Indoor environmental quality and subjective perceptions in multi-chair dental offices

被引:2
作者
Zong, Jie [1 ,2 ]
Ai, Zhengtao [1 ,2 ]
Melikov, Arsen Krikor [3 ]
Cao, Shicheng [1 ,2 ]
机构
[1] Hunan Univ, Coll Civil Engn, Dept Bldg Environm & Energy, Changsha, Hunan, Peoples R China
[2] Hunan Univ, Natl Ctr Int Res Collaborat Bldg Safety & Environm, Changsha, Hunan, Peoples R China
[3] Tech Univ Denmark, Int Ctr Indoor Environm & Energy, Dept Environm & Resource Engn, DK-2800 Lyngby, Denmark
关键词
Indoor environmental quality; Field measurement; Questionnaire survey; Dental treatment; Multi-chair dental office; HEALTH-CARE FACILITIES; NOISE-LEVELS; THERMAL COMFORT; SATISFACTION; BUILDINGS; ANNOYANCE; CLINICS; IEQ;
D O I
10.1016/j.buildenv.2024.112196
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indoor environmental quality (IEQ) in multi-chair dental offices is strongly related to treatment effectiveness, patient comfort, and dental professionals' occupational exposure. This study conducts comprehensive field measurements and questionnaire surveys to assess the IEQ in two multi-chair dental offices of the Periodontal Department (PD) and the Endodontics Department (ED) in a stomatological hospital in Changsha during the transitional season, summer, and winter. It first reveals the IEQ status and then examines its impact on the perceptions of both dental professionals and patients. The results indicate no considerable difference in IEQ between the PD and the ED. For the measurement, the worst IEQ is observed in winter, with air temperature, relative humidity, PM2.5 concentration, and sound pressure level not meeting the prescribed limits. The worst case is for the PM2.5 concentration, where the highest daily average level is 1.6-4.0 times higher than the limit. However, according to the questionnaire surveys, the highest participant satisfaction score of the overall environment is also observed in winter (i.e., 1.0). The inconsistent results reflected from the measurements and surveys demonstrate the complex influence of a multi-parameter environment on subjective perceptions. Additionally, dental professionals as long-term occupants of the dental offices, report a lower level of overall environmental satisfaction (i.e., 0.38) compared to patients (i.e., 0.86), especially regarding air quality and acoustic environment. These findings are important information for improving environmental standards and formulating accurate environmental control methods, which then contribute to enhanced health, well-being, and performance of both dental professionals and patients.
引用
收藏
页数:18
相关论文
共 60 条
  • [1] CFD study of the air distribution and occupant draught sensation in a patient ward equipped with protected zone ventilation
    Aganovic, Amar
    Steffensen, Marie
    Cao, Guangyu
    [J]. BUILDING AND ENVIRONMENT, 2019, 162
  • [2] Noise levels, noise annoyance, and hearing-related problems in a dental college
    Ahmed, Hafiz Omer
    Ali, Wesal Jasim
    [J]. ARCHIVES OF ENVIRONMENTAL & OCCUPATIONAL HEALTH, 2017, 72 (03) : 159 - 165
  • [3] Noise level and its influences on dental professionals in a dental hospital in Hong Kong
    Ai, Z. T.
    Mak, C. M.
    Wong, H. M.
    [J]. BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2017, 38 (05) : 522 - 535
  • [4] Factors affecting performance of hospital nurses in Riyadh Region, Saudi Arabia
    Al-Ahmadi, Hanan
    [J]. INTERNATIONAL JOURNAL OF HEALTH CARE QUALITY ASSURANCE, 2009, 22 (01) : 40 - +
  • [5] Evaluating aerosol and splatter following dental procedures: Addressing new challenges for oral health care and rehabilitation
    Allison, James R.
    Currie, Charlotte C.
    Edwards, David C.
    Bowes, Charlotte
    Coulter, Jamie
    Pickering, Kimberley
    Kozhevnikova, Ekaterina
    Durham, Justin
    Nile, Christopher J.
    Jakubovics, Nicholas
    Rostami, Nadia
    Holliday, Richard
    [J]. JOURNAL OF ORAL REHABILITATION, 2021, 48 (01) : 61 - 72
  • [6] [Anonymous], 1998, ISO 7726 ERGONOMICS
  • [7] [Anonymous], 2022, Standards for Indoor Air Quality
  • [8] [Anonymous], 2013, GB 50034-2013
  • [9] Evaluation of Noise Levels in a University Dental Clinic
    Antoniadou, Maria
    Tziovara, Panagiota
    Konstantopoulou, Sophia
    [J]. APPLIED SCIENCES-BASEL, 2023, 13 (19):
  • [10] HVAC and indoor thermal conditions in hospital operating rooms
    Balaras, Constantinos A.
    Dascalaki, Elena
    Gaglia, Athina
    [J]. ENERGY AND BUILDINGS, 2007, 39 (04) : 454 - 470