Myelin water imaging of in vivo and ex vivo human brains using multi-echo gradient echo at 3T and 7T

被引:0
|
作者
Xu, Guojun [1 ]
Zhao, Zhiyong [2 ]
Zhu, Qinfeng [1 ]
Zhu, Keqing [3 ,4 ,5 ,6 ]
Zhang, Jing [3 ,4 ,5 ,6 ]
Wu, Dan [1 ]
机构
[1] Zhejiang Univ, Dept Biomed Engn, Coll Biomed Engn & Instrument Sci, Key Lab Biomed Engn Minist Educ, Hangzhou, Peoples R China
[2] Zhejiang Univ, Childrens Hosp, Natl Clin Res Ctr Child Hlth, Sch Med, Hangzhou, Peoples R China
[3] Zhejiang Univ, China Brain Bank, Sch Med, Hangzhou, Peoples R China
[4] Zhejiang Univ, Dept Neurol, Affiliated Hosp 2,Sch Med, Key Lab Med Neurobiol Zhejiang Prov, Hangzhou, Peoples R China
[5] Zhejiang Univ, Dept Neurobiol, Sch Med, Hangzhou, Peoples R China
[6] Zhejiang Univ, First Affiliated Hosp & Sch Med, Dept Pathol, Hangzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
multi-echo gradient-echo; myelin water fraction; 3; T; 7; ex vivo; histological staining; MRI; RELAXATION; SCLEROSIS; FRACTION; POSTMORTEM; VISUALIZATION; COMPONENT; WHOLE; TIME;
D O I
10.1002/mrm.30310
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the myelin water fraction (MWF) measurements between 3 T and 7 T and between in vivo and ex vivo human brains, and to investigate the relationship between multi-echo gradient-echo (mGRE)-based 3D MWF and myelin content using histological staining, which has not been validated in the human brain. Methods: In this study, we performed 3D mGRE-based MWF measurements on five ex vivo human brain hemispheres and five healthy volunteers at 3 T and 7 T with 1mm isotropic resolution. The data were fitted with the T-2* based on a three compartment complex-valued model to estimate MWF. We obtained myelin basic protein (MBP) staining from two tissue blocks and co-registered the MWF map and histology image for voxel-wise correlation between the two. Results: The MWF values measured from 7 T were overall higher than 7 T, but data between the two field strength demonstrated high correlations both in vivo (r=0.88) and ex vivo (r=0.83) across 19 white matter regions. Moreover, the MWF measurements showed a good agreement between in vivo and ex vivo assessments at 3 T (r=0.61) and 7 T (r=0.54). Based on MBP staining, the MWF values exhibited strong positive correlations with myelin content on both 3 T (r=0.68 and r=0.78 for the two tissue blocks) and 7 T (r=0.64 and r=0.82 for the two tissue blocks). Conclusion: The findings demonstrated that the mGRE-based MWF mapping can be used to quantify myelin content in the human brain, despite the field-strength dependency of the measurements.
引用
收藏
页码:803 / 813
页数:11
相关论文
共 50 条
  • [1] Myelin water imaging of in vivo and ex vivo human brains using multi-echo gradient echo at 3 T and 7 T
    Xu, Guojun
    Zhao, Zhiyong
    Zhu, Qinfeng
    Zhu, Keqing
    Zhang, Jing
    Wu, Dan
    MAGNETIC RESONANCE IN MEDICINE, 2024,
  • [2] Advances in gradient echo myelin water imaging at 3T and 7T
    Shin, Hyeong-Geol
    Oh, Se-Hong
    Fukunaga, Masaki
    Nam, Yoonho
    Lee, Doohee
    Jung, Woojin
    Jo, Minju
    Ji, Sooyeon
    Choi, Joon Yul
    Lee, Jongho
    NEUROIMAGE, 2019, 188 : 835 - 844
  • [3] Spin echo based cardiac diffusion imaging at 7T: An ex vivo study of the porcine heart at 7T and 3T
    Lohr, David
    Terekhov, Maxim
    Weng, Andreas Max
    Schroeder, Anja
    Walles, Heike
    Schreiber, Laura Maria
    PLOS ONE, 2019, 14 (03):
  • [4] Imaging arterial and venous vessels using Iron Dextran enhanced multi-echo 3D gradient echo MRI at 7T
    Li, Yinghao
    Li, Wei
    Paez, Adrian
    Cao, Di
    Sun, Yuanqi
    Gu, Chunming
    Zhang, Kaihua
    Miao, Xinyuan
    Liu, Peiying
    Li, Wenbo
    Pillai, Jay
    Lu, Hanzhang
    van Zijl, Peter C. M.
    Earley, Christopher
    Li, Xu
    Hua, Jun
    NMR IN BIOMEDICINE, 2024, 37 (12)
  • [5] Blind Source Separation for Myelin Water Fraction Mapping Using Multi-Echo Gradient Echo Imaging
    Song, Jae Eun
    Shin, Jaewook
    Lee, Hongpyo
    Lee, Ho Joon
    Moon, Won-Jin
    Kim, Dong-Hyun
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (06) : 2235 - 2245
  • [6] In-Vivo Myelin Water Imaging using T2*Decay at 7T
    Sati, Pascal
    Silva, Afonso C.
    Gaitan, Maria I.
    Wohler, Jillian E.
    Evangelou, Iordanis E.
    Massacesi, Luca
    Jacobson, Steven
    Reich, Daniel S.
    ANNALS OF NEUROLOGY, 2010, 68 (04) : S34 - S34
  • [7] Echo-time range effects on gradient-echo based myelin water fraction mapping at 3T
    Lee, Hongpyo
    Nam, Yoonho
    Kim, Dong-Hyun
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (04) : 2799 - 2807
  • [8] Histological Validation of Multi-Echo Gradient Echo (MGRE)-Derived Myelin Water Fraction (MWF) at 9.4 T and the Influence of Orientation on Quantification
    Thompson, Garth John
    Wang, Ziyi
    Kim, Jae-Yoon
    Li, Hui
    Kim, Dong-Hyun
    Ye, Qiong
    Su, Min-Ying
    NMR IN BIOMEDICINE, 2025, 38 (01)
  • [9] SENSITIVITY OF CEST MRI OF HUMAN KNEE CARTILAGE IN VIVO AT 3T AND 7T
    Haris, M.
    Singh, A.
    Kassey, V.
    Cai, K.
    Reddy, D.
    Hariharan, H.
    Reddy, R.
    OSTEOARTHRITIS AND CARTILAGE, 2011, 19 : S177 - S177
  • [10] Improved Multi-Echo Gradient-Echo-Based Myelin Water Fraction Mapping Using Dimensionality Reduction
    Song, Jae Eun
    Kim, Dong-Hyun
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2022, 41 (01) : 27 - 38