Ad hoc calibration of interferometric system for measuring nanometer-scale displacements induced by laser ultrasound

被引:0
作者
Kim, Younggue [1 ]
Yoon, Taeil [2 ]
Lee, Byeongha [1 ]
机构
[1] Gwangju Inst Sci & Technol GIST, Sch Elect Engn & Comp Sci, 123 Cheomdangwagi Ro, Gwangju 61005, South Korea
[2] Korea Univ, Inst Basic Sci, 145 Anam Ro, Seoul 02841, South Korea
关键词
Interferometry; Displacement measurement; Thickness measurement; Laser Ultrasound (LUS); Ultrasound detection; Fiber optic; CORNEAL THICKNESS; ERRORS; PHASE;
D O I
10.1016/j.optlastec.2024.111779
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Laser Ultrasound (LUS) is commonly used in many fields including thickness measurement and defect inspection. In a conventional LUS system, a piezo-based transducer (PZT) is generally used for detecting the ultrasound echo waves, which requires direct contact with a specimen and thus prolongs measurement time when any lateral scanning is necessary. We present a novel non-contact interferometric system based on a 3 x 3 optical fiber coupler. Even though the 3 x 3 interferometric system works stably at any operating point and allows quantitative measurements, it is generally known that careful calibration is necessary before main measurements. Experimentally, it was observed that the surface displacement, induced by the ultrasound wave of LUS, of a cornea phantom was so minute that averaging was necessary. In this study, we discovered that by using the multiple data sets acquired for averaging, we could obtain the system ad hoc characteristic ellipse without performing the conventional calibration process. Furthermore, by utilizing coherent average we could extract the displacement with a 0.14 nm sensitivity. We could also measure the thickness variation, induced by ocular pressure, of the cornea phantom with a resolution of 4.3 mu m by measuring the time of a round trip of the ultrasound wave. This straightforward system, composed solely of a 3 x 3 coupler, is expected to promise a compact and efficient solution to diverse applications.
引用
收藏
页数:10
相关论文
共 22 条
  • [1] PRECISION LASER-ULTRASONIC VELOCITY-MEASUREMENT AND ELASTIC-CONSTANT DETERMINATION
    AUSSEL, JD
    MONCHALIN, JP
    [J]. ULTRASONICS, 1989, 27 (03) : 165 - 177
  • [2] Train wheel diagnostics by laser ultrasonics
    Cavuto, A.
    Martarelli, M.
    Pandarese, G.
    Revel, G. M.
    Tomasini, E. P.
    [J]. MEASUREMENT, 2016, 80 : 99 - 107
  • [3] LASER-GENERATED ULTRASOUND - ITS PROPERTIES, MECHANISMS AND MULTIFARIOUS APPLICATIONS
    DAVIES, SJ
    EDWARDS, C
    TAYLOR, GS
    PALMER, SB
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1993, 26 (03) : 329 - 348
  • [4] Ameliorated 3 x 3 coupler-based demodulation algorithm using iteratively reweighted ellipse specific fitting
    Ge, Shaojie
    Zhang, Gang
    Ge, Qiang
    Xu, Linguang
    Wu, Xuqiang
    Yu, Benli
    [J]. OPTICS EXPRESS, 2024, 32 (02) : 1108 - 1122
  • [5] Non-contact ultrasonic techniques
    Green, RE
    [J]. ULTRASONICS, 2004, 42 (1-9) : 9 - 16
  • [6] Quadrature phase-shift error analysis using a homodyne laser interferometer
    Gregorcic, Peter
    Pozar, Tomaz
    Mozina, Janez
    [J]. OPTICS EXPRESS, 2009, 17 (18): : 16322 - 16331
  • [7] Measuring intraocular pressure-adjustments for corneal thickness and new technologies
    Herndon, Leon W.
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2006, 17 (02) : 115 - 119
  • [8] DETERMINATION AND CORRECTION OF QUADRATURE FRINGE MEASUREMENT ERRORS IN INTERFEROMETERS
    HEYDEMANN, PLM
    [J]. APPLIED OPTICS, 1981, 20 (19): : 3382 - 3384
  • [9] High precision displacement measuring interferometer based on the active modulation index control method
    Hoang, Anh Tu
    Vu, Thanh Tung
    Pham, Duc Quang
    Vu, Toan Thang
    Nguyen, Thanh Dong
    Tran, Van Huong
    [J]. MEASUREMENT, 2023, 214
  • [10] A NONCONTACT SCANNING SYSTEM FOR LASER ULTRASONIC DEFECT IMAGING
    HOYES, JB
    SHAN, Q
    DEWHURST, RJ
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 1991, 2 (07) : 628 - 634