7 Tesla MRI Liver Fat Quantification in Mice: Data Quality Assessment

被引:0
作者
Polei, Stefan [1 ]
Lindner, Tobias [2 ]
Abshagen, Kerstin [3 ]
Liebig, Marie [3 ]
Krause, Bernd J. [4 ]
Vollmar, Brigitte [3 ]
Weber, Marc-Andre [1 ]
机构
[1] Univ Med Ctr Rostock, Inst Diagnost & Intervent Radiol, Pediat Radiol & Neuroradiol, Rostock, Germany
[2] Rostock Univ, Core Facil Multimodal Small Anim Imaging, Med Ctr, Rostock, Germany
[3] Rostock Univ, Inst Expt Surg, Med Ctr, Rostock, Germany
[4] Rostock Univ, Med Ctr, Dept Nucl Med, Rostock, Germany
关键词
MRI; Small animal; Liver fat quantification; PDFF; Data quality; NAFLD; SATURATED FATS; FRACTION; ACCURACY; SEPARATION; DISEASE; VALIDATION; REPRODUCIBILITY; SPECTROSCOPY; CHILDREN; PHASE;
D O I
10.2174/0115734056263741231117112245
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The objective of this study was to evaluate the robustness of proton density fat fraction (PDFF) data determined by magnetic resonance imaging (MRI) and spectroscopy (MRS) via spatially resolved error estimation.Materials and Methods Using standard T2* relaxation time measurement protocols, in-vivo and ex-vivo MRI data with water and fat nominally in phase or out of phase relative to each other were acquired on a 7 T small animal scanner. Based on a total of 24 different echo times, PDFF maps were calculated in a magnitude-based approach. After identification of the decisive error-prone variables, pixel-wise error estimation was performed by simple propagation of uncertainty. The method was then used to evaluate PDFF data acquired for an explanted mouse liver and an in vivo mouse liver measurement.Results The determined error maps helped excluding measurement errors as cause of unexpected local PDFF variations in the explanted liver. For in vivo measurements, severe error maps gave rise to doubts in the acquired PDFF maps and triggered an in-depth analysis of possible causes, yielding abdominal movement or bladder filling as in vivo occurring reasons for the increased errors.Conclusion The combination of pixel-wise acquisition of PDFF data and the corresponding error maps allows for a more specific, spatially resolved evaluation of the PDFF value reliability.
引用
收藏
页数:10
相关论文
共 37 条
[1]   European Code against Cancer 4th Edition: Obesity, body fatness and cancer [J].
Anderson, Annie S. ;
Key, Timothy J. ;
Norat, Teresa ;
Scoccianti, Chiara ;
Cecchini, Michele ;
Berrino, Franco ;
Boutron-Ruault, Marie-Christine ;
Espina, Carolina ;
Leitzmann, Michael ;
Powers, Hilary ;
Wiseman, Martin ;
Romieu, Isabelle .
CANCER EPIDEMIOLOGY, 2015, 39 :S34-S45
[2]  
[Anonymous], 2014, Global Status Report on Noncommunicable Diseases 2014
[3]   Quantitative magnetic resonance imaging of hepatic steatosis: Validation in ex vivo human livers [J].
Bannas, Peter ;
Kramer, Harald ;
Hernando, Diego ;
Agni, Rashmi ;
Cunningham, Ashley M. ;
Mandal, Rakesh ;
Motosugi, Utaroh ;
Sharma, Samir D. ;
del Rio, Alejandro Munoz ;
Fernandez, Luis ;
Reeder, Scott B. .
HEPATOLOGY, 2015, 62 (05) :1444-1455
[4]   A murine model for non-alcoholic steatohepatitis showing evidence of association between diabetes and hepatocellular carcinoma [J].
Fujii, Masato ;
Shibazaki, Yuichiro ;
Wakamatsu, Kyoko ;
Honda, Yutaka ;
Kawauchi, Yusuke ;
Suzuki, Kenji ;
Arumugam, Somasundaram ;
Watanabe, Kenichi ;
Ichida, Takafumi ;
Asakura, Hitoshi ;
Yoneyama, Hiroyuki .
MEDICAL MOLECULAR MORPHOLOGY, 2013, 46 (03) :141-152
[5]   Accuracy of PDFF Estimation by Magnitude-Based and Complex-Based MRI in Children with MR Spectroscopy as a Reference [J].
Haufe, William M. ;
Wolfson, Tanya ;
Hooker, Catherine A. ;
Hooker, Jonathan C. ;
Covarrubias, Yesenia ;
Schlein, Alex N. ;
Hamilton, Gavin ;
Middleton, Michael S. ;
Angeles, Jorge E. ;
Hernando, Diego ;
Reeder, Scott B. ;
Schwimmer, Jeffrey B. ;
Sirlin, Claude B. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (06) :1641-1647
[6]   Addressing phase errors in fat-water imaging using a mixed magnitude/complex fitting method [J].
Hernando, D. ;
Hines, C. D. G. ;
Yu, H. ;
Reeder, S. B. .
MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (03) :638-644
[7]   Multisite, Multivendor Validation of the Accuracy and Reproducibility of Proton-Density Fat-Fraction Quantification at 1.5T and 3T Using a Fat-Water Phantom [J].
Hernando, Diego ;
Sharma, Samir ;
Ghasabeh, Mounes Aliyari ;
Alvis, Bret ;
Arora, Sandeep ;
Hamilton, Gavin ;
Pan, Li ;
Shaffer, Jean ;
Sofue, Keitaro ;
Szeverenyi, Nikolaus ;
Welch, E. Brian ;
Yuan, Qing ;
Bashir, Mustafa ;
Kamel, Ihab ;
Rice, Mark ;
Sirlin, Claude ;
Yokoo, Takeshi ;
Reeder, Scott .
MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (04) :1516-1524
[8]   T1 Independent, T2* Corrected MRI With Accurate Spectral Modeling for Quantification of Fat: Validation in a Fat-Water-SPIO Phantom [J].
Hines, Catherine D. G. ;
Yu, Huanzhou ;
Shimakawa, Ann ;
McKenzie, Charles A. ;
Brittain, Jean H. ;
Reeder, Scott B. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (05) :1215-1222
[9]  
Hu FB, 1999, AM J CLIN NUTR, V70, P1001
[10]   The Pathology of Atherosclerosis: Plaque Development and Plaque Responses to Medical Treatment [J].
Insull, William, Jr. .
AMERICAN JOURNAL OF MEDICINE, 2009, 122 (01) :S3-S14