Myelin water imaging of in vivo and ex vivo human brains using multi-echo gradient echo at 3T and 7T

被引:0
|
作者
Xu, Guojun [1 ]
Zhao, Zhiyong [2 ]
Zhu, Qinfeng [1 ]
Zhu, Keqing [3 ,4 ,5 ,6 ]
Zhang, Jing [3 ,4 ,5 ,6 ]
Wu, Dan [1 ]
机构
[1] Zhejiang Univ, Dept Biomed Engn, Coll Biomed Engn & Instrument Sci, Key Lab Biomed Engn Minist Educ, Hangzhou, Peoples R China
[2] Zhejiang Univ, Childrens Hosp, Natl Clin Res Ctr Child Hlth, Sch Med, Hangzhou, Peoples R China
[3] Zhejiang Univ, China Brain Bank, Sch Med, Hangzhou, Peoples R China
[4] Zhejiang Univ, Dept Neurol, Affiliated Hosp 2,Sch Med, Key Lab Med Neurobiol Zhejiang Prov, Hangzhou, Peoples R China
[5] Zhejiang Univ, Dept Neurobiol, Sch Med, Hangzhou, Peoples R China
[6] Zhejiang Univ, First Affiliated Hosp & Sch Med, Dept Pathol, Hangzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
multi-echo gradient-echo; myelin water fraction; 3; T; 7; ex vivo; histological staining; MRI; RELAXATION; SCLEROSIS; FRACTION; POSTMORTEM; VISUALIZATION; COMPONENT; WHOLE; TIME;
D O I
10.1002/mrm.30310
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the myelin water fraction (MWF) measurements between 3 T and 7 T and between in vivo and ex vivo human brains, and to investigate the relationship between multi-echo gradient-echo (mGRE)-based 3D MWF and myelin content using histological staining, which has not been validated in the human brain. Methods: In this study, we performed 3D mGRE-based MWF measurements on five ex vivo human brain hemispheres and five healthy volunteers at 3 T and 7 T with 1mm isotropic resolution. The data were fitted with the T-2* based on a three compartment complex-valued model to estimate MWF. We obtained myelin basic protein (MBP) staining from two tissue blocks and co-registered the MWF map and histology image for voxel-wise correlation between the two. Results: The MWF values measured from 7 T were overall higher than 7 T, but data between the two field strength demonstrated high correlations both in vivo (r=0.88) and ex vivo (r=0.83) across 19 white matter regions. Moreover, the MWF measurements showed a good agreement between in vivo and ex vivo assessments at 3 T (r=0.61) and 7 T (r=0.54). Based on MBP staining, the MWF values exhibited strong positive correlations with myelin content on both 3 T (r=0.68 and r=0.78 for the two tissue blocks) and 7 T (r=0.64 and r=0.82 for the two tissue blocks). Conclusion: The findings demonstrated that the mGRE-based MWF mapping can be used to quantify myelin content in the human brain, despite the field-strength dependency of the measurements.
引用
收藏
页码:803 / 813
页数:11
相关论文
共 50 条
  • [31] Comparing the efficacy of data-driven denoising methods for a multi-echo fMRI acquisition at 7T
    Beckers, Abraham B.
    Drenthen, Gerhard S.
    Jansen, Jacobus F. A.
    Backes, Walter H.
    Poser, Benedikt A.
    Keszthelyi, Daniel
    NEUROIMAGE, 2023, 280
  • [32] High-resolution 31P echo-planar spectroscopic imaging in vivo at 7T
    Korzowski, Andreas
    Bachert, Peter
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (03) : 1251 - 1259
  • [33] Improved gradient echo magnitude- and phase-based mapping of T2 using multiple RF spoiling increments at 3T and 7T
    Wang, Difei
    Stirnberg, Ruediger
    Stoecker, Tony
    MAGNETIC RESONANCE IN MEDICINE, 2024, : 2328 - 2342
  • [34] T2*quantification using multi-echo gradient echo sequences: a comparative study of different readout gradients
    Shin, Seonyeong
    Yun, Seong Dae
    Shah, N. Jon
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [35] MR Spectroscopy of the Human Brain With Enhanced Singla Intensity at Ultrashort Echo Times on a Clinical Platform at 3T and 7T
    Mekle, Ralf
    Mlynarik, Vladimir
    Gambarota, Giulio
    Hergt, Martin
    Krueger, Gunnar
    Gruetter, Rolf
    MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (06) : 1279 - 1285
  • [36] In vivo perfusion measurements in the human placenta using echo planar imaging at 0.5 T
    Gowland, PA
    Francis, S
    Duncan, KR
    Freeman, AJ
    Issa, B
    Moore, RJ
    Bowtell, RW
    Baker, PN
    Johnson, IR
    Worthington, BS
    MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (03) : 467 - 473
  • [37] T2* quantification using multi-echo gradient echo sequences: a comparative study of different readout gradients
    Seonyeong Shin
    Seong Dae Yun
    N. Jon Shah
    Scientific Reports, 13
  • [38] Deuterium echo-planar spectroscopic imaging (EPSI) in the human liver in vivo at 7 T
    Nam, Kyung Min
    Gursan, Ayhan
    Bhogal, Alex A.
    Wijnen, Jannie P.
    Klomp, Dennis W. J.
    Prompers, Jeanine J.
    Hendriks, Arjan D.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (03) : 863 - 874
  • [39] Low SAR 31P (multi-echo) spectroscopic imaging using an integrated whole-body transmit coil at 7T
    van Houtum, Q.
    Welting, D.
    Gosselink, W. J. M.
    Klomp, D. W. J.
    Arteaga de Castro, C. S.
    van der Kemp, W. J. M.
    NMR IN BIOMEDICINE, 2019, 32 (12)
  • [40] Reproducibility and optimization of in vivo human diffusion-weighted MRS of the corpus callosum at 3T and 7T
    Wood, Emily T.
    Ercan, Ayse Ece
    Branzoli, Francesca
    Webb, Andrew
    Sati, Pascal
    Reich, Daniel S.
    Ronen, Itamar
    NMR IN BIOMEDICINE, 2015, 28 (08) : 976 - 987