Quantification of gimeracil, tegafur, and 5-FU in human plasma via LC-MS/ MS with a simplified pretreatment using flow-through extraction

被引:0
作者
Ando, Motozumi [1 ]
Watanabe, Norio [1 ]
Seike, Riko [1 ]
Gocho, Saori [2 ]
Maeda, Shoko [2 ]
Inagaki, Masami [2 ]
Kawahara, Masami [1 ]
机构
[1] Aichi Gakuin Univ, Sch Pharm, Lab Clin Pharm & Sci, 1-100 Kusumoto cho,Chikusa ku, Nagoya, Aichi 4648650, Japan
[2] Nagoya Ekisaikai Hosp, Dept Pharm, 4-66 Shonen Cho,Nakagawa Ku, Nagoya 4548502, Japan
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2025年 / 1251卷
关键词
Gimeracil; Tegafur; 5-fluorouracil; Therapeutic drug monitoring; Human plasma; Tandem mass spectrometry; 5-FLUOROURACIL; QUANTITATION; TOXICITY; URACIL; S-1;
D O I
10.1016/j.jchromb.2024.124424
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Gimeracil, a component in S-1 (an oral anticancer agent comprising tegafur, a prodrug of 5-fluorouracil (5-FU), potassium oxonate, and gimeracil), inhibits metabolic enzymes, thereby impeding 5-FU degradation. Therefore, the blood level of gimeracil is closely associated with the disposition of 5-FU, and quantification of gimeracil can provide important information if a case shows an inappropriate 5-FU blood concentration. Nevertheless, methods for quantifying gimeracil in human plasma are rarely reported. Herein, we aimed to develop a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantifying gimeracil, in addition to tegafur and 5-FU, levels in human plasma using a clinically applicable simplified pretreatment process and faster elution time. Hence, an acetamide-functionalized monolith silica disk-packed spin column was used to extract gimeracil and internal standard (IS; nicotinamide), whereas diatomaceous earth-based solid phase for liquid-liquid extraction was used to extract tegafur, 5-FU, and IS (5-chlorouracil) from plasma. Each extract was analyzed within 4 min of elution via LC-MS/MS using a shared LC column and mobile phase. Accuracy and precision analyses indicated lower limits of quantification of 5, 10, and 2 ng/mL for gimeracil, tegafur, and 5-FU, respectively. The calibration curves showed good linearity between 5 and 500 ng/mL for gimeracil, 10 and 5000 ng/mL for tegafur, and 2 and 1000 ng/mL for 5-FU. We confirmed that the levels of all analytes in the plasma of patients with cancer undergoing S-1-inclusive therapy were within the calibration range for each analyte. Thus, this newly developed quantification method is likely to be useful for optimization of S-1 therapy.
引用
收藏
页数:5
相关论文
共 16 条
[1]  
[Anonymous], 2013, Guideline on Bioanalytical Method Validation in Pharmaceutical Development, P1
[2]   LC-MS/MS method for simultaneous analysis of uracil, 5,6-dihydrouracil, 5-fluorouracil and 5-fluoro-5,6-dihydrouracil in human plasma for therapeutic drug monitoring and toxicity prediction in cancer patients [J].
Buechel, Barbara ;
Rhyn, Peter ;
Schuerch, Stefan ;
Buehr, Claudia ;
Amstutz, Ursula ;
Largiader, Carlo R. .
BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (01) :7-16
[3]  
Deac Andrada-Larisa, 2023, Med Pharm Rep, V96, P413, DOI 10.15386/mpr-2643
[4]   Simultaneous Determination of Tegafur and Gimeracil in Human Plasma by Liquid Chromatography/Tandem Mass Spectrometry [J].
Gu, Yuan ;
Lu, Rong ;
Si, Duanyun ;
Liu, Changxiao .
ANALYTICAL SCIENCES, 2009, 25 (10) :1211-1215
[5]   LC-MS/MS assay for the quantitation of FdCyd and its metabolites FdUrd and FU in human plasma [J].
Holleran, Julianne L. ;
Eiseman, Julie L. ;
Parise, Robert A. ;
Kummar, Shivaani ;
Beumer, Jan H. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 129 :359-366
[6]   Severe adverse effects of 5-fluorouracil in S-1 were lessened by haemodialysis due to elimination of the drug [J].
Inoue, Kazunori ;
Nagasawa, Yasuyuki ;
Yamamoto, Ryohei ;
Omori, Hiroki ;
Kimura, Tomonori ;
Tomida, Kodo ;
Furumatsu, Yoshiyuki ;
Imai, Enyu ;
Isaka, Yoshitaka ;
Rakugi, Hiromi .
CLINICAL KIDNEY JOURNAL, 2009, 2 (02) :152-154
[7]   A simultaneous determination method for 5-fluorouracil and its metabolites in human plasma with linear range adjusted by in-source collision-induced dissociation using hydrophilic interaction liquid chromatography-electrospray ionization-tandem mass spectrometry [J].
Ishii, Hideaki ;
Shimada, Miki ;
Yamaguchi, Hiroaki ;
Mano, Nariyasu .
BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (11) :1882-1886
[8]   Quantitation of 5-fluorouracil (5-FU) in human plasma by liquid chromatography/electrospray ionization tandem mass spectrometry [J].
Kosovec, Juliann E. ;
Egorin, Merrill J. ;
Gjurich, Susanna ;
Beumer, Jan H. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (02) :224-230
[9]   Determination of tegafur, 5-fluorouracil, gimeracil and oxonic acid in human plasma using liquid chromatography-tandem mass spectrometry [J].
Liu, Ke ;
Zhong, Dafang ;
Zou, Huiyu ;
Chen, Xiaoyan .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 52 (04) :550-556
[10]   Development and utilization of a combined LC-UV and LC-MS/MS method for the simultaneous analysis of tegafur and 5-fluorouracil in human plasma to support a phase I clinical study of oral UFT®/leucovorin [J].
Peer, Cody J. ;
McManus, Terence J. ;
Hurwitz, Herbert I. ;
Petros, William P. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 898 :32-37