Effect of ionic wind on the sample distribution in corona discharge ion mobility spectrometry

被引:0
作者
Wang, Jiyao [1 ]
Zhang, Chong [1 ]
Shi, Wenyan [1 ]
Ling, Yiyuan [1 ]
Wang, Xiaohao [1 ,2 ]
Ni, Kai [1 ,2 ]
机构
[1] Tsinghua Shenzhen Int Grad Sch, Div Adv Mfg, Shenzhen 518055, Peoples R China
[2] Tsinghua Univ, Dept Precis Instruments, State Key Lab Precis Measurement Technol & Instrum, Beijing 100084, Peoples R China
基金
中国博士后科学基金;
关键词
Ion mobility spectrometry; Corona discharge ionization; Ionic wind; Sample distribution; Electrolyte leakage detection; IONIZATION SOURCE; NEGATIVE CORONA; FLOW; DESIGN;
D O I
10.1016/j.talanta.2024.127282
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ionic wind generated during corona discharge (CD) can significantly influence the airflow field within Ion Mobility Spectrometry (IMS), yet its impact is often overlooked. This study delves into the impact of ionic wind on sample distribution, emphasizing the need to balance reactant ion density and ionic wind intensity, which leads to sample dilution. To mitigate this issue, an axial injection mode employing a hollow needle was proposed, thereby improving the sensitivity and recovery performance of CD-IMS. As a result, the limit of detection of dimethyl methylphosphonate (DMMP) monomer is lowered from 15 ppbv to 5 ppbv. Furthermore, this technique was successfully applied to the detection of lithium battery electrolyte leaks, with carbonate concentrations as low as 10 mg/L or 1 nL being detected within 5 s. Such findings underscore the technique's applicability for swift and sensitive monitoring of battery safety.
引用
收藏
页数:9
相关论文
共 43 条
  • [1] Detection of Chemical Warfare Agents with a Miniaturized High-Performance Drift Tube Ion Mobility Spectrometer Using High-Energetic Photons for Ionization
    Ahrens, Andre
    Allers, Maria
    Bock, Henrike
    Hitzemann, Moritz
    Ficks, Arne
    Zimmermann, Stefan
    [J]. ANALYTICAL CHEMISTRY, 2022, : 15440 - 15447
  • [2] Sensing Precursors of Illegal Drugs-Rapid Detection of Acetic Anhydride Vapors at Trace Levels Using Photoionization Detection and Ion Mobility Spectrometry
    Bocos-Bintintan, Victor
    Ghira, George-Bogdan
    Anton, Mircea
    Martiniuc, Aurel-Vasile
    Ratiu, Ileana-Andreea
    [J]. MOLECULES, 2020, 25 (08):
  • [3] Ion mobility spectrometer with orthogonal X-Ray source for increased sensitivity
    Bunert, Erik
    Reinecke, Tobias
    Kirk, Ansgar T.
    Bohnhorst, Alexander
    Zimmermann, Stefan
    [J]. TALANTA, 2018, 185 : 537 - 541
  • [4] Ambient ionization source based on a dielectric barrier discharge for direct testing of pharmaceuticals using ion mobility spectrometry
    Chantipmanee, Nattapong
    Furter, Jasmine S.
    Hauser, Peter C.
    [J]. ANALYTICA CHIMICA ACTA, 2022, 1195
  • [5] Review on Ion Mobility Spectrometry. Part 1: current instrumentation
    Cumeras, R.
    Figueras, E.
    Davis, C. E.
    Baumbach, J. I.
    Gracia, I.
    [J]. ANALYST, 2015, 140 (05) : 1376 - 1390
  • [6] A Novel Microwave-Induced Plasma Ionization Source for Ion Mobility Spectrometry
    Dai, Jianxiong
    Zhao, Zhongjun
    Liang, Gaoling
    Duan, Yixiang
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [7] Eiceman GA, 2014, ION MOBILITY SPECTROMETRY, 3RD EDITION, P1
  • [8] Fundamentals of ion mobility spectrometry
    Gabelica, Valerie
    Marklund, Erik
    [J]. CURRENT OPINION IN CHEMICAL BIOLOGY, 2018, 42 : 51 - 59
  • [9] Gas Chromatography/Mass Spectrometry As a Suitable Tool for the Li-Ion Battery Electrolyte Degradation Mechanisms Study
    Gachot, Gregory
    Ribiere, Perrine
    Mathiron, David
    Grugeon, Sylvie
    Armand, Michel
    Leriche, Jean-Bernard
    Pilard, Serge
    Laruelle, Stephane
    [J]. ANALYTICAL CHEMISTRY, 2011, 83 (02) : 478 - 485
  • [10] Direct analysis of pharmaceutical formulations from non-bonded reversed-phase thin-layer chromatography plates by desorption electrospray ionisation ion mobility mass spectrometry
    Harry, Emma L.
    Reynolds, James C.
    Bristow, Anthony W. T.
    Wilson, Ian D.
    Creaser, Colin S.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (17) : 2597 - 2604