Dynamic simulation for channel switching device of relay protection

被引:0
|
作者
Zhan, Rongrong [1 ]
Zhou, Chunxia [1 ]
Jin, Naizheng [2 ]
Ding, Huixia [1 ]
Zhu, Ma [2 ]
Zhan, Zhihua [1 ]
Yu, Yue [1 ]
机构
[1] Power System Dynamic Simulation Laboratory of SGCC Simulation Center, China Electric Power Research Institute, Beijing
[2] Zhejiang Shaoxing Power Bureau, Shaoxing
来源
Dianli Zidonghua Shebei/Electric Power Automation Equipment | 2014年 / 34卷 / 08期
关键词
Channel switching device; Communication; Dynamic simulation; Electric power systems; Models; Relay protection; Testing;
D O I
10.3969/j.issn.1006-6047.2014.08.028
中图分类号
学科分类号
摘要
The dynamic simulation model of primary system and relay protection channels is built, and its test items are designed. The corresponding test requirements are proposed and the channel switching device of relay protection are tested accordingly. The test result shows that, the tested channel switching device basically meets the technical requirements, but it may operate improperly when out-zone fault occurs immediately after it is repowered or its cache is adjusted together with the increased time delay of the backup channel. The reason of misoperation is analyzed and the solutions are given.
引用
收藏
页码:168 / 172
页数:4
相关论文
共 11 条
  • [1] He J., Li Y., Li B., Et al., Relay protection for UHV transmission lines part two disposition of relay protection, Automation of Electric Power Systems, 26, 24, pp. 1-6, (2002)
  • [2] Gu X., The transmission of relay protection signal taking advantage of optical fiber communication network, Telecommunication for Electric Power System, 25, 7, pp. 35-37, (2004)
  • [3] Li Z., Yang S., Yu D., Et al., Optical fiber communication applied in relay protection, Electric Power Automation Equipment, 27, 2, pp. 75-78, (2007)
  • [4] Zhu C., An Y., The technology principle and application of relay protection switching device, Shanxi Power, 12, 2, pp. 34-36, (2009)
  • [5] Wang Y., The application of smart channel switching device for the signal transmission of line protection and application of relay protection switching device, Network Telecom, 9, 9, pp. 58-59, (2007)
  • [6] Jin G., Error rate of channel and availability of remote channel, Telecommunications for Electric Power System, 2, pp. 45-46, (1999)
  • [7] Zhao C., Analysis on error rate increasing in main protection device channel of 500 kV line, Guizhou Electric Power Technology, 15, 3, pp. 52-54, (2012)
  • [8] Chen Q., Li R., Ma Q., Et al., The detection platform of relay protection channel in fiber diferential protection test, Power System Protection and Control, 37, 8, (2009)
  • [9] Xu Q., Zhang Y., Zhou D., Et al., Experiment-differential protection PSL603U, Power System Protection and Control, 38, 11, (2010)
  • [10] Pan J., Sun Y., Shen D., Et al., Comparision of fiber current differential protection synchronization schemes for smart substation, Electric Power Automation Equipment, 30, 9, pp. 101-104, (2010)