Experimental study on seismic behavior of steel frame-concrete lateral force resisting wall fabricated structures

被引:0
|
作者
Zhou, Tianhua [1 ]
Wu, Hanheng [1 ]
Chen, Junwu [1 ]
Bai, Liang [1 ]
机构
[1] School of Civil Engineering, Chang'an University, Xi'an
来源
Jianzhu Jiegou Xuebao/Journal of Building Structures | 2015年 / 36卷 / 06期
关键词
Concrete lateral resistance wall; Fabricated structure; Quasi-static test; Seismic performance; Steel frame;
D O I
10.14006/j.jzjgxb.2015.06.004
中图分类号
学科分类号
摘要
In order to research the seismic behavior of steel frame-concrete lateral force resisting wall fabricated structures, two full scale specimens composed of steel frame and reinforced concrete lateral force resisting wall were tested under cyclic horizontal loading, and the failure mode, hysteretic behavior, ductility and deformation and energy dissipation were investigated. Experimental results show that the structure is a typical double lateral force resisting system. As the first line of defense for the structural system, the concrete lateral force resisting wall shares the main lateral load at the early loading stage, and steel frame is the second line of defense for the structural system after the concrete lateral force resisting wall is out of work, and at the later loading stage, steel frame shares all of the lateral load and overall overturning moment because of the connection damage of concrete lateral force resisting wall at its top position. ©, 2015, Science Press. All right reserved.
引用
收藏
页码:29 / 34
页数:5
相关论文
共 9 条
  • [1] Fang Y., Gu Q., Shen L., Hysteretic behavior of simi-rigid composite steel frame with reinforced concrete infill wall in column weak axis, Journal of Building Structures, 29, 2, pp. 51-62, (2008)
  • [2] Peng X., Gu Q., Lin C., Experimental study on steel frame-reinforced concrete infill wall structures with semi-rigid joints, China Civil Engineering Journal, 41, 1, pp. 64-69, (2008)
  • [3] Sun G., Gu Q., Fang Y., Shen L., Experimental study of partially-restrained steel frame with RC infill walls global performance analysis, China Civil Engineering Journal, 43, 1, pp. 35-46, (2010)
  • [4] Sun G., Gu Q., He R., Shen L., Fang Y., Experimental investigation of partially-restrained steel frame with concealed vertical slits RC infill walls, Journal of Building Structures, 31, 9, pp. 16-26, (2010)
  • [5] Zhao W., Tong G., Yang Q., Experimental study on seismic behavior of steel frame with prefabricated reinforced concrete infill slit shear walls, Journal of Building Structures, 33, 7, pp. 141-146, (2012)
  • [6] Zhao W., Tong G., Zhou G., Wu C., Experimental investigation of steel frame with infill prefabricated reinforce-concrete shear walls, Journal of Civil, Architectural & Environmental Engineering, 35, 1, pp. 63-69, (2013)
  • [7] Zhou T., Wu H., Bai L., Jiang L., Chen J., Fabricated structural system of steel frame-prefabricated concrete lateral resistance wall, Journal of Architecture and Civil Engineering, 30, 3, pp. 1-6, (2013)
  • [8] Zhou T., Wu H., Bai L., Guan Y., Li W., Wang S., Experimental study on seismic behavior of steel frame-steel reinforced concrete lateral force resisting wall fabricated structures, Journal of Building Structures, 35, 7, pp. 131-137, (2014)
  • [9] Zhou T., Guan Y., Wu H., Bai L., Research on vertical mechanical behavior of steel frame-prefabricated concrete lateral resistance wall fabricated structures, Journal of Building Structures, 35, 9, pp. 27-34, (2014)