Safety distances for hydrogen filling stations

被引:0
|
作者
RIVM Centre for External Safety, Bilthoven, Netherlands [1 ]
机构
[1] RIVM Centre for External Safety, Bilthoven
来源
Fuel Cells Bull. | 2006年 / 11卷 / 12-16期
关键词
D O I
10.1016/S1464-2859(06)71247-0
中图分类号
学科分类号
摘要
In the context of spatial planning, the Dutch Ministry of Housing, Spatial Planning and the Environment asked the Centre for External Safety of the National Institute for Public Health and the Environment (RIVM) to advise on safe distances pertaining to hydrogen filling stations. The RIVM made use of failure modeling and parameters for calculating the distance in detail. An imaginary hydrogen filling station for cars is used in the determination of 'external safety' or third-party distances for the installations and the pipework for three different sizes of hydrogen filling stations. For several failure scenarios 'effect' distances are calculated for car filling at 350 and 700 bar (5000 and 10 000 psi). Safe distances of filling stations from locations where people live and work appear to be similar for compressed hydrogen, gasoline (petrol) and compressed natural gas. Safe distances for LPG are greater. A filling unit for hydrogen can be placed at gasoline filling stations without increasing safety distances. © 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:12 / 16
页数:4
相关论文
共 50 条
  • [21] Technical developments and kobe steel's business approach for hydrogen filling stations
    Miura, Shinichi
    Manabe, Yasuo
    Nagura, Kenji
    Noishiki, Koji
    Kurishiro, Yuji
    R and D: Research and Development Kobe Steel Engineering Reports, 2014, 64 (01): : 49 - 53
  • [22] Improved handling of liquid hydrogen at filling stations: Review of six years' experience
    Wetzel, FJ
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 1998, 23 (05) : 339 - 348
  • [23] Analysis of Hydrogen Value Chain Events: Implications for Hydrogen Refueling Stations' Safety
    Badia, Eulalia
    Navajas, Joaquin
    Sala, Roser
    Paltrinieri, Nicola
    Sato, Hitomi
    SAFETY, 2024, 10 (02)
  • [24] Enhancing safety in hydrogen refuelling stations: Computational analysis of hydrogen explosion hazards
    Patel, Parth
    Garaniya, Vikram
    Baalisampang, Til
    Arzaghi, Ehsan
    Abbassi, Rouzbeh
    Salehi, Fatemeh
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2025, 103 (01) : 82 - 97
  • [25] Safety aspects of future infrastructure scenarios with hydrogen refuelling stations
    Markert, F.
    Nielsen, S. K.
    Paulsen, J. L.
    Andersen, V.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2007, 32 (13) : 2227 - 2234
  • [26] MATERIAL SELECTION AND SAFETY VALIDATION OF STEEL TANKS FOR HYDROGEN STATIONS
    Wada, Yoru
    ASME PRESSURE VESSELS AND PIPING CONFERENCE - 2014, VOL 6B, 2014,
  • [27] RISK OF EXPLOSION AT FILLING STATIONS
    不详
    ERDOL & KOHLE ERDGAS PETROCHEMIE, 1993, 46 (12): : 441 - 441
  • [28] Safety Distance Determination Methods for Hydrogen Refueling Stations: A Review
    Zhang, Jiaxin
    Kong, Xiangling
    Ba, Qingxin
    Wang, Ping
    Li, Xuefang
    SAE International journal of Sustainable Transportation, Energy, Environment, and Policy, 2022, 4 (01):
  • [29] AUTOMATION OF FILLING STATIONS.
    Filippini, Umberto
    Quaderni Pignone, 1977, (23): : 38 - 42
  • [30] Smart switching and protection technology for hydrogen filling stations: Key technology for successful mobility
    Hummel, Ralf