Performance study of a two phase closed thermosyphon was experimentally investigated. The experiments were carried out for different filling ratios of 30 to 90% with input heat transfer rates of 0 to 1000 W and for various working fluids such as distilled water, ethanol, methanol and acetone. Investigations were focused to find the influence of the filling ratio, maximum heat transport capability for various working fluids in a vertical two phase closed thermosyphon. The maximum heat transport capability was found to be high for water compared to other fluids such as ethanol, methanol and acetone, at the operating temperatures higher than 40°C. © 2010 Asian Network for Scientific Information.
引用
收藏
页码:413 / 418
页数:5
相关论文
共 50 条
  • [31] Effects of nanofluids on heat transfer characteristics of a two-phase closed thermosyphon
    Kamyar, A.
    Ong, K. S.
    Saidur, R.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 65 : 610 - 618
  • [32] Enhancing heat transfer performance of a two-phase closed thermosyphon using a polymer-coated hydrophobic condenser
    Seo, Donghyun
    Park, Jinsoo
    Shim, Jaehwan
    Nam, Jeonghyeon
    Shin, Dong Hwan
    Nam, Youngsuk
    Lee, Jungho
    APPLIED THERMAL ENGINEERING, 2021, 196
  • [33] Thermal performance enhancement and optimization of two-phase closed thermosyphon with graphene-nanoplatelets coatings
    Ng, Ving Onn
    Yu, Hao
    Wu, Heng An
    Hung, Yew Mun
    ENERGY CONVERSION AND MANAGEMENT, 2021, 236
  • [34] Influence of system pressure on the boiling heat transfer coefficient in a closed two-phase thermosyphon loop
    Khodabandeh, R
    Palm, B
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2002, 41 (07) : 619 - 624
  • [35] The two-phase closed tubular cryogenic thermosyphon
    Bolozdynya, A. I.
    Dmitrenko, V. V.
    Efremenko, Yu. V.
    Khromov, A. V.
    Shafigullin, R. R.
    Shakirov, A. V.
    Sosnovtsev, V. V.
    Tolstukhin, I. A.
    Uteshev, Z. M.
    Vlasik, K. F.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 80 : 159 - 162
  • [36] Enhanced thermal performance of a thermosyphon for waste heat recovery: Microporous coating at evaporator and hydrophobic coating at condenser
    Kim, Yeonghwan
    Kim, Jin Sub
    Shin, Dong Hwan
    You, Seung M.
    Lee, Jungho
    APPLIED THERMAL ENGINEERING, 2020, 175
  • [37] Effect of aspect ratio and filling ratio on thermal performance of an inclined two-phase closed thermosyphon
    Emami, M. R. Sarmasti
    Noie, S. H.
    Khoshnoodi, M.
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY TRANSACTION B-ENGINEERING, 2008, 32 (B1): : 39 - 51
  • [38] Determination of the operation range of a vertical two-phase closed thermosyphon
    Jiao, B.
    Qiu, L. M.
    Gan, Z. H.
    Zhang, X. B.
    HEAT AND MASS TRANSFER, 2012, 48 (06) : 1043 - 1055
  • [39] Heat transfer performance of a two-phase closed thermosyphon with different inclination angles based on the core-tube monitoring
    Wang, Yingmei
    Wang, Xi
    Wang, Juncheng
    Liu, Yongheng
    Chen, Ji
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 42
  • [40] EXPERIMENTAL STUDY ON HEAT TRANSFER CHARACTERISTICS OF A MODIFIED TWO-PHASE CLOSED THERMOSYPHON
    Aghel, Babak
    Rahmi, Masoud
    Almasi, Saeed
    THERMAL SCIENCE, 2017, 21 (06): : 2481 - 2489