Development of A deep Learning-based algorithm for High-Pitch helical computed tomography imaging

被引:0
作者
Duan, Xiaoman [1 ]
Ding, Xiao Fan [1 ]
Khoz, Samira [2 ]
Chen, Xiongbiao [1 ,2 ]
Zhu, Ning [1 ,3 ,4 ]
机构
[1] Univ Saskatchewan, Coll Engn, Div Biomed Engn, Saskatoon, SK S7N 5A9, Canada
[2] Univ Saskatchewan, Coll Engn, Dept Mech Engn, Saskatoon, SK S7N 5A9, Canada
[3] Univ Saskatchewan, Coll Engn, Dept Chem & Biol Engn, Saskatoon, SK S7N 5A9, Canada
[4] Canadian Light Source, Saskatoon, SK S7N 2V3, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院; 加拿大创新基金会;
关键词
Deep learning; high-pitch helical CT; Propagation-based imaging; Biomedical imaging; LOW-DOSE CT;
D O I
10.1016/j.eswa.2024.125663
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
High-pitch X-ray helical computed tomography (HCT) imaging has been recently drawing considerable attention in biomedical fields due to its ability to reduce the scanning time and thus lower the radiation dose that objects (being imagined) may receive. However, the issue of compromised reconstruction quality caused by incomplete data in these high-pitch CT scans remains, thus limiting its applications. By addressing the aforementioned issue, this paper presents our study on the development of a novel deep leaning (DL)-based algorithm, ViT-U, for highpitch X-ray propagation-based imaging HCT (PBI-HCT) reconstruction. ViT-U consists of two key process modules of a vision transformer (ViT) and a convolutional neural network (i.e., U-Net), where ViT addresses the missing information in the data domain and U-Net enhances the post data-processing in the reconstruction domain. For verification, we designed and conducted simulations and experiments with both low-densitybiomaterial samples and biological-tissue samples to exemplify the biomedical applications, and then examined the ViT-U performance with varying pitches of 3, 3.5, 4, and 4.5, respectively, for comparison in term of radiation does and reconstruction quality. Our results showed that the high-pitch PBI-HCT allowed for the dose reduction from 72% to 93%. Importantly, our results demonstrated that the ViT-U exhibited outstanding performance by effectively removing the missing wedge artifacts thus enhancing the reconstruction quality of highpitch PBI-HCT imaging. Also, our results showed the superior capability of ViT-U to achieve high quality of reconstruction from the high-pitch images with the helical pitch value up to 4 (which allowed for the substantial reduction of radiation doses). Taken together, our DL-based ViT-U algorithm not only enables high-speed imaging with low radiation dose, but also maintains the high quality of imaging reconstruction, thereby offering significant potentials for biomedical imaging applications.
引用
收藏
页数:11
相关论文
共 42 条
  • [1] High-pitch, high temporal resolution, multi-energy cardiac imaging on a dual-source photon-counting-detector CT
    Ahmed, Zaki
    Campeau, David
    Gong, Hao
    Rajendran, Kishore
    Rajiah, Prabhakar
    McCollough, Cynthia
    Leng, Shuai
    [J]. MEDICAL PHYSICS, 2023, 50 (03) : 1428 - 1435
  • [2] RangeViT: Towards Vision Transformers for 3D Semantic Segmentation in Autonomous Driving
    Ando, Angelika
    Gidaris, Spyros
    Bursuc, Andrei
    Puy, Gilles
    Boulch, Alexandre
    Marlet, Renaud
    [J]. 2023 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, CVPR, 2023, : 5240 - 5250
  • [3] Lose The Views: Limited Angle CT Reconstruction via Implicit Sinogram Completion
    Anirudh, Rushil
    Kim, Hyojin
    Thiagarajan, Jayaraman J.
    Mohan, K. Aditya
    Champley, Kyle
    Bremer, Timo
    [J]. 2018 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2018, : 6343 - 6352
  • [4] Cao Hu, 2023, Computer Vision - ECCV 2022 Workshops: Proceedings. Lecture Notes in Computer Science (13803), P205, DOI 10.1007/978-3-031-25066-8_9
  • [5] CrossViT: Cross-Attention Multi-Scale Vision Transformer for Image Classification
    Chen, Chun-Fu
    Fan, Quanfu
    Panda, Rameswar
    [J]. 2021 IEEE/CVF INTERNATIONAL CONFERENCE ON COMPUTER VISION (ICCV 2021), 2021, : 347 - 356
  • [6] Biomaterials / bioinks and extrusion bioprinting
    Chen, X. B.
    Anvari-Yazdi, A. Fazel
    Duan, X.
    Zimmerling, A.
    Gharraei, R.
    Sharma, N. K.
    Sweilem, S.
    Ning, L.
    [J]. BIOACTIVE MATERIALS, 2023, 28 : 511 - 536
  • [7] A limited-angle CT reconstruction method based on anisotropic TV minimization
    Chen, Zhiqiang
    Jin, Xin
    Li, Liang
    Wang, Ge
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (07) : 2119 - 2141
  • [8] Dosovitskiy A., 2021, P INT C LEARN REPR I
  • [9] Duan XM, 2021, TISSUE ENG PART C-ME, V27, P573, DOI [10.1089/ten.tec.2021.0155, 10.1089/ten.TEC.2021.0155]
  • [10] Fan J, 2014, White paper