Non-contact rotation angle measurement system for scanning mirrors

被引:0
作者
Wang, Yang [1 ,2 ]
Yan, Chang-Xiang [1 ]
Hu, Chun-Hui [1 ]
Wang, Yi-Qun [1 ]
Gu, Zhi-Yuan [1 ,2 ]
Zhang, Da [1 ]
Zhang, Xin-Jie [1 ]
机构
[1] Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences
[2] University of Chinese Academy of Sciences
来源
Guangxue Jingmi Gongcheng/Optics and Precision Engineering | 2014年 / 22卷 / 04期
关键词
Angle measurement; Error analysis; Non-contact measurement; Polynomial fitting; Scanning mirror; Spectroscopic imager;
D O I
10.3788/OPE.20142204.0850
中图分类号
学科分类号
摘要
A non-contact rotation angle measurement system based on a line laser, and a linear array CCD was established to extent the angle measuring scope of a scanning mirror. The structure and measurement principle of the measurement system were introduced. It calculates the rotational angle of the scanning mirror by the position of the laser spot on the linear CCD and extents the measuring scope by array mirrors with special design. To reduce the alignment requirements, the error was analyzed and a calibration measurement method with polynomial fitting was verified. A series of error sources that affect the measurement accuracy were analyzed and the total errors of the measurement system were calculated. Finally, the related measurement experiment was performed. Experimental results indicate that the measurement system can offer a resolution of 2.5″, angular measurement range of 11 °, and the precision of angular measurement is up to 3″. Obtained results can satisfy the system requirements for non-contact, higher precision and wider measurement ranges.
引用
收藏
页码:850 / 855
页数:5
相关论文
共 11 条
[1]  
Yuan L., Gao W.J., Research on design and manufacture of space remote sensor's big lighten scan mirror, Advanced Optical Manufacture and Testing Technology, Proceeding of SPIE, (2000)
[2]  
Chen W., Ding Y.L., Hui S.W., Design of kinematic mount for SiC scanning mirror, Chinese Optics, 5, 2, pp. 161-166, (2012)
[3]  
Huang P.S., Kiyono S., Kamada O., Angle measurement based on the internal-reflection effect: a new method, Appl. Opt., 31, pp. 6047-6055, (1992)
[4]  
Masroor I., Ghazanfar H., Michelson interferometer for precision angle measurement, Appl. Opt., 1, pp. 113-120, (1999)
[5]  
Jiang Z.M., Wu J.X., Zhuang Z.T., Angle Measurement, (1995)
[6]  
Filatov Y.V., Loukianov D.P., Probse R., Dynamic angle measurement by means of a ring laser, Metrologia, 34, pp. 343-351, (1997)
[7]  
Krishna R., Improved pointing accuracy using high precision theodolite measurements, SPIE, 2812, pp. 199-209, (1996)
[8]  
Wang Y.Q., Yan C.X., Jia P., Non-contact position precision detecting method of scanning mirror, Infrared and Laser Engineering, 41, 4, pp. 1057-1060, (2012)
[9]  
Zhang G.Y., Jiang H.L., Xu X.P., Et al., Laser dynamic testing method for swing angle of scanning mirror of infrared earth sensor, Acta Optica Sinica, 27, 5, pp. 875-880, (2007)
[10]  
Chen Q.S., Lu N.G., Yan B.X., Et al., Analysis to the methods for calculating the center position of Gaussian-distributed beam spot adopted in a laser alignment system, Computer Measurement & Control, 12, 5, pp. 486-488, (2004)