Design and implementation of grid-connected seamless transfer algorithm for distributed generation systems

被引:0
|
作者
Wang, Xiaohuan [1 ]
Zhang, Chunjiang [1 ]
机构
[1] Key Lab. of Power Electronics for Energy Conservation and Motor Drive of Hebei Province, Yanshan University, Qinhuangdao 066004, Hebei Province, China
来源
关键词
Electric power system control - Electric inverters - Electric power transmission networks - Electric power system interconnection;
D O I
暂无
中图分类号
学科分类号
摘要
The impulse current and voltage have impact the normal operating of Grid, inverter and load. To mitigate the impact on power grid and load during the mode-switching of grid-connected distributed generation (DG) system, this paper presents a voltage weighted control seamless transfer algorithm for a utility interactive three-phase inverter with grid-tied modes of operation. The paper analyzes the reasons of transient impact in detailed; there is an uncontrollable intermediate state in the transfer process of grid-connected, which will cause voltage and current overshoot. The effects of parameters weighted on transient are discussed. The algorithm can ensure that the transient transfer is seamless transfer without increasing system complexity. Simulation and experiment results verify the correctness and feasibility of the proposed method.
引用
收藏
页码:191 / 194
相关论文
共 50 条
  • [21] Simple synchronisation technique for three-phase grid-connected distributed generation systems
    Guo, Xiao-Qiang
    Wu, Wei-Yang
    IET RENEWABLE POWER GENERATION, 2013, 7 (01) : 55 - 62
  • [22] A proportion-feedback-integration control for the grid-connected inverter in distributed generation systems
    Guo, Xiao-Qiang
    Wu, Wei-Yang
    Gu, He-Rong
    Wang, Li-Qiao
    Zhao, Qing-Lin
    Kongzhi Lilun Yu Yingyong/Control Theory and Applications, 2009, 26 (08): : 923 - 926
  • [23] Active Damping of LCL Filter Resonance for Grid-Connected Distributed Power Generation Systems
    Zou, Benyu
    Bakhshai, Alireza
    Jain, Praveen
    45TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2019), 2019, : 4683 - 4688
  • [24] Impact of Grid-Connected Inverter Parameters on the Supraharmonic Emissions in Distributed Power Generation Systems
    Aboutaleb, Abdellatif M.
    Desmet, Jan
    Knockaert, Jos
    MACHINES, 2023, 11 (11)
  • [25] A control strategy of seamless transfer between grid-connected and islanding operation for microgrid
    Chen, Jie
    Chen, Xin
    Feng, Zhiyang
    Gong, Chunying
    Yan, Yangguang
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2014, 34 (19): : 3089 - 3097
  • [26] Synchronization Strategy of Microgrid from Islanded to Grid-connected Mode Seamless Transfer
    Xu, Haizhen
    Zhang, Xing
    Liu, Fang
    Zhu, Debin
    Shi, Rongliang
    Ni, Hua
    Cao, Wei
    2013 IEEE INTERNATIONAL CONFERENCE OF IEEE REGION 10 (TENCON), 2013,
  • [27] A Seamless and Autonomous Mode Transfer Method of Grid-connected Inverter with Critical Load
    Park, Sungyoul
    Choi, Sewan
    Kwon, Minho
    2019 10TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND ECCE ASIA (ICPE 2019 - ECCE ASIA), 2019,
  • [28] PR Based Indirect Current Control for Seamless Transfer of Grid-Connected Inverter
    Lim, Kyungbae
    Choi, Jaeho
    2016 IEEE 8TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (IPEMC-ECCE ASIA), 2016,
  • [29] Grid-connected distributed energy generation system planning and scheduling
    Ho, W. S.
    Chin, H. Y.
    Wong, K. C.
    Muis, Z. A.
    Hashim, H.
    DESALINATION AND WATER TREATMENT, 2014, 52 (4-6) : 1202 - 1213
  • [30] Research on Grid-connected and Economy of Distributed Wind Power Generation
    Liu Xinyuan
    Liu Pai
    Xu Hui
    Zheng Huiping
    Song Shuyong
    Hu Yezhou
    Yang Yong
    2014 17TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2014, : 1358 - 1361