Two-Way Shear Strength of GFRP-Reinforced Precast Concrete Box Culverts under Vertical Concentrated Loading

被引:0
|
作者
Elnady, Ahmed [1 ]
Mousa, Salaheldin [1 ]
Benmokrane, Brahim [2 ,3 ,4 ]
机构
[1] Univ Sherbrooke, Dept Civil & Bldg Engn, Sherbrooke, PQ J1K 2R1, Canada
[2] Univ Sherbrooke, Dept Civil & Bldg Engn, Civil Engn & Tier 1 Canada Res, Sherbrooke, PQ J1K 2R1, Canada
[3] Univ Sherbrooke, Dept Civil & Bldg Engn, Adv Compos Mat Civil Struct & Ind Res, Sherbrooke, PQ J1K 2R1, Canada
[4] Univ Sherbrooke, Dept Civil & Bldg Engn, Innovat FRP Reinforcement Sustainable Concrete Str, Sherbrooke, PQ J1K 2R1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Precast concrete box culverts; Glass fiber-reinforced polymer; Bedding material; Two-way shear failure; Design codes; POLYMER BARS; BEHAVIOR; DESIGN;
D O I
10.1061/JCCOF2.CCENG-4785
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The purpose of this study was to investigate the two-way shear strength of precast concrete box culverts reinforced with glass fiber-reinforced polymer (GFRP) bars. The investigations included testing four full-scale specimens reinforced with GFRP bars under truck wheel load in accordance with current Canadian design codes. The load was applied to the top slab at three different distances: d (effective depth), 1.5d, and 2.5d from the tip of the haunch to the edge of the load plate. One of the specimens was placed and tested on an aggregate bedding material instead of the rigid floor of the test laboratory. Following experimental testing, a theoretical study was conducted to evaluate experimental shear strength to predicted values using different provisions of several North American and international design standards. Two-way shear failure in the top slab occurred in all tested box culverts, indicating that GFRP-reinforced concrete box culverts are critical in shear under traffic wheel loads. The behavior of the tested box culverts was significantly affected by changing the load location or testing the specimen on an aggregate bedding material. On the other hand, the available two-way shear equations conservatively predicted the two-way shear strength of the top slab of the box culverts. Moreover, the two-way shear action equation used in the Canadian standards considers only the cracking strength of concrete. Therefore, an equation has been proposed to consider the characteristics of the GFRP bars and shear span to effective depth ratio. The proposed equation accurately predicted the two-way shear strength and may be considered in future provisions. Finally, the findings demonstrated the feasibility and efficiency of using GFRP bars as internal reinforcement in concrete box culverts.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Experimental study on punching shear bearing capacity of BFRP bars reinforced two-way concrete slabs under concentrated load
    Zhang, Yakun
    Zhu, Haitang
    Gao, Danying
    Li, Chuanchuan
    STRUCTURES, 2025, 71
  • [32] Effect of design strength parameters of conventional two-way singly reinforced concrete slab under concentric impact loading
    Anas, S. M.
    Alam, Mehtab
    Umair, Mohammad
    MATERIALS TODAY-PROCEEDINGS, 2022, 62 : 2038 - 2045
  • [33] Numerical and statistical analysis of parameters that influence the shear strength of reinforced concrete two-way slabs
    de Oliveira, Jackeline Santos
    Delalibera, Rodrigo Gustavo
    MATERIA-RIO DE JANEIRO, 2022, 27 (02):
  • [34] Punching of column-supported two-way concrete slabs reinforced with GFRP
    Ospina, CE
    Alexander, SDB
    Cheng, JJR
    ADVANCED COMPOSITE MATERIALS IN BRIDGES AND STRUCTURES, 2000, : 323 - 330
  • [35] A strength and deformation model for prestressed lightweight concrete slabs under two-way shear
    Deifalla, A.
    ADVANCES IN STRUCTURAL ENGINEERING, 2021, 24 (14) : 3144 - 3155
  • [36] Validity of SDOF Models for Analyzing Two-Way Reinforced Concrete Panels under Blast Loading
    El-Dakhakhni, W. W.
    Mekky, W. F.
    Rezaei, S. H. Changiz
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2010, 24 (04) : 311 - 325
  • [37] Experimental Investigation of Two-Way Concrete Slabs Reinforced by Perforated Steel Plates Under Concentrated Load
    Al-zahid, Ali Adnan
    Alwash, Nameer A.
    ENGINEERING TRANSACTIONS, 2022, 70 (01): : 67 - 75
  • [38] A new formula of punching shear strength for fiber reinforced polymer (FRP) or steel reinforced two-way concrete slabs
    Ju, Minkwan
    Ju, Jiann-wen Woody
    Sim, Jongsung
    COMPOSITE STRUCTURES, 2021, 259
  • [39] Testing of Large-Scale Two-Way Concrete Slabs Reinforced with GFRP Bars
    Dulude, C.
    Ahmed, E.
    El-Gamal, S.
    Benmokrane, B.
    ADVANCES IN FRP COMPOSITES IN CIVIL ENGINEERING, 2010, : 287 - 291
  • [40] Shear behavior of precast concrete wall structure based on two-way hollow-core precast panels
    Xiong, Chen
    Chu, Mingjin
    Liu, Jiliang
    Sun, Zhijuan
    ENGINEERING STRUCTURES, 2018, 176 : 74 - 89