COP limit of an irreversible four-reservoir isothermal chemical pump

被引:0
|
作者
Xia, D. [1 ]
Chen, L. [1 ]
Sun, F. [1 ]
Wu, C. [2 ]
机构
[1] Postgraduate School, Naval University of Engineering, Wuhan 430033, China
[2] Mechanical Engineering Department, U. S. Naval Academy, Annapolis, MD 21402, United States
来源
International Journal of Ambient Energy | 2008年 / 29卷 / 04期
关键词
A new cyclic model of a four-reservoir isothermal chemical pump with irreversible mass transfer; mass leakage and internal dissipation is put forward in this paper. The maximum COP and the corresponding rate of energy pumping of the four-reservoir chemical pump are obtained. The influences of these irreversibilities and the ratios of chemical potentials of the reservoirs on the optimal performance of the chemical pump are revealed. © Ambient Press Limited 2008;
D O I
暂无
中图分类号
学科分类号
摘要
Journal article (JA)
引用
收藏
页码:181 / 188
相关论文
共 48 条
  • [11] Effects of mass transfer and mass leakage on performance of four-reservoir chemical pumps
    Xia, D.
    Chen, L. G.
    Sun, F. R.
    JOURNAL OF THE ENERGY INSTITUTE, 2009, 82 (03) : 176 - 179
  • [12] A fundamental optimal relationship of an endow reversible four-reservoir chemical potential transformer
    Xia, D.
    Chen, L.
    Sun, F.
    Wu, C.
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2009, 30 (01) : 33 - 44
  • [13] The maximum cop and the maximum cooling load of an irreversible four-heat-reservoir absorption refrigerator
    Chen, LG
    Zheng, T
    Sun, FR
    PROCEEDINGS OF THE 3RD INTERNATIONAL SYMPOSIUM ON HEAT TRANSFER ENHANCEMENT AND ENERGY CONSERVATION, VOLS 1 AND 2, 2004, : 516 - 522
  • [14] Performance optimization of diffusive mass transfer law irreversible isothermal chemical pump
    Chen, Lingen
    Shi, Shuangshuang
    Ge, Yanlin
    Feng, Huijun
    ENERGY, 2023, 263
  • [15] Theoretical Limit on COP of a Heat Pump from a Sequential System
    Park, Hansaem
    Kim, Min Soo
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2015, 23 (04)
  • [16] Optimal performance characteristics of an irreversible combined chemical pump
    Xia, ZR
    Lin, GX
    Hua, B
    Proceedings of ECOS 2005, Vols 1-3: SHAPING OUR FUTURE ENERGY SYSTEMS, 2005, : 601 - 608
  • [17] Heating load and COP optimizations for a class of generalized irreversible universal steady-flow variable-temperature heat reservoir heat pump cycle model
    Feng, Huijun
    Chen, Lingen
    Sun, Fengrui
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2010, 5 (04) : 210 - 222
  • [18] Performance optimization of an irreversible four-heat-reservoir absorption refrigerator
    Zheng, T
    Chen, LG
    Sun, FR
    Wu, C
    APPLIED ENERGY, 2003, 76 (04) : 391 - 414
  • [19] General performance characteristics of an irreversible three source chemical pump
    Lin, GX
    Chen, JC
    Hua, B
    ENERGY CONVERSION AND MANAGEMENT, 2003, 44 (10) : 1719 - 1731
  • [20] The optimal performance of an irreversible four-heat-reservoir absorption heat transformer
    Qin, Xiao-Yong
    Chen, Lin-Gen
    Sun, Feng-Rui
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2004, 25 (02): : 185 - 188