Measurement accuracy of heat meters: In situ Calibration of Heat Meters in Operation

被引:0
|
作者
Guntermann, Peter [1 ]
Rose, Jürgen [2 ]
Lederer, Thomas [2 ]
Dues, Michael [3 ]
Müller, Ulrich [4 ]
Duckwe, Andreas [5 ]
机构
[1] TÜV Rheinland Insitu Calibration GmbH, Cologne, Germany
[2] Physikalisch-Technische Bundesanstalt PTB, Berlin, Germany
[3] ILA GmbH, Jülich, Germany
[4] Optolution GmbH, Reinach, Switzerland
[5] Vattenfall Europe Wärme AG, Berlin, Germany
来源
关键词
Flowmeters - Flow measurement;
D O I
暂无
中图分类号
学科分类号
摘要
TÜV Rheinland, Cologne/Germany, has developed a new optical procedure in cooperation with two companies specializing in Laser optic measurement technology. The process enables the highly precise analysis of measurement accuracy of flow meters in situ without the need to interrupt operation. The method has been further developed in such a way that the access is now closed off with a pressure-tight sight glass, thereby creating an optical access. The results of the measurements carried out with the new procedure emphatically demonstrate the necessity of in situ inspections. Velocity profiles are recorded across the entire cross-section of the pipe. The flow rate is subsequently determined by integrating the velocity distribution. The measurement deviation of the flow meter in the installed state is determined by comparing the flow rate obtained by the LDV method with the value delivered by the device being inspected.
引用
收藏
页码:46 / 48
相关论文
共 50 条
  • [31] Electronic Heat Cost Meters.
    Hoentzsch, Von Christof
    Fernwarme international, 1986, 15 (06): : 367 - 374
  • [32] Demands on Small Heat Meters.
    Lutz, Horst
    Kroehner, Peter
    Fernwarme international, 1986, 15 (05): : 328 - 335
  • [33] Metrological support to domestic heat meters
    Vel't, ID
    MEASUREMENT TECHNIQUES, 2002, 45 (12) : 1282 - 1285
  • [34] CALIBRATION FACTOR OF HEAT FLUX METERS IN RELATION TO THERMAL CONDUCTIVITY OF SURROUNDING MEDIUM
    MOGENSEN, VO
    AGRICULTURAL METEOROLOGY, 1970, 7 (05): : 401 - &
  • [35] Experimental in-cavity radiative calibration of high-heat-flux meters
    Murthy, AV
    Fraser, GT
    DeWitt, DP
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2006, 20 (02) : 327 - 335
  • [36] EFFECT OF LASERS CHARACTERISTICS ON THE ACCURACY OF LASER METERS CALIBRATION
    Dlugunovich, V. A.
    Isaevich, A., V
    Kruplevich, E. A.
    Nasennik, L. N.
    DEVICES AND METHODS OF MEASUREMENTS, 2015, 6 (01): : 31 - 38
  • [37] Research of Measurement and Control System of Large-Diameter Heat Meters
    Xu Cuicui
    Huang Mingjian
    Zhu Jiang
    Tang Zhenjuan
    PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON TEST AUTOMATION & INSTRUMENTATION, VOLS 1 - 4, 2010, : 43 - 46
  • [38] Analysis of accuracy of measurement by Doppler laser meters
    Skeivalas, J
    Giniotis, V
    OPTICAL ENGINEERING, 2003, 42 (07) : 2025 - 2028
  • [39] Flow Sensor Error Analysis of Heat Meters after Long Term Operation
    Nikovski, Pl. I.
    Dinkova, M. G.
    Nachev, V. G.
    Maslinkov, Iv. M.
    2016 13TH INTERNATIONAL SCIENTIFIC-TECHNICAL CONFERENCE ON ACTUAL PROBLEMS OF ELECTRONIC INSTRUMENT ENGINEERING (APEIE), VOL 1, 2016, : 130 - 133
  • [40] Analysis of Methods of Improving Measurement Accuracy in Digital Velocity Meters in Nonstationary Operation.
    Andrushchuk, V.V.
    Izvestia vyssih ucebnyh zavedenij. Priborostroenie, 1980, 23 (03): : 23 - 28