Calibration method for spatially resolved tomographic spectroscopy based on a time-domain interferometer

被引:0
作者
Sakatsume, Masaya [1 ]
Thai, Bao Dinh [2 ]
Shioda, Tatsutoshi [2 ]
机构
[1] Nagaoka Univ Technol, Dept Elect Engn, 1603-1 Kamitomioka, Nagaoka, Niigata 9402188, Japan
[2] Saitama Univ, Grad Sch Sci & Engn, 255 Shimo Okubo, Saitama, Saitama 3388570, Japan
关键词
Spatially resolved spectroscopy (SRS); Time-domain interferometer; Tomography; Spectral calibration; SINGLE-SHOT TOMOGRAPHY;
D O I
10.1016/j.optcom.2024.131180
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Low-coherence time-domain based spatially resolved tomographic spectroscopy was developed to simultaneously achieve complex electric field and the tomography of the transparent multilayer samples. More importantly, we constructed a novel calibration method that overcomes the shortcomings of the cross-correlation output of traditional spatially resolved spectroscopy using the Wiener-Khinchin theorem. With the proposed method, we obtained a more accurate complex electric field spectrum for each sample interface, which is fundamental for precisely determining various physical parameters, including power reflectance, refractive index, and geometric length, as long as the turbidity of sample was sufficient for the light signal travel and return to the detector. The proposed theory was experimentally validated with both a single interface mirror (single layer) and double interfaces micrometer-thickness cover glass (three-layers) sample, which was measured by an infrared light source (1.4 mu m-1.7 mu m). We successfully resolved the precise refractive index of the second layer (1.45) obtained from the power reflectivities of the sample interfaces (3.36% and 3.55%) and obtained the sample depth of 52 mu m. The tomography was detected by a high-speed photodetector and recorded by a digital multi-meter (50,000 samples per second). The validity of the spectral calibration was confirmed by comparing the measured spectra with theoretical spectra obtained via numerical simulations.
引用
收藏
页数:9
相关论文
共 25 条
[1]  
Becker E.D., 1972, Sci., V178, P178
[2]   Live volumetric (4D) visualization and guidance of in vivo human ophthalmic surgery with intraoperative optical coherence tomography [J].
Carrasco-Zevallos, O. M. ;
Keller, B. ;
Viehland, C. ;
Shen, L. ;
Waterman, G. ;
Todorich, B. ;
Shieh, C. ;
Hahn, P. ;
Farsiu, S. ;
Kuo, A. N. ;
Toth, C. A. ;
Izatt, J. A. .
SCIENTIFIC REPORTS, 2016, 6
[3]  
Cho RK, 1998, JOURNAL OF NEAR INFRARED SPECTROSCOPY, VOL 6 1998, pA75
[4]   HIGH-SPEED NONCONTACT PROFILER BASED ON SCANNING WHITE-LIGHT INTERFEROMETRY [J].
DECK, L ;
DEGROOT, P .
APPLIED OPTICS, 1994, 33 (31) :7334-7338
[5]   Computational-imaging-based optical coherence tomography in time- and frequency-domain [J].
Du, Mengqi ;
Eikema, Kjeld S. E. ;
Witte, Stefan .
OSA CONTINUUM, 2019, 2 (11) :3141-3152
[6]   WHITE-LIGHT INTERFEROMETRIC THICKNESS GAUGE [J].
FLOURNOY, PA ;
WYNTJES, G ;
MCCLURE, RW .
APPLIED OPTICS, 1972, 11 (09) :1907-&
[7]   Linear propagation of light investigated with a white-light Michelson interferometer [J].
Fuji, T ;
Miyata, M ;
Kawato, S ;
Hattori, T ;
Nakatsuka, H .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1997, 14 (05) :1074-1078
[8]   Spatially resolved determination of the electronic density and temperature by a visible spectro-tomography diagnostic in a linear magnetized plasma [J].
Gonzalez-Fernandez, V. ;
David, P. ;
Baude, R. ;
Escarguel, A. ;
Camenen, Y. .
SCIENTIFIC REPORTS, 2020, 10 (01)
[9]   A FOURIER TRANSFORM SPECTROMETER FOR 10-10000 CM-1 SPECTRAL REGION [J].
HOCHHEIMER, BF ;
BRADLEY, CF .
APPLIED OPTICS, 1969, 8 (03) :557-+
[10]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181