A liquid chromatography - Tandem mass spectrometry method for determination of ocrelizumab in serum of patients with multiple sclerosis

被引:0
|
作者
Matlak, Patrik [1 ,2 ]
Brozmanova, Hana [1 ,2 ]
Sistik, Pavel [1 ,2 ]
Moskorova, Denisa [1 ,2 ]
Kacirova, Ivana [1 ,2 ]
Hradilek, Pavel [3 ,4 ]
Grundmann, Milan [1 ,2 ]
机构
[1] Univ Ostrava, Fac Med, Dept Clin Pharmacol, Syllabova 19, Ostrava 70300, Czech Republic
[2] Univ Hosp Ostrava, Inst Lab Med, Dept Clin Pharmacol, 17 Listopadu 1790-5, Ostrava 70852, Czech Republic
[3] Univ Hosp Ostrava, Dept Neurol, 17 Listopadu 1790-5, Ostrava 70852, Czech Republic
[4] Univ Ostrava, Fac Med, Dept Clin Neurosci, Syllabova 19, Ostrava 70300, Czech Republic
关键词
Ocrelizumab; Multiple sclerosis; Serum; Antibodies; Liquid chromatography; Mass spectrometry; INTERNAL STANDARD; ELISA; QUANTIFICATION; NATALIZUMAB; ALEMTUZUMAB; VALIDATION; INFLIXIMAB; ANTIBODY; PLASMA;
D O I
10.1016/j.talanta.2024.127111
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ocrelizumab is a second generation recombinant humanized IgG1 monoclonal antibody used for the treatment of multiple sclerosis that selectively target B cells expressing the CD20 antigen. This study aimed to develop and validate a UPLC-MS/MS method for quantification of ocrelizumab in human serum, which can be used in clinical applications for therapeutic drug monitoring. The analysis of ocrelizumab was performed using a bottom-up approach on a liquid chromatography coupled to tandem mass spectrometry detection. The method involved immunoglobulin precipitation with cold methanol followed by peptide digestion with trypsin. The resulting specific peptides were separated on an Acquity UPLC BEH C18 column at 55 degrees C using gradient elution. The method was validated according to European Medicines Agency (EMEA) guidelines and demonstrated intra- and inter-assay precision with coefficients of variation ranging from 1.6 % to 6.1 % and accuracies between 90.2 % and 107.2 %. Stability testing, including autosampler, long-term and freeze-thaw stability, showed no more than 15 % variation. The method was successfully applied to 169 patient samples, revealing ocrelizumab concentrations ranging from 0.5 to 21.8 mg/L in patients on 6-month dosing regimen and 20.5-65.0 mg/L in 16 patients receiving an initial two-week dose of 300 mg. The newly developed UPLC-MS/MS method met all criteria for accuracy, precision and stability, confirming its suitability for clinical use in monitoring ocrelizumab levels in multiple sclerosis patients.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Determination of hyoscyamine and scopolamine in serum and urine of humans by liquid chromatography with tandem mass spectrometry
    Konishi, Tomohiko
    Akaki, Kouichi
    Hatano, Kazuhiro
    JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 2008, 49 (04): : 266 - 271
  • [42] Development and validation of a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the determination of ribavirin in human plasma and serum
    Shou, WZ
    Bu, HZ
    Addison, T
    Jiang, XY
    Weng, ND
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 29 (1-2) : 83 - 94
  • [43] Rapid determination of domoic acid in serum and urine by liquid chromatography-electrospray tandem mass spectrometry
    Tor, ER
    Puschner, B
    Whitehead, WE
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2003, 51 (07) : 1791 - 1796
  • [44] Development of a liquid chromatography tandem mass spectrometry method for the simultaneous determination of zearalenone, deoxynivalenol and their metabolites in pig serum
    Brezina, Ulrike
    Valenta, Hana
    Rempe, Inga
    Kersten, Susanne
    Humpf, Hans-Ulrich
    Daenicke, Sven
    MYCOTOXIN RESEARCH, 2014, 30 (03) : 171 - 186
  • [45] Development and Validation of a Hydrophilic Interaction Liquid Chromatography Tandem Mass Spectrometry Method for the Determination of Asparagine in Human Serum
    Lu, Haoyang
    Zeng, Xiaoyun
    Yu, Lihua
    Wang, Zhanzhang
    Lin, Danna
    Ni, Xiaojia
    Shang, Dewei
    Zhang, Ming
    Hu, Jinqing
    Deng, Shuhua
    Zhu, Xiuqing
    Chen, Yuqing
    Xie, Huanshan
    Yang, Lihua
    Wen, Yuguan
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 2020
  • [46] Applicability of Adduct Detection in Liquid Chromatography-Tandem Mass Spectrometry
    Dziadosz, Marek
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2015, 38 (18) : 1671 - 1674
  • [47] DETERMINATION OF ANTIBIOTIC FOSFOMYCIN IN CHICKEN SERUM BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Dieguez, Susana
    Soraci, Alejandro
    Tapia, Ofelia
    Carciochi, Ramiro
    Perez, Denisa
    Harkes, Roberto
    Romano, Omar
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2011, 34 (02) : 116 - 128
  • [48] Development of a liquid chromatography tandem mass spectrometry method for the simultaneous determination of zearalenone, deoxynivalenol and their metabolites in pig serum
    Ulrike Brezina
    Hana Valenta
    Inga Rempe
    Susanne Kersten
    Hans-Ulrich Humpf
    Sven Dänicke
    Mycotoxin Research, 2014, 30 : 171 - 186
  • [49] A rapid and simple liquid chromatography-tandem mass spectrometry method for the measurement of testosterone, androstenedione, and dehydroepiandrosterone in human serum
    Xu, Wenjuan
    Li, Huijun
    Guan, Qing
    Shen, Ying
    Cheng, Liming
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2017, 31 (05)
  • [50] Liquid chromatography-electro spray tandem mass spectrometry method for determination of indapamide in serum for single/multiple dose bioequivalence studies of sustained release formulations
    Albu, F
    Georgita, C
    David, V
    Medvedovici, A
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 816 (1-2): : 35 - 40