pp. 279-288, (1982)
[6]  
Chadwick R.S., Ohayon J., Lewkowicz M., Wall-thickness and midwall-radius variations in ventricular mechanics, Proc. Natl. Acad. Sci. USA, 86, pp. 2996-2999, (1989)
[7]  
Chuong C.J., Fung Y.C., Frontiers in Biomechanics, pp. 117-129, (1986)
[8]  
Costa K.D., Takayama Y., McCulloch A.D., Covell J.W., Laminar fiber architecture and three-dimensional systolic mechanics in canine ventricular myocardium, Am. J. Physiol, 276, (1999)
[9]  
Cryer C.W., Navidi-Kasmai H., Lunkenheimer P.P., Redmann K., Computation of the alignment of myocardial contractile pathways using a magnetic tablet and an optical method, Technol. Health Care, 5, pp. 79-93, (1997)
[10]  
Dorri F., A finite element model of the human, (2004)